Soehnle Microscope Magnifier 3011 User Manual

Operating Manual 3011  
Digital indicator 3011  
Operating Manual Digital Indicator 3011  
Version V0.1  
Stand: 06.09.07  
Page 1 of 8  
Subject to technical modifications. Drafts are protected according to §823 BGB: Copy, duplication or circulation only with explicit approval.  
Soehnle Professional GmbH & Co. KG  
|
P.O. Box 1308  
|
D-71536 Murrhardt | Telephone +49 (0) 7192 / 9319 – 0  
|
4.Y-8328  
 
Operating Manual 3011  
Electronic nameplate type 3011  
By pressing the keys  
and  
, the electronic nameplate is indicated.  
T
With the arrow keys (  
), the electronic nameplate as well as the  
T F  
serial number and calibration counter of the measuring point can be indicated on the  
display.  
The indication of the electronic nameplate is terminated by pressing the key  
For a one-range scale, the parameters of the other range are not applicable.  
.
Indication  
Stepps  
Parameters  
Display  
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
9.  
Calibration counter  
Type  
Year  
Serial number  
Ident- Chip  
Max of range 1  
Min of range 1  
e of range 1  
Max of range 2  
Min of range 2  
e of range 2  
E 2  
T 2880  
Y 07  
1234  
Id 1  
¯ 10,00kg  
_
0,20kg  
0,01kg  
¯ 20,00kg additionally sign for range 2  
E
10.  
11.  
_
E
0,40kg additionally sign for range 2  
0,02kg additionally sign for range 2  
For non-approvable scales, “d“ instead of “E“ is indicated.  
Operating Manual Digital Indicator 3011  
Version V0.1  
Stand: 06.09.07  
Page 3 of 8  
Subject to technical modifications. Drafts are protected according to §823 BGB: Copy, duplication or circulation only with explicit approval.  
Soehnle Professional GmbH & Co. KG  
|
P.O. Box 1308  
|
D-71536 Murrhardt | Telephone +49 (0) 7192 / 9319 – 0  
|
4.Y-8328  
 
Operating Manual 3011  
SWITCH On/Off Type 3011  
Switch the indicator on/off via the ON/OFF key.  
While switching on, the scale is zeroed. If the scale is switched on outside the zero range  
at power-on, the scale indicates an error message:  
_0_ = Measuring value below zero limit  
_ _  
0 = Measuring value above zero limit  
The application is switched off to avoid the cause for under/overload before the next  
switch on. The zero range at power-on can be skipped by pressing the zero key during  
the switch on routine. The last saved zero point is accepted.  
The active measuring point is indicated as flag on the display. Switchover to another  
measuring point is realised by pressing the Info and Print key on the keyboard.  
Zero range limits at power-on:  
Approvable: Zero range at power-on 20% of maximum, default –5% to +15% of maximum  
Non-approvable: Zero range at power-on –99% to +99% of maximum  
Behaviour at power failure: the scale returns in the last saved state.  
At power-on (warm or cold starting), the last used program is activated.  
Operating Manual Digital Indicator 3011  
Version V0.1  
Stand: 06.09.07  
Page 4 of 8  
Subject to technical modifications. Drafts are protected according to §823 BGB: Copy, duplication or circulation only with explicit approval.  
Soehnle Professional GmbH & Co. KG  
|
P.O. Box 1308  
|
D-71536 Murrhardt | Telephone +49 (0) 7192 / 9319 – 0  
|
4.Y-8328  
 
Operating Manual 3011  
Zeroing Type 3011  
Zeroing via the zero key.  
Zeroing approvable: -1 to +3% according to Approval Directive.  
Zero range non-approvable: Same range as set zero range limits at power-on.  
The display indicates after keypress  
at <-1% message Err 5  
at > 3% message Err 5  
Zero tracking: in the setting mode, the zero tracking can be switched on or off (on = 0,5  
d/sec at standstill).  
Operating Manual Digital Indicator 3011  
Version V0.1  
Stand: 06.09.07  
Page 5 of 8  
Subject to technical modifications. Drafts are protected according to §823 BGB: Copy, duplication or circulation only with explicit approval.  
Soehnle Professional GmbH & Co. KG  
|
P.O. Box 1308  
|
D-71536 Murrhardt | Telephone +49 (0) 7192 / 9319 – 0  
|
4.Y-8328  
 
Operating Manual 3011  
Tara functions Type 3011  
The following tare function is available as standard fort he indicator 3011 to save  
weighing data in the tare memory:  
1. Manual tare  
Keypad management:  
Manual tare: Via the key "Tara"  
on the membrane keyboard.  
T
Manual tare: by pressing the tare key. The tare value is saved, the weight indication is at  
zero, switchover from gross to net is realised => “net” in display via a red LED. If the scale  
is discharged, the tare weight shows a negative sign. Pressing the tare key again  
overwrites the existing value, which means that a newly placed tare weight on the scale is  
saved or the discharged scale with a negative tare weight on the display is zeroed.  
Delete tare memory:  
Pres the zero key.  
Operating Manual Digital Indicator 3011  
Version V0.1  
Stand: 06.09.07  
Page 6 of 8  
Subject to technical modifications. Drafts are protected according to §823 BGB: Copy, duplication or circulation only with explicit approval.  
Soehnle Professional GmbH & Co. KG  
|
P.O. Box 1308  
|
D-71536 Murrhardt | Telephone +49 (0) 7192 / 9319 – 0  
|
4.Y-8328  
 
Operating Manual 3011  
X10 DISPLAY Type 3011  
The tenfold higher resolution on the display is activated by pressing the keys “PRINT”  
and “-0-“.  
If the scale is calibrated approvable, the tenfold higher resolution is indicated after a  
keypress for 5 seconds or as long as the keys are hold.  
Operating Manual Digital Indicator 3011  
Version V0.1  
Stand: 06.09.07  
Page 7 of 8  
Subject to technical modifications. Drafts are protected according to §823 BGB: Copy, duplication or circulation only with explicit approval.  
Soehnle Professional GmbH & Co. KG  
|
P.O. Box 1308  
|
D-71536 Murrhardt | Telephone +49 (0) 7192 / 9319 – 0  
|
4.Y-8328  
 
Operating Manual 3011  
PRINT Type 3011  
An optional interface RS232 must be assembled in the digital indicator 3011 for the  
function „Print“.  
The stored print template is send via the interface by pressing the print key.  
Print template design and print conditions are realised via the service program.  
Operating Manual Digital Indicator 3011  
Version V0.1  
Stand: 06.09.07  
Page 8 of 8  
Subject to technical modifications. Drafts are protected according to §823 BGB: Copy, duplication or circulation only with explicit approval.  
Soehnle Professional GmbH & Co. KG  
|
P.O. Box 1308  
|
D-71536 Murrhardt | Telephone +49 (0) 7192 / 9319 – 0  
|
4.Y-8328  
 

Socket Mobile Personal Computer 650RX User Manual
Sony Digital Camera 4 187 045 111 User Manual
Sony MiniDisc Player MZ N1 User Manual
Sony Projection Television KP 51WS520 User Manual
Sony Projector KP 61HS10 User Manual
Sony Speaker System DAV S400 User Manual
Speco Technologies Security Camera CVC 627B User Manual
Sunbeam Fryer 3243 User Manual
Tanaka Trimmer TBC 280PF User Manual
Targus Digital Camera USB 20 WebCam User Manual