Tamarack Technologies Ventilation Hood GH02 User Manual

GH.02  
GHOST  
WHOLE hoUSE VENTILATOR  
PRODUCT MANUAL & INSTALLATION GUIDE  
Serial Number  
Date of Purchase  
Point of Purchase  
The serial number is located on the shipping carton  
and on a label affixed to an insulated door.  
Unpacking your GHOST:  
When you have unpacked your GHOST  
carefully you will find the following:  
One (1) GHOST  
One (1) White Metal Grille w/(6) Screws  
One (1) Hand Held Remote Transmitter  
One (1) Remote Receiver w/ line cord & interconnect cable  
The Best Location for your GHOST: The GHOST should be installed in your attic in a central location within  
your home. Above a central hallway or at the top of a stairwell will provide the best airflow.  
Make sure that there aren’t any pipes, wires, rafters or air conditioning or heating ducts running through  
the space where the GHOST will be installed. The GHOST can NOT be mounted vertically.  
Make sure that you have adequate exhaust area out of your attic. This can be accomplished with  
a combination of roof, ridge or gable end vents. The GHOST requires a minimum of 9 square feet of attic exhaust area.  
If your home has an engineered roofing system, care should be taken that the GHOST will fit within the truss layout.  
READ AND SAVE THESE INSTRUCTIONS  
WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING:  
Use this unit in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.  
Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being  
switched on accidentally. When the service disconnecting cannot be locked, securely fasten a prominent warning  
device, such as a tag, to the service panel.  
When cutting or drilling into wall or ceiling, do not damage electrical wiring or other hidden utilities.  
Never place a switch where it can be reached from a tub or shower.  
Do not use this fan over a tub or shower.  
Do not use this fan over cooking appliances.  
WARNING: To Reduce The Risk of Fire or Electric Shock, Do Not Use This Fan With Any Solid-State Speed Control Device.  
CAUTION: For General Ventilation Use Only. Do Not Use To Exhaust Hazardous Or Explosive Materials And Vapors  
CAUTION: This unit has an unguarded impeller. Do Not Use in Locations Readily Accessible to People or Animals.  
Tamarack Technologies, Inc.• 320 Main Street • Buzzards Bay, MA 02532  
508-759-4660 • 800-222-5932 • Fax 508-759-6001 • www.tamtech.com  
 
6. Rotate the upper housing until it lines up with the  
lower housing. Make sure the edges of the two hous-  
ings mate all the way around the GHOST (Figure 6)  
and then pull the black attachment handles down over  
their attachment posts (Figure 7).  
7. If desired, secure the GHOST to the top of the joists.  
8. Plug the connector from the GHOST into the Control  
Box. Plug the Control Box into an unswitched,  
grounded receptacle.  
Figure 6.  
9. Install the ceiling grille (screws provided).  
10. Check the unit for proper operation:  
Turn the unit on - it will take 30 seconds for the  
doors to open.  
Fan starts - the fan should start and run  
smoothly.  
Be sure at least one window is open when the  
fan is operating.  
Figure 7.  
WARNING: State and local  
electrical codes may require  
that the GHOST be installed  
specificationS  
wiring  
Electrical:  
by a licensed electrician.  
Check with your local code  
officials before installing.  
Be sure to turn off power  
before wiring the GHOST  
Whole House fan.  
115 VAC 60Hz  
Voltage  
Power  
(High Speed) 450 Watts  
(Low Speed) 340 Watts  
Air Flow  
High Speed 3400 CFM  
Low Speed 1900 CFM  
30 second Door Cycle Time  
(Open-Close)  
Operation  
MODEL GH: R-22  
MODEL GHD: R-38  
Insulation Value of  
Closed Doors  
Whole House Ventilator: 48 Lbs.  
Shipping: 67 Lbs.  
Weights  
Top Housing  
26 1/4” long x 26” W x 14 1/8’ H  
25 7/8” long” x 29 1/2” W  
x 13 5/8” H  
Lower Housing  
 
GHOST  
WHOLE hoUSE VENTILATOR  
PRODUCT MANUAL & INSTALLATION GUIDE  
Troubleshooting  
Programming the  
If the wireless fails to activate the fan try the following:  
GHOST Remote  
• The battery may need replacing. The transmitter uses a type A23/12V  
battery. Remove the back plate from the transmitter and remove the battery.  
Following the markings, replace the battery and secure the back plate  
to the transmitter.  
• Check that all the connections are tight and that there is power to the outlet.  
• If wall switches are also used to control the Ghost, check to see that they  
are not in use and overriding the hand held transmitter.  
• The hand transmitter and the receiver may not be communicating. Try to  
reestablish communication by following the instruction further along in  
the Troubleshooting section of this manual.  
• Remove the cover from the  
black box  
• Push the Learn button  
momentarily…you should  
hear a “beep”  
• Push the ON button on the  
Hand Held Remote...  
you should hear “clicking”  
• The doors on the GHOST  
should start to open  
If the doors are open but the fan is not rotating try the following:  
• Check the electrical connection between the upper and lower sections  
• Turn off the power and check for foreign matter blocking fan rotation  
LIMITED WARRANTY If, within the period of three years from the date of purchase, the GHOST (the Product) is defective or malfunctions  
in normal home use, Tamarack Technologies, Inc. will repair or replace the Product, at its discretion. Customer is responsible for shipping charges.  
NOTE: Some states codes require fans to be hardwired. HARDWIRING THE GHOST WILL NOT VOID WARRANTY PROVIDING THE WIRING IS  
PERFORMED BY A LICENSED ELECTRICIAN.  
CONDITIONS, EXCLUSIONS, AND LIMITATIONS-This Warranty is subject to the following conditions, exclusions and  
limitations: THIS WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM INSTALLATION, OPERATION OR MAINTENANCE THAT HAS BEEN  
UNDERTAKEN OTHER THAN IN ACCORDANCE WITH THE INSTRUCTIONS. THIS WARRANTY DOES NOT COVER PROBLEMS RESULTING FROM  
DEFECTS IN OR CAUSED BY ASSOCIATED EQUIPMENT (FURNACES, SOLARIA, ETC.); FROM REPAIRS OR MODIFICATIONS ATTEMPTED BY  
PERSONS OTHER THAN TAMARACK TECHNOLOGIES, INC.; FROM ABUSE, ACCIDENTAL OR SHIPPING DAMAGE OR ACTS OF GOD. THIS WAR-  
RANTY DOES NOT APPLY TO THE PRODUCT USED OUTSIDE THE UNITED STATES, ITS TERRITORIAL POSSESSIONS, AND CANADA. EXCEPT  
AS SET FORTH ABOVE, NO EXPRESS OR IMPLIED WARRANTY IS GIVEN OR AUTHORIZED BY TAMARACK TECHNOLOGIES, INC. AND ALL  
OTHER SUCH WARRANTIES ARE EXPRESSLY DISCLAIMED. ANY WARRANTY OR MERCHANTABILITY OF FITNESS FOR ANY PARTICULAR PUR-  
POSE SHALL BE LIMITED TO THE WARRANTY HEREUNDER. MOREOVER, ANY LIABILITY OF TAMARACK TECHNOLOGIES, INC. FOR THE PROD-  
UCT SHALL BE LIMITED TO THE REPLACEMENT VALUE OF THE PRODUCT. IN NO EVENT SHALL TAMARACK TECHNOLOGIES, INC. BE LIABLE  
FOR ANY INCIDENTAL DAMAGES OR FOR ANY CONSEQUENTIAL PROPERTY OR COMMERCIAL DAMAGES, IRRESPECTIVE OF THE CAUSE  
THEREOF, OCCURRING EITHER DURING OR AFTER THE WARRANTY PERIOD, INCLUDING WITHOUT LIMITATION ANY DAMAGES TO ANY PART  
OF A BUILDING OR ITS CONTENTS.  
NOTE: SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES AND SOME STATES  
DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE LIMITATIONS OR EXCLUSIONS MAY NOT APPLY  
TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS AND YOU MAYALSO HAVE OTHER RIGHTS THAT VARY FROM STATE TO STATE.  
320 Main Street • Buzzards Bay, Ma 02532  
508-759-4660 / 800-222-5932 / Fax 508-759-6001  
 

Sharp Doll CD SW200E User Manual
Sharp Microwave Oven R 754M User Manual
SIIG Computer Drive 04 0725A User Manual
Silvercrest Hair Care Product SHGR 75 A1 User Manual
Soleus Air Electric Heater HM2 15 32 User Manual
Sony Personal Computer PCV 9913 User Manual
Sony Projection Television KF 60DX100 User Manual
Sony Server VGF HS1 User Manual
Speed Queen Washer Dryer AWM472W2 User Manual
StarTechcom Computer Hardware PCIVGA7 User Manual