Two-Ring Door Instructions
Installation Manual
PNEG-301
Date: 01-22-08
PNEG-301
Table of Contents
Contents
Chapter 1 Installation ..........................................................................................................................................4
Inner Door Auger Hood (Optional) ..................................................................................................... 8
PNEG-301 Two-Ring Door
3
1. Installation
Two-Ring Door Installation
Before beginning the installation, be sure the correct door has been received.
Figure 1A
1. Remove inner door panels and outer door cover. Apply two rows of rope caulk around all four (4)
door flanges: On vertical flanges, one row of caulk should be applied between the two vertical rows
of bolts and the other row of caulk should be applied between the door frame and the first row of
vertical bolts. On the horizontal flanges, a row of caulk should be applied on each side of the row
of bolts.
NOTE: For the 2.66" corrugation, all caulk is applied to the outside of the door flanges and the door
flanges are applied to the inside of the sidewall.
NOTE: For 4.00" corrugation: the top of the door frame goes to the inside of the sidewall and the
bottom of the door frame goes to the outside of the sidewall. Therefore, depending upon
location and overlap, caulk will be applied on either the inside or the outside of the door
With inner door panels and outer door cover removed, set door frame into opening. Insert several
2. Reinstall inner door panels at original locations. Close latch bars to lock panels in place. Be sure
that panels are fully seated over all bearing pins. Install inner panel hinge assemblies per
instructions in manual PNEG-301 with hinges. NOTE: Do not distort door frame with use of
alignment or drift punches - if necessary, drill or ream holes to insert bolts in door frame. Now
tighten frame bolts starting at center and working toward top and bottom on each side. (On
2.66" corrugation bins, be sure bottom ring of sidewall is installed before tightening these bolts.)
3. To make panels easier to operate, loads on pins should be uniform. To do this, loosen all bearing
pin bolts with inner panels latched. Then, retighten all bearing pin bolts.
4
PNEG-301 Two-Ring Door
1. Installation
4. If some latch bars are loose or require excessive force to lock, loosen hex socket capscrews and
adjust in or out until latch bars operate smoothly. Check that the panels are fully seated over all
bearing pins.
5. Re-install outer cover. Adjust outer door hinges and latches as required.
Hook retaining bracket over lower latch mount and position the door hold back against bin wall in
a valley. Drill a 3/8" hole through the bin wall and bolt the door hold back to the bin.
PNEG-301 Two-Ring Door
5
1. Installation
Parts List for Two-Ring Doors
PART #
QTY
KEY
12'-27' and 30'-60' BIN DIAMETER
2.66" and 4.00" CORR.
WD-039
DESCRIPTION
12'-27' and 30'-60'
BIN DIAMETER
1
2
OUTER DOOR COVER
1
WD-2854
OUTER COVER LATCH BRACKET
OUTER COVER HINGE BRACKET
DOOR COVER BRACE SECTION
DOOR RETAINER
2
3
WD-225
2
4
WD-035
4
5
WD-033
3
6
WD-6124
OUTER COVER LATCH MOUNT BASE
OUTER COVER HINGE BASE
BOTTOM INNER DOOR HINGE
MIDDLE INNER DOOR HINGE
TOP INNER DOOR HINGE
2
7
WD-6066
2
8
WD-6055
1
9
WD-6056
2
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
WD-6054
1
S-4380
RUBBER TRIM SEAL STRIP
LATCH BAR
2-1/4 FT.
WD-6039
3
3
WD-6037
INNER PANEL LATCH - RIGHT HAND
INNER PANEL LATCH - LEFT HAND
LATCH BUSHING
WD-6038
3
WD-6040
6
S-8648
1/2" X 1-1/2" HEX SOCKET CAPSCREW
LONG BEARING PIN
6
WD-6079
38
6
WD-6125
INNER PANEL REINFORCING ANGLE
BOTTOM INNER DOOR PANEL
MIDDLE INNER DOOR PANEL
TOP INNER DOOR PANEL
WD-6128
1
WD-6127
1
WD-6126
1
WD-6028
BOTTOM INNER DOOR PORT HOLE COVER
INNER DOOR HINGE STRAP
DOOR HOLD BACK BRACKET
DOOR HOLD BACK EXTENSION
1
WD-6053
6
WD-1302
1
WD-6110
1
PNEG-301 Two-Ring Door
7
1. Installation
Inner Door Auger Hood (Optional)
12' (3.66 m) - 24' (7.32 m) Diameters Only
Figure 1C
Remove bolts, lock washers and nuts along each side of large square opening. Position auger shield as
shown in Figure 1C and bolt to underside of top angle with bolt heads under shield. Replace bolts, lock
washers and nuts along sides of opening.
Unloading grain through door opening may cause grain bin failure if not done
properly. Unloading directly through the door opening should be limited to grain
bins no larger than 24' (7.32 m) diameter and grain depths no greater than
18' (5.49 m).
Unloading from the door opening should be done only with use of an auger
hood with the auger inserted through the opening to the center of the grain bin.
Bin Step (Optional)
Figure 1D
8
PNEG-301 Two-Ring Door
1. Installation
Door Hinge Installation Instructions
Figure 1E
Viewed from the Inside of the Bin
During door frame and inner panel installation, install hinges in position as shown. (NOTE: Head of bolt
with neoprene washer to be on the outside of the bin.) Attach hinge frame half using only existing frame
to sidewall bolts. All frame to sidewall bolts must be installed.
PNEG-301 Two-Ring Door
9
This equipment shall be installed in accordance with
the current installation codes and applicable
regulations which should be carefully followed in all
cases. Authorities having jurisdiction should be
consulted before installations are made.
GSI Group
1004 E. Illinois St.
Assumption, IL 62510-0020
Phone: 1-217-226-4421
Fax: 1-217-226-4420
Copyright © 2007 by GSI Group
Printed in the USA
|