Grizzly Staple Gun H0580 User Manual

mOdel h0580  
pneumAtIc greASe  
gun  
InStructIOn Sheet  
Head  
Assembly  
eye InJury hAzArd!  
Always wear safety glasses  
during use to prevent  
serious personal injury.  
InJury hAzArd!  
When servicing, always dis-  
connect tool from air to pre-  
vent unexpected operation.  
Cartridge Body  
150 pSI  
Hydraulic Coupler Extension  
mAX AIr preSSure!  
exceeding this pSI may  
result in injury/tool damage.  
Figure 1. Model H0580.  
Specifications  
Quick  
Connector  
Quick  
Connector  
Lubricator  
Regulator  
Air Inlet ....................................................14" NPT  
Average Air Consumption ........................ 4 CFM  
Operating Pressure .................................. 90 PSI  
Capacity................... 14 oz., (400cc bulk grease)  
Weight ........................................3.2 lbs. (Empty)  
Your  
Tool  
Air  
Compressor  
Quick  
Coupler  
Quick  
Coupler  
Air Hose  
Filter  
Inventory (Figure 1)  
A. Grease Gun ............................................... 1  
B. Hydraulic Coupler with Extension .............. 1  
Qty  
Figure 2. Installing a filter/lubricator/regulator to  
improve the lifespan of your tool.  
Operation  
To improve tool lifespan, use a filter/lubricator/  
regulator setup, as shown in Figure 2.  
Otherwise, lubricate multiple times daily with 2–3  
drops of pneumatic tool oil. Place the oil directly  
into the air fitting, as shown in Figure 3.  
Figure 3. Lubricating directly into air fitting.  
If you need help with your new pneumatic tool,  
call our Tech Support at: (570) 546-9663.  
COPyrIGHT © MAy, 2008 By GrIzzLy INduSTrIAL, INC.  
WArnIng: nO pOrtIOn OF thIS mAnuAl mAy Be reprOduced In Any ShApe  
Or FOrm WIthOut the WrItten ApprOvAl OF grIzzly InduStrIAl, Inc.  
#jM10671 PrINTEd IN TAIWAN  
 
Filling from a Bulk grease container  
1. dISCONNECT THE TOOL FrOM THE AIr  
SuPPLy!  
Filling With a Bulk grease pump  
1. dISCONNECT THE TOOL FrOM THE AIr  
SuPPLy!  
2. Pull the follower rod back until it is fully  
extended, the locking tab will automatically  
hold it in place (Figure 4).  
2. Pull the follower rod back until it is fully  
extended, the locking tab will automatically  
hold it in place.  
3. remove the head assembly from the car-  
3. Insert the grease gun grease inlet (part # 11)  
into the proper fitting on the pump operated  
bulk grease container.  
tridge tube.  
4. remove any grease from the cartridge tube  
by pushing the locking tab and carefully  
releasing the follower rod, allowing it to slowly  
move into the cartridge tube.  
4. Operate the bulk grease pump to fill the  
grease gun container.  
5. remove the grease gun from the pump and  
5. Without introducing bubbles, pack grease  
into the head cavity and plunger assembly  
until they are full (Figure 5).  
release the locking tab.  
6. Push the follower rod in as far as possible.  
Bleeding Air pockets  
Head Cavity  
If at any time you experience problems with the  
grease gun dispensing grease, especially after  
refilling, air is likely trapped in the head assem-  
bly.  
Plunger Assembly  
to bleed air pockets from the grease gun:  
1. dISCONNECT THE TOOL FrOM THE AIr  
SuPPLy!  
Bleeder Valve  
2. Pull back on the follower rod until it is fully  
extended (Figure 4).  
Figure 5. Grease locations and bleeder valve.  
3. release the follower rod by pushing on the  
6. Insert the open end of the cartridge tube into  
the barrel or drum of the bulk grease to be  
added.  
locking tab.  
4. Push the follower rod all the way forward  
while holding down the bleeder valve shown  
in Figure 5, until the air is expelled from the  
gun.  
7. Slowly pull the follower handle back while  
pushing the cartridge tube deeper into the  
grease. This method will help prevent draw-  
ing in air bubbles.  
5. reconnect the grease gun to the air supply,  
and pull the trigger several times to release  
any air in the head assembly and verify the  
grease gun works correctly.  
8. When the follower rod is fully extended, allow  
the locking tab to hold it in place (Figure 4).  
9. Securely fasten the head assembly to the  
cartridge tube and release the follower rod by  
pushing on the locking tab.  
note: If the grease gun does not dispense  
grease correctly, repeat this procedure as  
many times as necessary.  
10. Push the follower rod in as far as possible.  
-3-  
H0580 Pneumatic Grease Gun  
 
h0580 parts Breakdown and list  
*
)
.
-
&-  
,
&,  
("&  
("'  
&%  
&&  
(
&.  
&
&'  
&(  
&)  
+
'
&*  
&+  
'%  
'&  
&-"&  
REF PART #  
DESCRIPTION  
REF PART #  
DESCRIPTION  
1
PH0580001  
PH0580002  
PH0580003  
GREASE GUN BODY  
1/4" NPT AIR INLET  
SWITCH  
11  
12  
13  
14  
15  
16  
17  
18  
PH0580011  
PH0580012  
PH0580013  
PH0580014  
PH0580015  
PH0580016  
PH0580017  
PH0580018  
GREASE INLET  
GASKET  
2
3
PLUNGER NUT  
PLUNGER WASHER  
PLUNGER  
3-1  
3-2  
4
PH0580003-1 TRIGGER AND PIN  
PRP37M  
ROLL PIN 3 X 14  
PH0580004  
PH0580005  
PH0580006  
PH0580007  
PH0580008  
PH0580009  
PH0580010  
SPECIAL BODY SCREW  
AIR PLUNGER  
BACKLASH GASKET  
LONG SPRING KIT  
CARTRIDGE TUBE  
5
6
SHORT SPRING  
HEAD  
7
18-1 PH0580018-1 BOTTOM CAP  
8
ADAPTER  
19  
20  
21  
PH0580019  
PH0580020  
PH0580021  
FOLLOWER ROD  
ROD HANDLE  
LOCKING TAB  
9
HYDRAULIC COUPLER EXTENSION  
BLEEDER VALVE  
10  
 

Grizzly Work Light H6440 User Manual
Groupe SEB USA T FAL Iron 028043 User Manual
Hamilton Beach Blender 58148 User Manual
Harbor Freight Tools Grinder 95578 User Manual
Healthrider Treadmill HRTL10982 User Manual
Hotpoint Cooktop GW74 User Manual
HP Hewlett Packard Printer Sentry User Manual
Husqvarna Pole Saw FS 413 User Manual
iHome Battery Charger IB969 User Manual
i Tech Dynamic Headphones iCube User Manual