HP Hewlett Packard Water Pump 0306 User Manual

Operating Instructions & Parts Manual  
FW0154  
0907  
Supersedes  
0306  
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product  
described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in per-  
sonal injury and/or property damage! Retain instructions for future reference.  
Pressure Booster Pumps  
Description  
Unpacking  
Pressure booster pumps increase water pressure from city mains or private water sys-  
tems. Applications include providing high water pressure for washing buildings, dairy  
walls or floors, hog parlors, poultry houses, rinsing or spray cooling equipment, lawn  
sprinkling and insecticide spraying. Stainless steel models can handle salt-water and  
contaminated water in reverse osmosis filter and other aggressive water applications.  
When unpacking the unit, inspect care-  
fully for any damage that may have  
occurred during transit.  
NOTE: Use pump with clear water  
only.  
Single-phase models are equipped with a capacitor start, thermal protected motor.  
Three-phase models require separate overload protection.  
H
Inlet I  
Discharge J  
G
D
A
B
C
E
F
Figure 1  
IL0391  
60 Hz Motor Driven Pump Dimensions (See Figure 1) •  
Chart A  
Stainless  
Powder-Coated Cast Iron  
Fitted  
Dimensions In Inches  
Lbs. Ship  
Steel Fitted Cast Iron Fitted  
Wt.  
A
B
C
D
E
F
G
H
I
J
PB0508S031  
PB0512S051  
PB0516S071  
PB0712S071  
PB1014S101  
PB1016S151  
PB1914S201  
PB2711S201  
PB3506S201  
PB2714S301  
PB3508S301  
-
PB0508C031  
PB0512C051  
PB0516C071  
PB0712C071  
PB1014C101  
PB1016C151  
PB1914C201  
PB2711C201  
PB3506C201  
PB2714C301  
PB3508C301  
-
PB0508A031† 3-1/4 3-3/4 10-3/16 3-7/8 6-1/2 19-15/16 7-3/8 1-7/16 3/4 3/4  
35  
38  
43  
42  
48  
51  
51  
52  
51  
54  
53  
57  
57  
58  
58  
PB0512A051† 3-1/4 3-3/4 13-3/8  
PB0516A071 3-1/4 3-3/4 16-1/2  
PB0712A071 3-1/4 3-3/4 13-3/8  
3-7/8 6-1/2 23-3/8  
3-7/8 6-1/2 27  
3-7/8 6-1/2 23-7/8  
7-3/8 1-7/16 3/4 3/4  
7-3/8 1-7/16 3/4 3/4  
7-3/8 1-7/16 3/4 3/4  
7-3/8 1-7/16 3/4 3/4  
PB1014A101 3-1/4 3-3/4 16-5/16 3-7/8 6-1/2 27-1/4  
PB1016A151 3-1/4 3-3/4 17-5/8  
PB1914A201 3-1/4 3-3/4 18-1/8  
PB2711A201 3-1/4 3-3/4 15-3/8  
3-7/8 6-1/2 29-3/16 7-3/8 1-7/16 3/4 3/4  
3-7/8 6-1/2 29-11/16 7-3/8 1-7/16 3/4 3/4  
3-7/8 6-1/2 27-1/2  
7-3/8 1-7/16  
7-3/8 1-7/16  
1
1
1
1
2
2
2
2
1
1
1
1
2
2
2
2
PB3506A201 3-1/4 3-3/4 13-15/16 3-7/8 6-1/2 25-7/8  
PB2714A301 3-1/4 3-3/4 18-1/2  
PB3508A301 3-1/4 3-3/4 17-1/8  
PB5504A201 3-1/4 3-3/4 13-3/4  
PB5506A301 3-1/4 3-3/4 18-1/16 3-7/8 6-1/2 30-3/16 7-3/8 2-1/8  
PB8504A201 3-1/4 3-3/4 16-1/2  
3-7/8 6-1/2 30-9/16 7-3/8 1-7/16  
3-7/8 6-1/2 29-3/16 7-3/8 1-7/16  
3-7/8 6-1/2 25-15/16 7-3/8 2-1/8  
-
-
-
-
-
-
3-7/8 6-1/2 28-5/8  
7-3/8 2-1/8  
7-3/8 2-1/8  
PB8505A301 3-1/4 3-3/4 19-5/16 3-7/8 6-1/2 31-1/2  
50 Hz Motor Driven Pump Dimensions (See Figure 1) •58  
PB0508Y031  
PB0514Y051  
PB0714Y071  
PB1020Y101  
PB1023Y101  
PB2717Y201  
-
-
PB0508X031 3-1/4 3-3/4 10-3/16 3-7/8 6-1/2 20-3/16 7-3/8 1-7/16 3/4 3/4  
PB0514X051 3-1/4 3-3/4 14-7/16 3-7/8 6-1/2 25-7/16 7-3/8 1-7/16 3/4 3/4  
PB0714X071 3-1/4 3-3/4 14-15/16 3-7/8 6-1/2 25-15/16 7-3/8 1-7/16 3/4 3/4  
PB1020X101 3-1/4 3-3/4 21-11/16 3-7/8 6-1/2 33-5/16 7-3/8 1-7/16 3/4 3/4  
34  
41  
47  
53  
55  
56  
52  
54  
56  
59  
-
-
-
PB1023Z101  
PB1023X101 3-1/4 3-3/4 24-3/8  
3-1/4 3-3/4 21-5/16 3-7/8 6-1/2 33-7/16 7-3/8 1-7/16  
PB3508X151 3-1/4 3-3/4 16-13/16 3-7/8 6-1/2 29-11/16 7-3/8 1-7/16  
3-7/8 6-1/2 36  
7-3/8 1-7/16 3/4 3/4  
-
-
-
1
1
1
1
PB1021Y101  
PB1920Y151  
-
-
-
-
-
-
3-1/4 3-3/4 22-1/2  
3-1/4 3-3/4 24-1/16 3-7/8 6-1/2 34-3/8  
3-1/4 3-3/4 26-1/8 3-7/8 6-1/2 37-3/16 7-3/8 1-7/16 3/4 3/4  
3-7/8 6-1/2 34-3/16 7-3/8 1-7/16 3/4 3/4  
7-3/8 1-7/16 3/4 3/4  
PB1922Z201  
(*) NOTE: Figure 1, holes in mounting base are open slotted 3/8” wide x 1/2” long; dimension A & B are centerline from these  
open slotted holes. These holes are suitable for 1/4 to 3/8” bolts.  
Dimensions also apply to three phase models.  
(†) Equipped with carrying handle. 132079 handle available as an option on other models. Add 1-3/8” to “G” if handle is included.  
1
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
132934  
 
Three Phase Motor Data  
Chart D  
Three Phase† 60/50 Hz 3450/2850 RPM Capacitor Start  
Factory  
Connected  
Motor  
Service Factor Motor  
Amps  
Locked Rotor Motor  
Amps  
Motor  
Voltage  
HP  
Code Letter  
230V  
460V  
230V  
460V  
Voltage  
3/4  
1
1-1/2  
2
208-230/460  
208-230/460  
208-230/460  
208-230/460  
208-230/460  
230V  
230V  
230V  
230V  
230V  
3.5  
4.5  
5.7  
7.4  
9.8  
1.75  
2.25  
2.85  
3.70  
4.90  
19.0  
26.9  
33.5  
44.0  
48.0  
9.5  
K
K
K
K
D
13.5  
16.8  
22.0  
24.0  
3✝✝  
✝✝3 HP, 3 Phase motor operable on 60Hz only.  
Material Construction  
Chart E  
Component  
Standard Models*  
Stainless Steel Models  
Motor  
Rear access - Nema 56J face  
Rear access - Nema 56J face  
Bearings  
Ball-ball, permanently lubricated  
Ball-ball, permanently lubricated  
Impellers  
Noryl with 304 stainless steel bearing insert  
Noryl with 304 stainless steel bearing insert  
Diffuser  
Noryl  
Noryl  
Diffuser plates  
Pump shaft  
Delrin  
Delrin  
416 Stainless steel  
316 Stainless steel  
304 Stainless steel  
Cast iron  
304 Stainless steel  
316 Stainless steel  
304 Stainless steel  
304 Stainless steel  
Viton  
Pump shaft coupling  
Pump shell  
Discharge & inlet casting  
O-Rings  
Buna-N  
Seal composition  
Carbon-silicon carbide, stainless steel spring  
and Buna-N  
Carbon-silicon carbide, stainless steel spring  
and Viton  
*Models with powder coated inlet & discharge also available.  
Minimum Wire Size Chart (Gauge)  
Chart F  
Distance In Feet From Motor To Service Panel  
Motor  
HP  
Breaker Size  
(Amps)  
Volts  
Phase  
0-50  
50-100  
100-150  
Wire Size  
14/14  
12/14  
10/14  
10/12  
6/12  
150-200  
200-300  
1/3  
1/2  
3/4  
1
115/230  
115/230  
115/230  
115/230  
115/230  
115/230  
230  
1
1
1
1
1
1
1
3
3
3
3
3
14/14  
12/14  
12/14  
10/14  
10/12  
10/12  
10  
14/14  
12/14  
12/14  
10/14  
8/12  
12/14  
12/14  
10/12  
8/12  
12/14  
10/14  
8/12  
15/15  
20/15  
20/15  
30/15  
30/20  
30/20  
30  
6/10  
11/2  
2
*/10  
*/10  
8/12  
6/12  
*/10  
*/10  
3
10  
10  
10  
8
3/4  
1
230/460  
230/460  
230/460  
230/460  
230/460  
14/14  
14/14  
14/14  
14/14  
14/14  
14/14  
14/14  
14/14  
14/14  
14/14  
14/14  
14/14  
14/14  
14/14  
14/14  
14/14  
14/14  
12/14  
12/14  
12/14  
14/14  
12/14  
12/14  
10/12  
10/12  
15/15  
15/15  
15/15  
15/15  
15/15  
11/2  
2
3
(*) Not economical to run in 115V, use 230V.  
3
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
 
9. Do not insert finger or any object into pump or motor  
openings.  
10. Secure the discharge line before starting the pump. An  
unsecured discharge line will whip, possibly causing per-  
sonal injury and/or property damage or puncture.  
General Safety Information  
Carefully read and follow all safety instructions in  
this manual and on pump. Keep safety labels in good  
condition. Replace missing or damaged safety labels.  
Do not touch an operating motor or  
engine. They are designed to operate at high temperatures.  
This is a SAFETY ALERT SYMBOL. When you see this  
symbol on the pump or in the manual, look for one of the  
following signal words and be alert to the potential for per-  
sonal injury or property damage.  
!
This product contains chemicals known to  
the State of California to cause cancer and birth defects or  
other reproductive harm.  
Warns of hazards that WILL cause serious  
personal injury, death or major property damage if ignored.  
!
Risk of Electric Shock. This pump has not  
been investigated for use in swimming pool areas.  
NOTE: Pumps with the “CSA-CUS” mark are tested to UL stan-  
dard UL778 and certified to CSA standard C22.2 No. 108.  
!
Warns of hazards that CAN cause serious  
personal injury or death, if ignored.  
Warns of hazards that MAY cause minor  
personal injury, product or property damage if ignored.  
Pre-Installation  
IMPORTANT: Indicates factors concerned with operation,  
installation, assembly or maintenance which could result in  
damage to the machine or equipment if ignored.  
NOTE: Indicates special instructions which are important but  
are not related to hazards.  
HANDLING  
1. Use handle supplied to lift pump.  
2. Avoid impact on pump or motor. In particular, avoid  
impact on discharge end of pump or rear motor access  
cover.  
!
LOCATION  
Wire motor for correct voltage. See  
“Electrical” section and Motor Data Charts  
C&D of this manual, and motor nameplate.  
!
In any installation where property dam-  
age and/or personal injury might result from an inoperative  
or leaking pump due to power outages, discharge line block-  
age, or any other reason, a backup system(s) should be used.  
1. Locate pump as close to the fluid source as possible, keep-  
ing the inlet pipe short as possible.  
2. Place unit where the pump and piping are protected from  
the weather and extremes of heat, humidity and below  
freezing temperatures.  
3. Mount unit in a dry location that is easily accessible for  
inspection and maintenance. If a dry location is not avail-  
able, mount it on a foundation well above the wet floor.  
4. Allow ample clearance around unit for free air circulation.  
SUCTION LIMITATIONS  
Ground motor before connecting to  
power supply.  
Meet United States National Electrical  
Code and local codes for all wiring.  
Hazardous volt-  
age. Can shock,  
burn or cause  
Do not handle a pump or pump motor  
death. Ground  
with wet hands or when standing on a wet  
pump before con-  
necting to power  
supply.  
or damp surface or in water.  
Follow wiring instructions in this manual when connect-  
ing to power lines.  
1. Units are non self-priming.  
2. Pressure booster pumps are not recommended for suction  
lift applications.  
!
Always disconnect power source before  
performing any work on or near the motor or its connected  
load.  
PIPING  
1. Use galvanized piping, rigid plastic or other suitable pipe  
that will not collapse under suction or rupture due to pres-  
sure.  
Do not use to pump flammable or explosive fluids  
such as gasoline, fuel oil, kerosene, etc. Do not use in flam-  
mable and/or explosive atmospheres.  
If hose is used, make sure it is the rein-  
forced industrial type that is rated higher than the shutoff  
pressure of the system. Ordinary garden hose will collapse  
and starve the pump of water.  
2. The diameter of the inlet and discharge pipe should be  
no smaller than the corresponding ports of the pump (See  
Figure 1). Smaller pipe will reduce the capacity of the  
pump. Increase pipe size on long runs.  
3. Avoid air pockets in inlet piping or air will accumulate at  
high points, making priming difficult.  
Hazardous pressure! Install pressure relief valve in  
discharge pipe. Release all pressure on system before work-  
ing on any component.  
1. Make workshop child proof - use padlocks, master  
switches; remove starter keys.  
2. Wear safety glasses when working with pumps.  
3. Wear a face shield and proper apparel when pumping  
hazardous chemicals.  
4. Use pipe compound on all joints and connections. Use  
Teflon tape or plastic joint stik, on plastic pipe. Draw all  
pipe up tightly.  
4. Keep work area clean, uncluttered and properly lighted;  
replace all unused tools and equipment.  
IMPORTANT: The entire system must be air and water tight  
for efficient/proper operation.  
5. Provide guarding around moving parts.  
6. Keep visitors at a safe distance from the work area.  
7. Periodically inspect pump and system components.  
8. Protect electrical cord. Replace or repair damaged or  
worn cords immediately.  
4
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
 
No Air Leaks In  
Inlet Pipe  
Pipe Joint Compound  
Will Damage Plastic  
Installation  
PUMP INSTALLATION  
Sags Allow Air Pockets  
No Sags  
IMPORTANT: Pump is built to handle  
clear water only; it is not designed to  
handle water containing sand, silt or  
other abrasives.  
If Air Flows  
Water  
Won’t  
1.Refer to Figures 6, 7, and 8 for typi-  
cal installations.  
IL0419  
Support pump and  
piping when assembling and when  
installed. Failure to do so may cause  
piping to break, pump to fail, motor  
bearing failures, etc.  
IL0418  
If Air Pockets Form,  
Water Won’t Flow  
IL0420  
Use Teflon Tape  
Figure 3 - Inlet Pipe Must Not Leak  
2. If the pump is used as part of a per-  
manent installation, bolt to a rigid  
foundation.  
Figure 2 - No Air Pockets in Inlet Pipe  
Mount pump in correct position or pump failure will result.  
!
Use only compo-  
nents that are rated for maximum pres-  
sure pump can produce when used in  
boosting system or any other system.  
Do not exceed the total maximum  
pressure boost as listed per model in  
Performance Charts B.  
Correct  
Incorrect  
PRESSURE BOOST SYSTEMS  
1. On pressure boost systems, locate  
the pump so that there will always  
be a positive supply of water to the  
pump (See Figures 6, 7 and 8).  
2. For service convenience, install a  
gate valve and union in the inlet  
and discharge line.  
IL0315  
Figure 4A  
Figure 4B  
Do not use a globe  
valve or other restricting type of valve  
that will seriously restrict the pumps  
discharge capacity.  
SAND AND SEDIMENT TRAP FILTER  
3. Install a check valve as shown in  
Figure 6. Be sure check valve flow  
arrows point in the direction of  
water flow.  
4. Whenever dirt, sand or debris is  
present in the supply water, install a  
strainer or filter on the inlet side of  
the pump (See Figure 7).  
Standard Pressure  
Tank - 42 Gallon Or  
Larger  
Outlet  
Inlet  
NOTE: For heavy amounts of sedi-  
ment, install a trap filter on the inlet  
side of the pump (See Figure 5).  
NOTE: Pressure gauges installed  
before and after the filter will show  
pressure differential indicating the  
need for filter replacement or clean-  
ing.  
Clean Out  
Sand Settles To The Bottom  
IL0421  
Figure 5  
IMPORTANT: Clean all filters and strainers on a regular schedule.  
5
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
 
Pump used to boost incoming city pressure (automatic operation).  
Installation (Continued)  
5.A pressure gauge installed in the  
inlet pipe close to the inlet port, (See  
Figure 6) will show if enough water  
is being supplied to the pump. See  
Operation Section - Priming, Pressure  
Boost Installations.  
6. On installations that are using noz-  
zles for mist spraying, install a filter  
in the discharge plumbing to prevent  
the nozzles from becoming plugged.  
Multiple filters should be plumbed in  
parallel.  
Street Supply  
Gate/Ball  
Valve  
(Normally  
open)  
Main Power Box  
Check Valve  
Union  
Gate/Ball  
Valve  
(Normally  
open)  
To size tank  
properly - Match  
drawdown of  
tank to capacity  
of pump  
Fuse  
Box or  
Switch  
Check  
Valve  
Pressure  
Gauge  
Union  
Union  
Service Tee  
!
Install a pressure  
Inlet  
Outlet  
Pressure Switch  
relief valve on any installation where  
pump pressure can exceed the pressure  
tanks maximum working pressure or  
on systems where the discharge line  
can be shut off or obstructed. Extreme  
over pressure can result in personal  
injury or property damage.  
Pressure  
Switch  
Pressure  
Gauge  
IL0422  
This unit is not  
waterproof and is not intended to  
be used in showers, saunas or other  
potentially wet locations. The motor  
is designed to be used in a clean dry  
location with access to an adequate  
supply of cooling air. Ambient tem-  
perature around the motor should  
not exceed 104ºF (40ºC). For outdoor  
installations, motor must be protected  
by a cover that does not block airflow  
to and around the motor. This unit is  
not weatherproof nor is it able to be  
submersed in water or any other liq-  
uid.  
Pressure  
Relief  
Valve  
Drain  
Figure 6  
IMPORTANT: A contained air pressure tank and pressure switch is required to  
keep the pump from rapid cycling and prevent the motor from over heating.  
Install the tank and switch on the house side of system.  
Pump used to boost water pressure in mist spray applications (automatic opera-  
tion).  
Fuse Box  
or Switch  
Pressure Gauge  
Thermostat  
To avoid dangerous or fatal elec-  
trical shock, turn off power to motor  
before working on electrical connec-  
tions.  
Gate/Ball Valve  
From Water Source  
Line Filter  
Pressure  
Relief  
Valve  
Supply voltage must be within  
10% of nameplate voltage. Incorrect  
voltage can cause fire or seriously  
damage motor and voids warranty. If  
in doubt, consult a licensed electrician.  
Gate/Ball Valve  
(Normally open)  
Solenoid  
Valve  
Use wire size specified in wiring  
Chart F. If possible, connect pump  
to a separate branch circuit with no  
other appliances on it. If motor wiring  
diagram differs from diagram shown  
below, follow diagram on motor.  
To Nozzles  
To Drain  
IL0423  
Figure 7  
NOTE: Install solenoid valve on discharge side of pump.  
IMPORTANT: Clean all filters and strainers on a regular schedule.  
6
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
 
Pump used to boost incoming pressure from a wall hydrant (manual operation).  
Installation (Continued)  
Hose Adapter  
Wall Hydrant  
!
Ground motor  
Pressure Gauge  
before connecting to  
electrical power sup-  
ply.  
Pressure  
Relief Valve  
Service Tee  
Hose Adapter  
Failure to ground  
motor can cause  
Inlet  
High Pressure Reinforced Hose  
severe or fatal electri-  
cal shock hazard.  
Hazardous  
voltage. Can  
Outlet  
shock, burn or  
cause death.  
Ground pump  
before connecting  
to power supply.  
Do not ground to  
a gas supply line.  
Spray  
Nozzle  
IL0424  
High Pressure Reinforced Hose  
Figure 8  
Proper rotation of  
pump impeller is critical on three phase  
motors. See Motor Rotation under  
Operation section and Figure 12.  
230 Volts  
Single Phase  
115 Volts  
Single Phase  
WIRING  
Line  
Line  
1. Install, ground, wire and maintain  
this pump in accordance with your  
local electrical code and all other  
codes and ordinances that apply.  
Consult your local building inspector  
for local code information.  
2. Ground the pump permanently using  
a wire of size and type specified  
by local or United States National  
Electrical Code. Do not ground to  
a gas supply line.  
3.Connect ground wire first. Connect  
to ground first, then to green ground-  
ing terminal provided on the motor  
frame, identified as GRD. Ground con-  
nection MUST be made to this termi-  
nal. Do not connect motor to electrical  
power supply until unit is permanently  
grounded; otherwise serious or fatal  
electrical shock hazard may be caused.  
4. Connect the other end of the ground  
wire to a properly grounded service  
panel or to a control panel ground  
bar if it is connected to the power  
supply ground.  
L1  
L1  
L2  
L2  
A
B
A
B
Y
E
L
L
O
W
W
H
I
T
E
G
R
A
Y
R
E
D
T
A
N
Y
E
L
L
O
W
W
H
I
T
E
G
R
A
Y
R
E
D
T
A
N
IL0180  
NOTE: Dual voltage motors, change the red and  
gray wire to the voltage required.  
Figure 9 - Wiring Diagram for Single Phase 1/3 - 2 HP  
Motors  
230 Volts  
Single Phase  
Line  
L1  
L2  
A
B
IMPORTANT: Check local and/or  
United States National Electric Codes  
for proper grounding information.  
Y
E
L
G
R
A
Y
L
O
W
Make certain that  
the power supply conforms to the elec-  
trical specifications of the motor sup-  
IL0181  
NOTE: Single voltage (230V) motor, and can not be connected to 115V.  
plied. See Motor Data Charts.  
Figure 10 - Wiring Diagram for Single Phase 3 HP Motors  
7
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
 
Installation (Continued)  
5.Specific Wiring Procedure (Refer to Figures 9, 10, & 11  
and Minimum Wire Size Chart).  
a. Select the voltage you are to use, either 115V or 230V  
single phase, 230V or 460V three phase.  
Low Voltage 230V  
High Voltage 460V  
5
4
5
6
4
6
b. The 1/3, 1/2 and 3/4 HP single phase pumps are factory  
connected for 115V at the motor. The 1, 11/2, 2 and 3  
HP pumps are factory connected for 230V at the motor.  
Three phase models are factory connected for 230V at  
the motor.  
c. If the motor wiring must be changed to conform to your  
specific voltage requirements then the motor, pressure  
switch or other controls should be rewired to conform  
to one of the wiring diagrams (either 115V or 230V,  
single phase; 230V or 460V, three phase). Single phase 3  
HP motors are 230V only and cannot be wired for 115V  
service.  
8
7
9
8
7
9
1
1
3
2
2
3
L2  
L1  
L2  
L1  
L3  
L3  
IL0182  
1 - Tan  
4 - Yellow  
7 - Purple  
8 - Gray  
2 - Red  
5 - Black  
6 - Blue  
3 - Orange  
9 - White  
d. The motor wiring diagrams are Figures 9, 10, & 11 and  
also are located on the motor label of the pump.  
CONNECTION FOR 3 PHASE, 9 LEADS. IF YOUR 3 PHASE  
LEADS ARE COLOR CODED, MATCH NUMBER ABOVE TO THE  
CORRESPONDING COLOR.  
6. Remove the rear access cover of the motor.  
7. Make the wiring change and replace the rear access cover.  
NOTE: To reverse rotation, interchange any two incoming lines  
!
Replace rear access cover before starting  
(Power) leads.  
or operating pump. Failure to do so can result in personal  
injury.  
Figure 11 - Wiring Diagram for Three Phase Motors  
IMPORTANT: Do not use an extension cord or splice wires.  
Joints should be made in an approved junction box. If the  
above information or the following wiring diagrams are con-  
fusing, consult a licensed electrician.  
8. All units are not supplied with pressure switches, float  
devices, on/off switches, or the like (control devices).  
Controls should be wired in at this time, utilizing whatever  
instructions come with the controls. All units supplied  
with cords, will run whenever cord is plugged into power  
and will turn off whenever cord is disconnected from  
power.  
Operation  
Unit must be full of fluid before operat-  
ing. Do not run dry, or against a closed discharge. Do not  
pump dirty water or abrasive liquids. To do so will cause  
pump failure and will void the warranty.  
VALVES  
The inlet valve should be in the full open position and the  
discharge valve should be partially open, permitting some  
back pressure to be exerted against the pump when starting  
up. Open valve after start up is completed.  
PRIMING  
MOTOR PROTECTION  
All single phase motors have built in thermal protection for  
all voltages. The overload protects the motor against burn-  
out from overload of low voltage, high voltage and other  
causes. The device is automatic and resets itself once the  
temperature has dropped to a safe point. Frequent tripping  
of the device indicates trouble in the motor or power lines  
and immediate attention is needed.  
NOTE: Before starting the pump it is absolutely necessary  
that both the pump and the inlet pipe be completely  
filled with water.  
PRESSURE BOOST INSTALLATIONS  
Priming is automatic when pump is connected to a pressure  
source such as a hydrant or city main (See Figures 6, 7 & 8).  
1. Open valves or nozzle on inlet and discharge side of pump.  
!
Never examine, make wiring changes or  
touch the motor before disconnecting the main electrical  
supply switch. The thermal device may have opened the  
electrical circuit.  
2. To relieve trapped air, allow water supply to run a mini-  
mum of 30 seconds before starting the pump.  
IMPORTANT: An adequate flow of water going into the  
pump is required so that the pumps impellers and shaft seal  
do not run dry and fail.  
3. If you installed a pressure gauge at the pump inlet, a read-  
ing of 2 psi minimum should show whenever the pump is  
in operation (See Figures 6, 7 & 8).  
Three phase motors do not have a built in thermal protec-  
tion. It is recommended that a properly sized magnetic or  
manual starter (both with properly sized heaters) be used  
with all three phase motors. Install starters following instruc-  
tions of the starter manufacturer. See Motor Rotation under  
Operation Section for changing rotation on three phase  
motors.  
All motors (single and three phase) should be equipped  
with a correctly fused disconnect switch to provide protec-  
tion. Consult local or United States National Electric Codes  
for proper fuse protection based on motor data chart (See  
Charts C, D and Wire chart F).  
This reading insures that there is an ample supply of water  
into the pump inlet housing.  
8
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
 
bling, reapply thread sealer.  
PUMP DISASSEMBLY  
To disassemble the pump, refer to the exploded parts view,  
Figures 17 & 18 Tools Required  
• Block of wood (2” x 4” x 12”)  
Piece of 3/4” pipe (12” to 24” long)  
• Pipe wrench  
• Strap wrench  
• 1/4” Dowel rod (about 24” long)  
• 9/16” Open end wrench  
• 3/8” Open end wrench  
1. To stabilize pump during disassembly, place block of wood  
underneath pump barrel.  
2. Thread pipe into pump inlet port. This acts as a handle.  
3. Using the pipe wrench, remove the discharge head, turn-  
ing CCW (counter clockwise).  
4. With the strap wrench, loosen the barrel, turning CCW  
(counter clockwise). DO NOT use pipe wrench on pump  
barrel.  
Operation (Continued)  
MOTOR/PUMP ROTATION  
1. Single phase models are one (1) rotation only (counter-  
clockwise when facing the pump end) and cannot be  
reversed.  
2. Proper rotation of pump impeller is critical for three phase  
pumps. Pump motor should turn counterclockwise (CCW)  
when facing pump end. Momentarily “bump” (apply  
power for less than a second) the motor to check for  
proper rotation. To change rotation on three phase units,  
interchange any two (2) incoming line (power) leads.  
Do not go over recommended maximum  
operating pressure (see Specifications), while maintaining  
minimum flow of 1.5 GPM thru the pump. Do not restrict  
the inlet line to the pump.  
If driver (electric motor) is overloaded, a valve can be  
installed in the discharge line to increase the back pressure  
and reduce driver loading.  
5. Holding the impeller stack in place, position pump in  
upright position, standing unit on the motor end cover.  
6. Use the 1/4” dowel rod to hold the stages down and in  
place on the pump shaft. Remove pump barrel.  
7. Slide the stages off the pump shaft onto the 1/4” dowel  
rod. Leave stages on rod and carefully set aside.  
NOTE: There may be some small .010” shim washers located  
next to the pump shaft coupling. Keep these shims for re-  
assembly.  
START - UP PROCEDURE  
Once the preceding instructions have been completed, the  
pump can be started.  
1. During the first few hours of operation, inspect the pump,  
piping and any auxiliary equipment used in connection  
with the unit.  
2. Check for leaks, excessive vibration or unusual noises.  
8. Through the side opening of the mounting frame, hold  
the motor shaft with 9/16” wrench. Remove the shaft and  
coupling from the motor using the 3/8” wrench on the hex  
shaped pump shaft.  
NOTE: If the hex shaft comes free, leaving the coupling  
attached to the motor, use vise grips to free the coupling.  
MECHANICAL SEAL REPLACEMENT  
1. Follow instructions under “Pump Disassembly”.  
2. Remove the mechanical seal assembly.  
a. The rotary portion of the seal assembly (carbon ring,  
Buna-N gasket and spring will slide easily off the end of  
shaft).  
IL0539  
Figure 12 - Correct Motor/Pump Rotation (all units)  
NOTE: See rotation arrow on inlet casting.  
b. Using two (2) screwdrivers, pry the ceramic seal and rub-  
ber gasket from the recess of the mounting ring (See  
Figure 14).  
Maintenance  
Disconnect power supply and depressur-  
ize system before servicing pump or removing any compo-  
nent.  
The precision lapped faces of the mechan-  
ical seal are easily damaged. Handle the replacement seal  
carefully. Short seal life will result if seal faces (ceramic &  
carbon) are nicked, scratched or dirty.  
3. Clean the seal cavity of the mounting ring and the motor  
thoroughly.  
ROUTINE  
Pump should be checked routinely for proper operation.  
Replace or clean all filters and line strainers on a regular  
basis.  
4. Wet outer edge of rubber cup on ceramic seat with liquid  
soap solution. Use sparingly (one drop only).  
DRAINING  
This pump cannot be completely drained because of internal  
design. Most of the liquid can be drained by tilting the dis-  
charge forward after removing discharge casting; or, the liq-  
uid can be drained through the inlet port. Store in heated  
areas.  
CLEANING  
If used for spraying insecticides, pump should be thoroughly  
flushed with clean water after using.  
LUBRICATION  
The motor has prelubricated bearings. No lubrication is  
required.  
SERVICING THREE-PHASE UNITS  
Loctite (thread sealer) is used on the threads between the  
motor shaft and the pump shaft coupling. When reassem-  
9
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
 
2. Remove cap screws that connect the motor to the  
mounting ring and pull motor away.  
3. Replace motor with standard Nema 56J jet pump motor  
by positioning motor against the mounting frame and  
assembling with four (4) cap screws.  
IMPORTANT: Because damage to the shaft seal can occur in  
disassembly, a new seal will be necessary.  
PUMP REASSEMBLY  
Before reassembling the pump, carefully inspect the com-  
ponent parts of the cartridge (stage) assembly, looking for  
damage, wear or heat distortion. Pay careful attention to  
spacing direction of components, and location of shims.  
Refer to Figure 16 for proper facing and parts arrangement.  
If damage to Stage components is evident, a complete car-  
tridge assembly or individual stage assemblies are available  
for replacement (See Replacement Parts List).  
1. Reassembly should follow the reverse order of the disas-  
sembly procedure with special care given to replacement  
of the rotary seal.  
Maintenance (Continued)  
NOTE: Liquid soap solution - one drop of liquid soap com-  
bined with one teaspoonful of water.  
5. With thumb pressure, press ceramic seal half firmly and  
squarely into seal cavity. Polished face of ceramic seat  
is up. If seal will not seat correctly, remove, placing seal  
face up on bench. Reclean cavity. Seal should now seat  
correctly (See Figure 14).  
6. If seal does not seat correctly after recleaning cavity,  
place a cardboard washer over polished seal face and  
carefully press into place using a piece of standard clean  
3/4” pipe as a press (See Figure 15).  
IMPORTANT: Do not scratch seal face.  
7. Dispose of cardboard washer and recheck seal face to  
be sure it is free of dirt, foreign particles, scratches and  
grease.  
8. Inspect shaft to be sure it is free of nicks and scratches.  
9. Apply liquid soap solution sparingly (one drop is suffi-  
cient) to inside diameter of rubber rotating member.  
10. Slide rotating seal member (carbon face down toward  
ceramic face) and spring over the shaft.  
IMPORTANT: Do not nick or scratch carbon face of seal  
when handling.  
MOTOR REPLACEMENT  
The motor can be replaced with any standard Nema 56J jet  
pump motor (of proper HP for each pump) by referring to  
the following instructions.  
1. Follow steps as outlined under Rotary Seal Replacement  
and Pump Disassembly.  
2. Check top and bottom of o-rings for damage. It is recom-  
mended that new o-rings be used.  
3. Do not use pipe compound of Teflon tape on barrel  
threads. The o-rings will prevent pump from leaking.  
4. After pump is reassembled, tighten the discharge head to  
a torque of 45-50 ft/lbs. If torque wrench is not available,  
tighten firmly but avoid distortion or damage to plastic  
internal parts.  
5. After reassembly, apply power momentarily to unit (15 to  
30 seconds). The pump and motor should rotate freely or  
with a light rubbing.  
3/4” Pipe  
Press Carefully  
Cardboard  
Washer  
Protects Seal  
Face  
Seal  
Seal Cavity  
IL0554  
Figure 13 - Remove Mechanical Seal  
Figure 14 - Press In Seal  
Figure 15 - If Necessary, Press With  
Cardboard And Pipe  
10  
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
 
Troubleshooting Chart  
Symptom  
Possible Cause(s)  
Corrective Action  
Pump won’t  
start or run  
at full speed  
1. Blown fuse or open circuit breaker  
1. Replace fuse or close circuit breaker. See wire size chart for  
proper break/fuse size  
2. Power supply in OFF position  
2. Turn power on  
3. Low voltage  
3. Incorrect voltage at motor (check volt-  
age with motor running)  
a. Voltage must be within 10% of motor rated voltage.  
Check incoming voltage. Contact power company  
b. Make certain that voltage of motor matches voltage of  
power supply. See motor name plate and motor wiring  
diagrams  
c. Check wire size from main switch to pump. See wire  
size chart for correct wire size  
4. Loose, broken or incorrect wiring  
5. Defective motor  
4. Rewire any incorrect circuits. Tighten connections, replace  
defective wires  
5. Replace motor  
6. Pump hydraulic components clogged/  
worn/damaged  
6. Replace worn parts or entire pump. Clean parts if required  
Pump oper-  
ates, but  
delivers little  
or no water  
1. Manual or solenoid valves plumbed  
into system restricting flow  
1.  
a
Check all valves on pump inlet and discharge sides of  
system to be sure they are opened properly to allow  
flow to and from the pump  
b. Bleed trapped air in pump which keeps water from  
reaching the pump. (Normally  
due to closed valve in discharge plumbing)  
2. In-line filter restricting flow  
3. Low line voltage  
2. Check all in-line filters to be sure they are not plugged or  
restricted  
3. See low line voltage corrective action (above)  
4. Inadequate water supply to booster  
pump  
4. Check pressure on inlet side of booster to be sure positive  
pressure is maintained to the booster pump  
5. Undersized piping  
5. Replace undersized piping  
6. Leak on inlet side of system  
6. Make sure connections are tight. Repair leaks as necessary  
7. Clean, repair or replace as needed  
7. Inadequate, defective or plugged foot  
valve and/or strainer  
8. Worn or defective pump parts or  
pump.  
8. Replace worn parts or entire plugged impeller Clean parts if  
9. Suction lift too great  
9. Pump should be operated under  
flooded suction only  
10. Pump not primed  
10. Prime pump - Make certain inlet pipe is drawn up tight and  
pump and pipe are full of water  
11. Incorrect rotation, motor running  
backwards  
11. Reverse motor rotation can occur on three phase units. To  
correct, interchange any two incoming power leads.  
Excessive  
noise while  
pump in  
1. Pump not secured to firm foundation  
2. Piping not supported  
1. Secure properly  
2. Make necessary adjustments  
3. Clean or correct  
3. Restricted inlet line  
4. Cavitation (noise like marbles in pump)  
4. a. Reduce speed on direct drive  
b. Increase inlet pipe size  
c. Too viscous (material being pumped too thick  
5. Replace bearings or motor  
1. Replace shaft (rotary) seal  
5. Worn motor bearings  
Pump leaks  
1. Worn mechanical seal (leaks at shaft)  
2. Worn o-ring seals  
2. Replace o-ring seals, located inside both ends of the stainless  
steel shell  
11  
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
 
Booster Pump Parts Drawing  
1A  
1
9
2
10A  
5
7
1B  
10  
6A  
6E  
6D  
8
6A  
ITEM NO. DESCRIPTION  
1
1A  
1B  
2
3
4
Motor  
†Governor  
†Switch Motor  
Seal, Rotary  
Barrel  
Discharge Head  
Discharge Bearing  
O-ring (2)  
Plate, Diffuser  
Impeller  
5
4A  
4
6B  
4A  
5
6C  
3
6A  
6B  
6C  
6D  
6E  
7
8
9
10  
10A  
Diffuser  
IL0593  
Diffuser Bearing  
Shim as Required  
Shaft and Coupling Assembly  
Mounting Ring  
Hex Head Bolts (4)  
†MotorAccess Cover  
†Screws, Access Cover (2)  
*See note below parts included in cartridge assembly.  
†ODP Motor Only  
Internal Parts Detail  
IL0308  
Figure 16 - Cartridge Assembly Includes Discharge Bearing, Shaft & Coupling Assembly, Diffuser Plate, Impellers, Diffuser  
Bearings, Diffusers and O-rings  
NOTE: Illustration shows only two stages. Pump has multiple stages. Individual parts are not available separately.  
12  
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
 
FORM NO. FW0045  
0907  
SUPERSEDES 0206  
PAGE 4-7A REPAIR PARTS  
PRESSURE BOOSTER PUMP REPAIR PARTS  
(For Pricing Refer To Repair Parts Price List)  
Replacement Motors  
9
10  
IL0565  
POWDER  
COATED  
STAINLESS  
STEEL  
POWDER  
COATED  
STAINLESS  
STEEL  
ITEM REPLACEMENT MOTORS  
QTY  
CAST IRON  
CAST IRON  
SINGLE PHASE 60 HZ  
96J103  
THREE PHASE 60 HZ  
ODP NEMA J 1/3 HP  
ODP NEMA J 1/2 HP  
ODP NEMA J 3/4 HP  
ODP NEMA J 1 HP  
ODP NEMA J 1-1/2 HP  
ODP NEMA J 2 HP  
ODP NEMA J 3 HP  
Motor Cover w/Screws  
Screws, Motor Cover  
96J103  
96J105  
96J107  
96J110  
96J115  
96J120  
96J630  
136132R  
136133  
96S103  
96S105  
96S107  
96S110  
96S115  
96S120  
96S630  
136132R  
136133  
96J105  
96J107  
96J110  
96J115  
96J120  
96J630  
136132R  
136133  
96J305  
96J307  
96J310  
96J315  
96J320  
96J330  
136132R  
136133  
96J305  
96J307  
96J310  
96J315  
96J320  
96J330  
136132R  
136133  
96S305  
96S307  
96S310  
96S315  
96S320  
96S330  
136132R  
136133  
9
1
10  
*
1
2
SINGLE PHASE 50 HZ  
96J003  
THREE PHASE 60/50 HZ  
ODP NEMA J 1/3 HP  
ODP NEMA J 1/2 HP  
ODP NEMA J 3/4 HP  
ODP NEMA J 1 HP  
ODP NEMA J 1-1/2 HP  
ODP NEMA J 2 HP  
Motor Cover w/Screws  
Screws, Motor Cover  
96J003  
96J005  
96J007  
96J010  
96J015  
96J820  
136132R  
136133  
96S003  
96S005  
96S007  
96S010  
96S015  
96S820  
136132R  
136133  
96J005  
96J007  
96J010  
96J015  
96J820  
136132R  
136133  
96J305  
96J307  
96J310  
96J315  
96J320  
96J305  
96J307  
96J310  
96J315  
96J320  
96S305  
96S307  
96S310  
96S315  
96S320  
136132R  
136133  
9
1
10  
*
1
2
136132R  
136133  
136132R  
136133  
SINGLE PHASE 60/50 HZ  
THREE PHASE 60/50 HZ  
021011  
TEFC NEMA J 1/2 HP  
TEFC NEMA J 3/4 HP  
TEFC NEMA J 1 HP  
TEFC NEMA J 1-1/2 HP  
TEFC NEMA J 2 HP  
TEFC NEMA J 3 HP  
020691  
021008  
021009  
020692  
020693  
021010  
020691  
021008  
021009  
020692  
020693  
021010  
021011  
021012  
020688  
020647  
020689  
020690  
021012  
020688  
020647  
020689  
9
1
020690  
* Not Shown  
13  
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
 
FORM NO. FW0046  
0907  
SUPERSEDES 0206  
PAGE 4-8A REPAIR PARTS  
PRESSURE BOOSTER PUMP REPAIR PARTS  
(For Pricing Refer To Repair Parts Price List)  
7
10  
8
3
1
6
9
4
4
2
IL0565  
POWDER  
COATED  
136905  
STAINLESS  
STEEL  
136640  
ITEM  
DESCRIPTION  
QTY  
CAST IRON  
1
2
Discharge Head 3/4” NPT  
Mounting Ring 3/4” NPT  
1
1
132000  
132002  
5 - 7 - 10 - 19 GPM,  
60 HZ & 50 HZ  
136904  
136639  
See  
replacement  
motors.  
1
2
Discharge Head 1” NPT  
Mounting Ring 1” NPT  
1
1
136635  
136634  
137796  
137794  
139166  
139100  
27 - 35 GPM,  
60 HZ & 50 HZ  
1
2
Discharge Head 2” NPT  
Mounting Ring 2” NPT  
1
1
021585  
021584  
-
-
-
-
55 - 85 GPM,  
60 HZ & 50 HZ  
ITEMS 9 & 10  
3
4
*
Seal, Rotary w/Spring  
O-Ring  
1
2
4
131100 †  
131925  
121106  
131100 †  
131925 ■  
121106  
136682 ‡  
136607 ▲  
121106  
ALL SERIES  
60 HZ & 50 HZ  
Hex Head Cap Screws 3/8” x 3/4”  
(†) Buna N - Carbon/Silicon Carbide (‡) Viton - Carbon/Silicon Carbide () Buna N () Viton (*) Not Shown  
(8) 132079 Handle available as an option  
CAST IRON CI  
POWDER COATED PC  
STAINLESS STEEL SS  
DESCRIPTION MATERIAL  
CI & PC  
PB0508AXXX  
PB0508CXXX  
PB0508SXXX  
PB0512AXXX  
PB0512CXXX  
PB0512SXXX  
PB0516AXXX  
PB0516CXXX  
PB0516SXXX  
PB0712AXXX  
PB0712AXXX  
PB0712SXXX  
PB1014AXXX  
PB1014CXXX  
PB1014SXXX  
PB1016AXXX  
PB1016CXXX  
PB1016SXXX  
MATERIAL  
ITEM  
PART NUMBER  
135163  
132939  
136683  
133336  
136636  
132003  
138447  
138450  
138446  
138449  
138448  
134097  
136684  
133336  
136636  
132003  
134998  
136685  
134996  
136637  
134997  
135814  
136686  
135813  
136638  
135815  
5
Cartridge Assembly ‡  
SS  
CI & PC  
SS  
135161  
138938  
135162  
6
7
Shaft & Coupling Assembly  
Barrel/Shell  
CI, PC & SS  
CAST IRON CI  
PB1914AXXX  
PB1914CXXX  
PB1914SXXX  
PB2711AXXX  
PB2711CXXX  
PB2711SXXX  
PB2714AXXX  
PB2714CXXX  
PB2714SXXX  
PB3506AXXX  
PB3506CXXX  
PB3506SXXX  
PB3508AXXX  
PB3508CXXX  
PB3508SXXX  
MATERIAL  
POWDER COATED PC  
STAINLESS STEEL SS  
DESCRIPTION MATERIAL  
CI & PC  
ITEM  
PART NUMBER  
137222  
139162  
137221  
139159  
137223  
135627  
139163  
136624  
139157  
135628  
136629  
138946  
136628  
137535  
136630  
136626  
139164  
136625  
139156  
136627  
136632  
139165  
136631  
139158  
136633  
5
Cartridge Assembly ‡  
SS  
CI & PC  
SS  
CI, PC & SS  
6
7
Shaft & Coupling Assembly  
Barrel/Shell  
MATERIAL  
ITEM  
CAST IRON CI  
DESCRIPTION MATERIAL  
PB5504XX  
PB5506XX  
PB8504XX  
PB8505XX  
PART NUMBER  
5
6
7
Cartridge Assembly ‡  
Shaft & Coupling Assembly CI  
Barrel/Shell  
CI  
022293  
022289  
022291  
022294  
022287  
022292  
022295  
022288  
138151  
022296  
022287  
022290  
CI, PC & SS  
CAST IRON CI  
PB0508XXXX  
PB0508ZXXX  
PB0508YXXX  
PB0514XXXX  
PB0514ZXXX  
PB0514YXXX  
PB0714XXXX  
PB0714ZXXX  
PB0714YXXX  
PB1020XXXX  
PB1020ZXXX  
PB1020YXXX  
PB1022XXXX  
PB1022ZXXX  
PB1022YXXX  
PB1023XXXX  
PB1023ZXXX  
PB1023YXXX  
MATERIAL  
POWDER COATED PC  
STAINLESS STEEL SS  
DESCRIPTION MATERIAL  
CI & PC  
ITEM  
PART NUMBER  
135163  
138150  
138682  
138149  
138444  
138151  
021032  
021033  
138149  
138444  
138151  
135907  
138683  
135906  
138154  
135098  
135911  
138684  
135910  
137103  
135912  
5
Cartridge Assembly ‡  
SS  
020280  
020278  
020278  
020279  
CI & PC  
SS  
CI, PC & SS  
135161  
138938  
135162  
6
7
Shaft & Coupling Assembly  
Barrel  
CAST IRON CI  
PB1920XXXX  
PB1920ZXXX  
PB1920YXXX  
PB2717XXXX  
PB2717ZXXX  
PB2717YXXX  
PB3508XXXX PB3514XXXXT  
MATERIAL  
POWDER COATED PC  
STAINLESS STEEL SS  
DESCRIPTION MATERIAL  
CI & PC  
PB3508ZXXX PB3514ZXXXT PB1922ZXXX  
PB3508YXXX PB3514YXXXT  
PART NUMBER  
ITEM  
020982  
020095  
020971  
020093  
020094  
020980  
138949  
020916  
138948  
138947  
136632  
139165  
136631  
139158  
136633  
021017  
021026  
021015  
021020  
021016  
139435  
*
139434  
021425  
139436  
5
Cartridge Assembly ‡  
SS  
CI & PC  
SS  
CI, PC & SS  
6
7
Shaft & Coupling Assembly  
Barrel  
(‡) Cartridge assembly includes: impellers, diffusers and shaft & coupling assembly. Components not available individually. Sold as assembly only.  
14  
FLINT & WALLING, INC. • 95 North Oak St. • Kendallville, IN 46755 • www.flintandwalling.com  
 

GSI Outdoors Humidifier PNEG 1153 User Manual
Hans Grohe Plumbing Product 98808000 User Manual
Hasbro Games 59917 User Manual
Heath Zenith Home Security System SL 6105 User Manual
Hotpoint Range LEB316 User Manual
HP Hewlett Packard Projector Ep9012 User Manual
Hubbell Electric Heater Company Water Heater EMV User Manual
Husqvarna Edger Edger Attachment User Manual
IBM Computer Monitor 21L4364 User Manual
IBM Switch Hub Switch User Manual