Heath Zenith Home Safety Product 3038361 User Manual

Motion Sensing Light Fixture with Accent Lighting  
Models 3038361/3038379  
2. Aiming  
Note: Installation of this light control should be done only by  
those with experience in 120 Volt household wiring. Some lo-  
cal codes may require that a licensed electrician install the light  
control.  
The coverage area for the sensor is shown in Figure 2. The sensor  
should be aimed so that the motion to be detected is in front of and  
across the coverage area. The sensor should be aimed looking out  
at a horizontal angle. To reduce false triggering, point the sensor  
away from traffic areas, air conditioners, dryer vents, water pools,  
or anything which may move or change temperature rapidly.  
This light control automatically turns on lights when motion is  
detected.  
Two lamp holders are provided. The lamp holders are rated at 150  
watts max. each.  
240°  
1. Installation  
Caution: Always turn the circuit breaker off when wiring the  
fixture.  
8 Ft.  
1. Remove the existing fixture.  
2. The plastic hanger can be used to hold the fixture while wiring.  
The small end of the plastic hanger can be threaded through the  
hole in the center of the cover plate. The small end then goes into  
one of the slots on the mounting strap.  
3. Connect the light control as shown in Figure 1:  
Black sensor wire to the black (HOT) house wire.  
White sensor wire to the white (NEUTRAL) house wire.  
100 Ft.  
Figure 2 Coverage Angles  
3. Testing  
Turn the power back on at the circuit breaker. Turn the light switch  
on.  
Note: When first turned on wait about 1 1/2 minutes for the circuitry  
White to white  
Black to black  
to calibrate.  
From  
Put the TIME switch on the bottom of the sensor in the TEST posi-  
tion.Youcannowwalkinfrontoftheunitandthelightswillcomeon  
for about 5 seconds. The TEST mode works both day and night.  
House  
Push the rubber  
plug firmly into  
place  
Walk through the coverage area and point the sensor to obtain the  
desired coverage area. Adjust sensitivity as needed. Use Range  
Boost only if required.  
House ground wire to green  
ground screw on fixture.  
4. Operation  
For motion sensing, put the ON-TIME switch on the bottom of the  
sensor in the 1, 5 or 20 minute position. When motion is detected,  
the lights will come on the selected time. Note: The photocell keeps  
the lights from turning on in daylight.  
Figure 1 Wiring at Junction Box Plate  
4. Attach the fixture to the mounting strap with the center mount-  
ing bolt. Use a weatherproof sealant to seal the fixture to the  
junction box.  
5. Install the protective lamp shields on the lamp holders by lining  
up the groves on the narrow end of the shields with the dimples  
in the lamp holders, push the shields into the lamp holders and  
turn clockwise slightly.  
6. Install the lamps in the lamp holders. Do not over tighten.  
7. Adjustment lamp holders. The lamps should be at least 1 inch  
away from the sensor.  
To keep lights on all night, flip the light switch off for 1 second  
then back on. Turning the light switch off for 1 second then back  
on will return the control to the motion sensing mode. At dawn, the  
control will return to the motion sensing mode and shut off.  
®
ForAccent Lighting, set the DualBrite switch to the 3, 6, or Dusk  
to Dawn setting. The lights will then turn on dim at sundown for the  
set time. When motion is sensed the lights will turn on full bright.  
Specifications:  
CAUTION: Do not mount the sensor above or touching the lamps  
(keep 1 inch or more from the lamps). The sensor bottom must  
be facing down for best coverage and to avoid water damage  
and electrical shock.  
Total Lighting Wattage.....................................................300 watts  
Lamp Holder Wattage .....................................150 watts max. each  
Range ......................... up to 70 ft.; up to 100 ft. with Range Boost  
Time Delay......................................................... 1, 5 or 20 minutes  
Accent Lighting Timer...........................3, 6 hours, Dusk-to-Dawn  
Note: For under-eave installation, rotate the sensor head 180° by  
bending the sensor towards the clamp bracket. Rotate the sensor  
bottom clockwise away from the bracket.  
Caution: This product is to be used with a U.L. listed rain tight  
or wet location suitable outlet box. Depending on the installation,  
additional hardware may be required.  
595-5754-03  
© 2008  
 

Groupe SEB USA T FAL Coffeemaker evolutive User Manual
Harbor Freight Tools Grinder 90003 User Manual
Harbor Freight Tools Saw 91939 User Manual
Hasbro Robotics 83178 User Manual
Heath Zenith Home Safety Product 2LBN2 User Manual
Heath Zenith Home Safety Product BL 2400 User Manual
HP Hewlett Packard Digital Camera R725 User Manual
HP Hewlett Packard Flat Panel Television HP LC3260N User Manual
HP Hewlett Packard Power Supply T2200 XR User Manual
IBM Laptop RT 686 User Manual