Honeywell Air Conditioner MN12CES User Manual

Portable Air Conditioner  
OWNER’S MANUAL  
Read these instructions before use  
Model: MN12CES / MN10CESWW  
Voltage rating: 120V~60Hz  
Power rating : 1100W (MN12CES)  
Power rating : 900W (MN10CESWW)  
Customer Support : 1-800-474-2147  
 
Made in China  
THANK YOU  
Congratulations on your purchase of this versatile Honeywell Portable Air Conditioner.  
Honeywell Portable Air Conditioners are ideal for spot cooling. The compressor, condenser  
and evaporator are housed in a compact unit. The air is filtered, dehumidified and cooled while  
a flexible air outlet hose sends heat outside. The air conditioner includes a window venting kit.  
No permanent installation is needed. The unit is easy to move from room to room and offers a  
truly flexible air conditioning solution.  
Auto Evaporation System - The unit automatically evaporates the condensate through the air  
outlet hose. There is no need to empty the drainage tank except in very high humidity conditions.  
Read and follow the instructions carefully.  
2
 
USER TIPS  
To ensure optimal efficiency of the product, keep doors and windows closed when it  
is used as an air conditioner or dehumidifier.  
If the product is being used with the fan function only, an open window could improve  
air circulation.  
Cooling and Dehumidifying Operation  
Fan Operation  
Important : Before installing the unit, place it UPRIGHT for 20 minutes  
before use to allow the refrigerant to stabilize.  
Follow installation instructions to set up the unit.  
Plug the unit into a properly grounded circuit.  
3
 
SAFETY  
READ AND SAVE THESE INSTRUCTIONS  
Improper handling can cause serious damage to the appliance.  
WARNING  
1. DO NOT operate the unit with a damaged plug or loose wall outlet. If the power  
cord is damaged, it must be replaced by the manufacturer or an authorized service agent.  
2. DO NOT cover the air intake and exhaust when in use.  
3. This appliance is not intended for use by children. Children should be supervised  
and should not play on or around the appliance.  
4. DO NOT place objects on or sit on the unit.  
5. Always turn off and unplug the unit when cleaning or servicing.  
6. If service is needed contact an authorized service agent.  
7. Unplug the unit when stored or not in use.  
4
 
SAFETY  
8. DO NOT run the power cord under carpeting and rugs.  
9. Use caution to prevent tripping on cord.  
10. DO NOT use in areas where gasoline, paint or other flammable goods are stored.  
11. Basic safety precautions should always be followed when using electrical appliances.  
5
 
PARTS DESCRIPTION  
6
7
2
1
3
5
10  
11  
8
9
4
1. Control Panel (Incl. Signal Receptor)  
2. Air Outlet  
3. Handle  
4. Casters  
5. Upper Drain Plug  
6. Air Filter  
7. Back Grill  
8. Lower Drain Plug  
9. Power Supply Cord  
10. Exhaust Hose Connector  
11. Remote Control  
Installation Kit :  
1. Window Bracket Kit............................. 1 Set  
2. Window Bracket Panel Adapter.......... 1 Piece  
3. Plastic Pin........................................... 2 Pieces  
4. Hose Connector.................................. 1 Piece  
5. Plastic Hose........................................ 1 Piece  
4
1
2
3
x 1  
x 1  
x 2  
x 1  
5
6
 
INSTALLATION  
1
Install the plastic hose with window bracket adapter and hose connector on both sides.  
Ensure proper fit on both ends.  
=
2
Adjust the window bracket as per width or height of your window and insert the plastic  
pins to fix at the desired position.  
Note : Do not install the window  
bracket to your window. This step is  
required only to adjust it to the  
size of your window. The bracket  
should be removed from the window  
after the size is adjusted.  
Plastic Pin  
Plastic Pin  
3
Connect the plastic hose to the hose connector on back of the unit. Push-in then rotate  
clockwise.  
7
 
INSTALLATION  
4
Connect the window bracket to the opposite end of the plastic hose. Ensure that  
all connections are tight and installed properly.  
5 Connect the window bracket to the window.  
6 The Portable Air Conditioner is now ready to use.  
8
 
INSTALLATION  
Note:  
1. The supplied exhaust hose can be extended from 12 inches (1 foot) to 47 inches  
(3.9 feet).  
2. Do not bend (to the extent shown below) the exhaust hose.  
A bent hose will block exhaust air and cause the unit to malfunction or shut-off.  
20”  
NOT RECOMMENDED  
RECOMMENDED  
Warning:  
The length of the exhaust hose is determined by the product specifications. Do not  
replace or lengthen it as this could cause the unit to malfunction.  
Make sure the back of the unit is at least 20 inches away from a wall.  
Do not place the unit in front of curtains or drapes as this could obstruct the  
airflow.  
9
 
USE & OPERATION  
Touch Screen Control Panel  
Warning Light (when flashing)  
Timer Control  
Power Control  
Mode Control  
Fan Speed Control  
Timer / Temperature  
Set Controls  
Power Control  
The Power Control turns the unit on and off.  
Fan Speed Control  
3 settings: High, Medium and Low.  
Mode Control  
3 settings: Cool, Dehumidify and Fan  
Timer Control  
Auto turn off:  
With machine in running mode, press timer button to select the  
number of hours you want the unit to run in air conditioning mode.  
Auto turn on:  
With machine in stand by mode, press the timer button to select  
the number of hours until you want the unit to automatically start  
running.  
A light will indicate which setting is currently being used.  
• Cooling Mode  
The unit works as an air conditioner. Adjust fan speed and air  
temperature to suit your desired comfort level. Temperature  
setting range is 61°F ~ 89°F  
• Dehumidifying Mode  
Temperature / Timer Set Controls  
Air is dehumidified as it passes through the unit, without being in  
full cooling mode. If room temperature is higher than 77°F  
fan speed can be adjusted; otherwise fan speed is preset "LOW".  
Note : If the unit will be used mainly as a dehumidifier, do not  
connect the exhaust hose and let the warm air return in the  
room. Continuous drainage is then necessary and more  
efficient (refer page 14, Continuous Draining).  
• Used for adjusting the timer and thermostat.  
• The default display is room temperature.  
• In cooling mode, when “ “ or ““ button is pressed, the set  
temperature is displayed and may be adjusted.  
After 10 seconds the display will revert back to room temperature.  
Temperature is only adjustable in cool mode.  
The time is adjustable between 1~24 hours.  
Note : By pressing both “ “ / ““ set buttons at the same  
time, the display will toggle between Celsius and Fahrenheit.  
• Fan Mode  
For air circulation without cooling.  
Warning Light  
Condensed water may accumulate in the unit. If the internal tank  
becomes full, the Power Light will flash and the unit will not  
operate until the unit has been drained (refer page 14, Water  
Condensation Drainage).  
After switching the air conditioner off, you must wait 3 minutes before switching it back on again.  
 
10  
USE & OPERATION  
Remote Control  
The functions work the same as the portable air conditioner’s touch  
controls. All key functions can be accessed from the remote control.  
Temperature / Timer Set  
Control  
Used for adjusting the timer  
and temperature.  
The default display is room  
temperature.  
Power Control  
ON / OFF  
When “ or ““ key is  
pressed in cool mode, the set  
temperature is displayed and  
may be adjusted. After 10  
seconds the display will revert  
back to room temperature.  
Timer setting is available from  
1-24 hours by pressing the  
key “ or ““  
Fan Speed Control  
HIGH MEDIUM LOW  
Timer Control  
In running mode:  
Auto switch off  
In stand-by mode:  
Auto switch on  
Press “ or ““ button  
to adjust the time  
Mode Control  
Press this button to change the  
operation mode in the order of:  
Cool  
Dehumidify  
setting for 1 hour intervals.  
Fan  
Note :  
Do not place the remote control in direct sunlight.  
11  
 
USE & OPERATION  
Battery Installation: Remove the cover on the back of the remote control and insert two AAA  
batteries with ‘‘+’’ and ‘‘-’’ pointing in the proper direction.  
Caution  
• Use only two AAA or IEC R03 1.5V batteries.  
• Remove the batteries if the remote control is not in use for a month or longer.  
• All batteries should be replaced at the same time, do not mix with old batteries.  
• Properly dispose of used batteries.  
12  
 
CLEANING & MAINTENANCE  
Appliance Maintenance:  
1. Turn off the appliance before disconnecting the power supply.  
2. Always clean the appliance with a soft dry cloth.  
Air Filter Maintenance:  
The air filter should be cleaned every two weeks.  
Clean it as follows:  
1. Turn off the appliance and remove the air filter. (refer to page 5, #6)  
2. Rinse it in lukewarm water. After cleaning, dry in a shaded and cool place, then  
reinstall.  
Maintenance After Use:  
1. If the appliance will not be used for a long time, be sure to drain the left-over  
water condensation.  
2. Remove the lower drain plug (refer to page 14) and use a shallow pan to collect the  
water.  
3. To dry excess moisture, run the unit in fan mode for 30 minutes before storing.  
4. Clean and reinstall air filter.  
5. Remove air hose and window bracket and store with the portable air conditioner.  
13  
 
WATER CONDENSATION DRAINAGE  
Water Condensation Drainage  
When there is excess water condensation inside the unit, the air conditioner stops running and  
shows a warning light (refer to page 10). This warning light indicates that the water condensation  
needs to be drained using the following procedures:  
Manual Draining  
Water may need to be drained in high humidity areas  
1. Unplug the unit from power source.  
2. Place a shallow pan under the lower drain plug. See diagram.  
3. Remove the lower drain plug.  
Lower  
Drain Plug  
4. Water will drain out and collect in the shallow pan.  
5. After the water is drained, replace the lower drain plug firmly.  
6. You can now turn on the unit.  
Shallow Pan  
(Not included)  
Continuous Draining  
While using the unit in dehumidifier mode, continuous drainage is  
recommended.  
1. Unplug the unit from the power source.  
Upper  
Drain Plug  
2. Remove the upper drain plug. While doing this operation some  
residual water may spill so please have a pan to collect the water.  
3. Connect the drain connector to a ¾” hose (not included).  
See diagram.  
4. The water can be continuously drained through the hose into a  
floor drain or bucket.  
Water Drain Pipe  
5. You can now turn on the unit.  
14  
 
TROUBLESHOOTING GUIDE  
The following troubleshooting guide addresses the most common problems. If problems  
persist, call customer service. Unplug and disconnect the appliance from the power  
source before attempting to troubleshoot.  
Problem  
Possible Cause  
No electricity.  
Batteries in the remote control need  
to be replaced.  
Solution  
Check for power.  
• Change remote control batteries.  
The air conditioning  
unit does not start  
The power cord is not properly  
plugged in.  
Remove and reconnect the power  
cord.  
The safety GFI plug has tripped.  
Reset the safety GFI plug, if  
problem persists contact our  
customer support.  
The thermostat temperature setting  
is too close to room temperature.  
Air outlet is blocked.  
Lower the set temperature.  
Make sure the exhaust hose is  
Runs a short while  
only  
properly connected.  
There are tight bends in the air  
exhaust hose.  
Connect exhaust hose as per  
instructions on page 9.  
A door or window is open.  
Make sure the window or door  
is closed.  
The air filter is dirty.  
The exhaust hose is detached.  
Clean the air filter  
Reinstall exhaust hose properly  
(refer to page 9, Installation)  
Reduce temperature setting on  
control panel.  
Runs but no cooling  
Temperature setting is too high.  
Air outlet or intake is blocked.  
• Remove blockage.  
Will not run and  
water full indicator  
light is ON  
Drain the water. (refer to page 14,  
Water Condensation Drainage).  
Excess water condensation inside  
the tank.  
15  
 
TECHNICAL SPECIFICATIONS  
Description of Product  
Model  
Portable Air Conditioner  
Portable Air Conditioner  
MN10CESWW  
120 V~ 60 Hz  
900W  
MN12CES  
120 V~ 60 Hz  
1100W  
Voltage/Frequency  
Power Consumption  
Cooling capacity  
Dehumidifying capacity  
Refrigerant Type  
Timer  
12000 BTU  
70 pints/24 hours  
R-410A  
10000 BTU  
68 pints/24 hours  
R-410A  
24 hour (ON / OFF)  
24 hour (ON / OFF)  
15.2 X 18.1 X 29.3 inches  
15.2 X 18.1 X 29.3 inches  
Dimensions (W) x (D) x (H) (inches)  
Weight (Kg)  
68.3 lbs (31 Kg)  
63.9 lbs (29 Kg)  
Electrical products should be properly disposed.  
Please recycle where facilities exist. Check with your local authority  
or retailer for recycling.  
16  
 
SERVICE AND WARRANTY  
5-YEAR LIMITED WARRANTY  
1st year parts and labor.  
5 years on all parts of the sealed system, consisting of the compressor,  
evaporator, condenser and factory connected refrigerant tubing.  
A. This warranty does not apply to any damage resulting from abusive, unreasonable use or  
damage. Defects that are the result of normal wear and tear will not be considered  
manufacturing defects under this warranty.  
JMA NORTH AMERICA LLC IS NOT LIABLE FOR INCIDENTAL OR CONSEQUENTIAL  
DAMAGES OF ANY NATURE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR  
FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION  
TO THE DURATION OF THIS WARRANTY.  
Some jurisdictions do not allow the exclusion or limitation of incidental or consequential  
damages or limitations on how long an applied warranty lasts, so the above limitations or  
exclusions may not apply to you. This warranty gives you specific legal rights, and you  
also may have other rights which vary from jurisdiction to jurisdiction. This warranty  
applies only to the original purchaser of this product from the original date of purchase.  
B. At its option, JMA NORTH AMERICA LLC will repair or replace this product if it is found to be  
detective in material or workmanship.  
C. This warranty does not cover damage resulting from any unauthorized attempts to repair or  
from any use not in accordance with the instruction manual.  
17  
 
SERVICE AND WARRANTY  
D. Please read the Instruction Manual carefully before setting up or using this product. If you  
believe this product to be suffering from a manufacturing fault, or if you have inquiries about  
this product, please contact our Customer Support:  
CUSTOMER SUPPORT  
JMA North America LLC  
Ramsey, New Jersey 07446  
Phone: 800-474-2147  
When contacting our Customer Support, please have the information below along with the  
proof of purchase. All warranty requests must be accompanied by a proof of purchase, which  
is a copy of the original receipt.  
Model  
: .......................................................................................................................  
Date of purchase : .......................................................................................................................  
Purchased from : .......................................................................................................................  
18  
 
MN12CES&MN10CESWW_IM_Eng_USA_10  
January 2013  
© 2013 AirTek Int’l Corp. Ltd.  
Distributor:  
JMA North America LLC  
Ramsey New Jersey 07446  
Customer Support: 1-800-474-2147  
(JMATEK Int’l Group of Companies)  
The Honeywell Trademark is used under license from  
Honeywell International Inc.  
Honeywell International Inc. makes no representation or  
warranties with respect to this product.  
This product is Manufactured by Airtek International  
Corporation Limited.  
 

Graco Cell Phone M10E User Manual
Graco Food Saver 312348B User Manual
Grizzly Impact Driver H8119 User Manual
Haier Refrigerator HVFE024BBB User Manual
Havis Shields Network Card C 3075 3S User Manual
Hotpoint Ventilation Hood KSO89CX S User Manual
Hotpoint Washer Dryer WDL540 P G A K User Manual
HP Hewlett Packard Network Cables HP 85025C User Manual
Hypertec Carrying Case Adelphi 17 User Manual
IBM Laptop 770Z User Manual