K3636V3 9/04 Rev. A
ADEMCO 5804BDV
TWO-WAY WIRELESS KEY with VOICE STATUS
USER GUIDE
About the 5804BDV
The 5804BDV is a four-button remote control for your alarm system. It can send a command to the alarm system, such as to arm or disarm,
as well as receive system status. Two LEDs and a speaker indicate system status. The 5804BDV is typically used for arming, disarming, and
home automation. Check with your installer to understand which functions the buttons have been assigned on your unit.
Operating the Buttons
Activating a Function
To activate a function, press and hold the appropriate button down until the yellow LED flashes, and then release it.
Requesting System Status
You can check system status before arming or disarming your system.
Check your system status by momentarily pressing and releasing any button. The yellow LED will flash after you release the button. After a
second or two, the 5804BDV will display the system status through the LEDs and speaker (see the System Status Indications Table, below).
If the 5804BDV does not receive system status from the panel for approximately 5 seconds, it will shut itself down. It will also shut itself down
if you do not press a button within 5 seconds of receiving a status update.
System Status Indications Table
LED
LED Condition
Speech
System Status
Red
On Steady
System Armed Away
Armed Away or Maximum
System Armed Stay
Armed Stay or Instant
Fire Alarm in progress
Armed, Burglary Alarm in progress
Alarm Memory
Flashing
Fire Fire Zone (Faulted Zone)
Alarm Alarm Zone (Faulted Zone)
Alarm Alarm Zone (Faulted Zone)
System Disarmed Ready To Arm
Green
On Steady
Flashing
Flashing
Disarmed, Ready to Arm
System Disarmed Not Ready To Arm System Not Ready, Zones Faulted
Yellow (right)
Red & Green
—
—
Indicates RF transmission
In Enter House ID Mode
In Set Volume Level Mode
AC Loss Condition
Alternately
Flashing
NA
NA
System AC Loss
Low Battery
Low Battery Condition
Multiple Button Operations
A + C Button Pair
B + D Button Pair
The 5804BDV should not be used
for silent panic operation.
WARNING!
The 5804BDV can generate the same responses as keypad panic
key pairs of [*] + [#] and [*] + [1] by depressing “A” + “C” and “B” +
“D” button pairs, respectively. You must depress the button pair
for at least 2 seconds for the 5804BDV to recognize the button pair
command. These button pairs allow you to activate panic, fire,
and medical alarms depending on control panel programming.
5804BDV-005-V0
Adjusting the Volume Level
To enter the Volume Level mode, press and hold down the A, B, and D buttons at the same time until the unit’s red and green LEDs flash
alternately. If no button is pressed within 5 seconds, the unit will automatically shut down and no change to the volume level is made. Press
the A button for low volume level, the B button for mid volume level, and the C button for maximum volume level. You will hear the word
“Alarm” at the selected volume. Then press the D button to accept the selected sound level. Note that volume level affects the life of the
battery. Use low volume for maximum battery life.
|