Dimensions (in inches)  
7-1/2  
Amp Rating  
7
29-7/8  
7-1/2  
5
240V  
208V  
10.1  
8.7  
3-1/2  
2-1/4  
REAR  
WALL  
Breaker Size  
2-1/4  
40 Amps†  
CENTER LINE  
Note: Check local codes for required breaker size.  
Note: 30" Electric Ranges conform to U.L. requirements for  
0" spacing from walls below countertops. Allow 1-1/2" spacing  
from the side of the range to adjacent vertical walls above the  
cooktop surface.  
46-1/8  
The range may be placed with  
0" clearance (flush) at the back  
wall and side walls if the range  
side trims extend beyond the  
cabinet fronts at least 1/4".  
Self-Clean models only  
1/4†  
Receptacle Locations: Locally approved flexible service cord  
or conduit must be used because terminals are not accessible  
after range installation. See shaded area in drawing for location  
of electrical outlet box. Recommended outlet locations allow  
range to be installed directly against rear wall.  
Installation Information: Before installing, consult installation  
instructions packed with product for current dimensional data.  
26-3/8*  
46-3/8  
*Dimension from wall to front of closed oven door.  
Dimension from wall to the front of closed oven  
door handle is 28-1/2".  
All Hotpoint ranges are equipped  
with an Anti-Tip device. The  
Listed by  
Underwriters  
Laboratories  
installation of this device is an  
important, required step in the  
installation of the range.  
Specification Revised 12/08  
420406  
 

Grizzly Nail Gun H6141 User Manual
Grizzly Paint Sprayer H6330 User Manual
Grizzly Treadmill G0695 User Manual
Grundig CRT Television MW70 150 8 DOLBY User Manual
Haier DVD Player DTA 1486 User Manual
Hamilton Beach Oven 22988 User Manual
Havis Shields Fan GSM30027 User Manual
Hoshizaki Ice Maker KML F SERIES User Manual
HP Hewlett Packard All in One Printer 4500 User Manual
HP Hewlett Packard Laptop 376311 001 User Manual