Hubbell Switch 4292 User Manual

Hubbell Industrial Controls, Inc.  
4292  
Lifting Magnet Controllers  
Type 4292 Compact Controller for Scrap Yards  
Specification/Price Sheet • August 2008 • Replaces Jan 2008  
Description  
The Type 4292 Yard-  
Automatic  
Discharge  
Type  
master  
Controllers  
incorporated heavy-duty  
time proven components  
arranged to provide  
optimum control of your  
lifting magnets.  
Controllers  
The Type 4292 Yardmaster  
Automatic Discharge Type  
Lifting Magnet Controller  
provides a fast and clean  
release of mag-net loads  
by applying full voltage  
reverse current to the  
magnet. The full voltage  
re-verse current feature  
permits the operator to  
promptly return for another  
lift.  
A mechanically rugged  
high thermal capacity  
discharge  
varistor  
assembly is permanently  
connected in parallel  
with the magnet and  
provides  
a
safe dis-  
charge path for the  
stored magnetic energy.  
With Yardmaster mag-  
net controllers, induced  
voltage cannot return  
to the line, permitting  
rectified power supplies  
to be used without  
the added expense of  
special protective loads  
or bypass circuits.  
The drop contactor is  
under the control of the  
operator’s Master Switch  
and the dis-charge sensor  
Features  
Automatic Discharge  
Rated 250 VDC @ 5-100 amps  
Front-Wired Front-Removable components  
module (DSM).  
When  
Mechanically interlocked “Liftand “Drop”  
NEMA rated mill duty contactors  
the operator’s Master  
Switch signals the magnet  
Permanently connected 700V discharge  
path completely independent from the  
line that protects magnet and generator controller to drop the load,  
High-Thermal capacity varistor discharge  
path  
the “Lift” contactors (L)  
open. The stored magnet  
Peak magnet induced voltage limited to  
energy is dissipated in the  
dis-charge varistor. When  
the discharge voltage  
declines to approximately  
300V, the DSM energizes  
the drop relay (DR) which  
in turn enables the drop  
contactor (D) to close  
applyingfullvoltagereverse  
cur-rent to the magnet and  
begin the adjust-able time  
reverse current cycle. After  
the completion of the timed  
reverse cycle the drop  
relay and drop contactor  
are deenergized.  
under 700 Volts  
Application  
Long electrical contact life  
Minimum Maintenance  
Dribble control - Standard  
The Type 4292 Yard-  
master Controllers are  
suited for many uses  
from light scrap handling  
to the handling of heavy  
billets or plates. It may  
be used with all types  
and makes of DC lifting  
magnets.  
Ventilated indoor/outdoor NEMA 3R  
enclosure  
 

Grizzly Sander 9962ZX User Manual
Harbor Freight Tools Nail Gun 66872 User Manual
Hasselblad Camcorder H4D200MS User Manual
Hoshizaki Ice Maker IM 51BAE User Manual
Hotpoint Electric Pressure Cooker EW93 User Manual
Hotpoint Range RB757CH User Manual
HP Hewlett Packard Photo Printer Z2100 610 User Manual
HP Hewlett Packard Tablet D3H90UT User Manual
Husqvarna Snow Blower 924SB User Manual
hussman Cookware SCSS User Manual