HP Hewlett Packard Computer Accessories AA RTDKA TE User Manual |
application notes
hp OpenView
storage management appliance
software
event code definitions
Product Version: 2.0
First Edition (December 2002)
Part Number: AA-RTDKA-TE
This document describes the event codes used in notification messages generated by the HP OpenView Storage
Management Appliance software V2.0.
Additional information and other HP OpenView documentation are available at:
Application Notes Contents
Application Notes Contents
These Application Notes provide listings of the various event codes displayed by the HP
OpenView Storage Management Appliance. The event codes are defined and discussed in the
following sections:
■
■
■
■
■
■
■
■
Intended Audience
This document is intended for customers who purchase the Storage Management Appliance
software V2.0. It has been developed for use by storage and system administrators who are
experienced with:
■
Managing storage area networks (SANs).
Running a Storage Management Appliance.
■
Related Storage Management Appliance Software V2.0 Documentation
The following list includes documentation related to the Storage Management Appliance
software V2.0:
■
■
■
■
HP OpenView Storage Management Appliance Software V2.0 Update Installation Card
HP OpenView Storage Management Appliance Software V2.0 User Guide
HP OpenView Storage Management Appliance Software V2.0 Release Notes
HP OpenView Storage Management Appliance Software V2.0 Installing Antivirus and
Backup Software Application Notes
■
■
■
■
■
HP OpenView Storage Management Appliance Software V2.0 Online Help
HP OpenView Automation Manager Script Development Guide
HP StorageWorks HSG Element Manager User Guide
HP StorageWorks HSV Element Manager User Guide
HP StorageWorks SAN Design Reference Guide
Additional documentation, including white papers and best practices documents, is available
from the HP website at:
.
Storage Management Appliance Software Event Code Definitions Application Notes
3
Introduction
Introduction
The Storage Management Appliance can generate notification messages to any number of
users in response to events. A notification message, including the source of the event, date,
time, event code, and event description, can be sent to a standard e-mail address or to an e-mail
pager address. This document provides a complete list of the events logged by the Storage
Management Appliance.
The lists of events are presented in tables with one table for each application or vendor.
Each table contains the following columns:
■
Event ID—Numeric code used to identify the event specific to the event’s source.
■
Event Code—Hexadecimal code used to identify an event type in notification messages
and in the Storage Management Appliance Event Log or Audit Log.
■
■
Severity—Single digit code indicating the event severity or potential impact on Storage
Management Appliance operations (see Table 1 for more information).
Description—Text describing the event. Event details are provided by the source of the
event. In this document, event details are expressed as %1, %2, etc.
Table 1 describes the severity codes used for event codes.
Table 1: Severity Codes
Event Severity
Code
Name
Unknown
Other
Description
Severity cannot be determined.
0
1
Can be one of several possible severity conditions.
Refer to the event code description for details.
2
3
4
Information
Warning
Minor
Event is generally part of normal operation.
Further action is optional
Further action is required but the situation is not
considered serious.
5
6
Major
Action should be taken immediately.
Critical
Action required to avoid a significant impact on
operations.
7
Fatal
An error occurred and no action can be taken to avoid
or mitigate the immediate impact.
4
Storage Management Appliance Software Event Code Definitions Application Notes
Storage Management Appliance Event Codes
Storage Management Appliance Event Codes
The Storage Management Appliance’s core services—discovery, event notification, and
automation—generate the events listed below. The system records these events in the Storage
Management Appliance Event Log.
Table 2: Storage Management Appliance Event Codes
Event
ID
Event
Code
Severity
Description
202
203
204
205
206
408
880A00CA
880A00CB
880A00CC
880A00CD
880A00CE
880A0198
2
2
2
2
2
3
Discovery %1 started.
Discovery %1 completed.
New device found: %1.
Device %1 unreachable for %2 day(s).
Device %1 unreachable for %2 week(s).
Notification for user %1 has been disabled. This user was the sole
recipient of event notifications from %2.
700
880A02BC
2
Received a SNMP Trap from %1. The enterprise OID is %2,
GenericTrap is %3, SpecificTrap is %4.
701
702
703
704
800
880A02BD
880A02BE
880A02BF
880A02C0
880A0320
3
6
3
6
7
The Management Appliance event log is 80% full.
The Management Appliance event log is full.
The Management Appliance audit log is 80% full.
The Management Appliance audit log is full.
Automation Manager experienced the following abnormal
operation: %1
801
802
880A0321
880A0322
7
2
Automation Manager experienced the following database failure:
%1
Event process %1 ran in policy %2 on Management Appliance %3
completed with state %4. Process started on %5 and ended on %6
with %7 return code. Policy finished with status: %8
803
804
880A0323
880A0324
2
3
Event process %1 ran in policy %2 triggered on an event %3
logged by %4.
Event process %1 ran in policy %2 on Management Appliance %3
completed with state %4. Process started on %5 and ended on %6
with %7 return code. Policy finished with status: %8
805
806
880A0325
880A0326
2
3
Action process %1 ran in policy %2 on Management Appliance %3
completed with state %4. Process started on %5 and ended on %6
with %7 return code. Policy finished with status: %8
Action process %1 ran in policy %2 on Management Appliance %3
completed with state %4. Process started on %5 and ended on %6
with %7 return code. Policy finished with status: %8
807
808
880A0327
880A0328
2
2
%1 policy has been submitted successfully.
Event process %1 in policy %2 was satisfied when the %3 value of
enterprise OID %4 was received in a SNMP Trap.
1014
1015
1016
1017
880A03F6
880A03F7
880A03F8
880A03F9
2
2
2
2
%1 service started.
%1 service stopped.
%1 service: Handler not installed.
%1 service: Bad service request.
Storage Management Appliance Software Event Code Definitions Application Notes
5
Storage Management Appliance Audit Codes
Storage Management Appliance Audit Codes
The Storage Management Appliance generates audits in response to most user-initiated
operations. Activities such as creating or running a discovery generate audits that are recorded
in the Storage Management Appliance Audit Log.
Table 3: Storage Management Appliance Audit Codes
Event ID Event Code Severity
Description
Installation of %1 on appliance %2.
Removal of %1 from appliance %2.
Deletion of %1 device.
100
101
150
151
152
207
208
209
210
211
212
213
300
8C0A0064
8C0A0065
8C0A0096
8C0A0097
8C0A0098
8C0A00CF
8C0A00D0
8C0A00D1
8C0A00D2
8C0A00D3
8C0A00D4
8C0A00D5
8C0A012C
2
2
2
2
2
2
2
2
2
2
2
2
2
Launch of %1 URL.
Modification of %1 device.
Creation of discovery named %1.
Deletion of discovery named %1.
Modification of discovery named %1.
Enabling of schedule for discovery named %1.
Disabling of schedule for discovery named %1.
Discovery named %1 requested to start.
Discovery named %1 requested to stop.
Creation of remote access entry for Host: %1, Application:
%2, Domain Name: %3, Username: %4.
301
302
8C0A012D
8C0A012E
2
2
Modification of remote access entry for Host: %1,
Application: %2, Domain Name: %3, Username: %4.
Deletion of remote access entry for Host: %1, Application:
%2, Domain Name: %3, Username: %4.
303
304
305
306
307
308
309
310
311
312
400
401
402
403
404
405
8C0A012F
8C0A0130
8C0A0131
8C0A0132
8C0A0133
8C0A0134
8C0A0135
8C0A0136
8C0A0137
8C0A0138
8C0A0190
8C0A0191
8C0A0192
8C0A0193
8C0A0194
8C0A0195
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Modification of %1 license.
Creation of %1 license.
Deletion of %1 license.
Modification of %1 license.
Download of %1 license.
Clearing of %1 license.
Download of event log.
Clearing of event log.
Modification of event log properties.
Acknowledgement of events in the event log.
Deletion of user %1.
Importing of user %1.
Creation of user %1.
Changing password for user %1.
Modification of user %1 properties.
Modification of user %1 notification properties for the
following devices: %2.
406
8C0A0196
2
Transfer of user %1 notification settings to user %2.
6
Storage Management Appliance Software Event Code Definitions Application Notes
Storage Management Appliance Audit Codes
Table 3: Storage Management Appliance Audit Codes (Continued)
Event ID Event Code Severity
Description
407
8C0A0197
2
Deletion of notification settings from user %1 and transferred
to user %2.
500
501
8C0A01F4
8C0A01F5
2
2
Starting backup to network share %1.
Completion of backup operation that was started to network
share %1. See %2 file on Management Appliance %3 for
details.
502
8C0A01F6
2
Cancellation of backup operation that was started to network
share %1. See %2 file on Management Appliance %3 for
details.
600
601
8C0A0258
8C0A0259
2
2
Starting restore operation from network share %1.
Completion of restore operation that was started to network
share %1. See %2 file on Management Appliance %3 for
details.
602
8C0A025A
2
Cancellation of restore operation that was started from
network share %1. See %2 file on Management Appliance
%3 for details.
603
604
900
901
904
905
906
8C0A025B
8C0A025C
8C0A0384
8C0A0385
8C0A0388
8C0A0389
8C0A038A
2
2
2
2
2
2
2
Clearing of backup log %1.
Clearing of restore log %1.
Starting %1.
Stopping %1.
Changing date/time to %1.
Changing time zone to %1.
Modification of SNTP time server - Enabled: %1, Server:%2,
Frequency:%3.
950
951
952
953
954
960
961
962
963
964
965
970
971
972
980
981
982
1000
1001
8C0A03B6
8C0A03B7
8C0A03B8
8C0A03B9
8C0A03BA
8C0A03C0
8C0A03C1
8C0A03C2
8C0A03C3
8C0A03C4
8C0A03C5
8C0A03CA
8C0A03CB
8C0A03CC
8C0A03D4
8C0A03D5
8C0A03D6
8C0A03E8
8C0A03E9
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
Launching of HSV element manager.
Launching of HSG Element Manager.
Launching of VersaStor.
Launching of Automation.
Launching of Management Agents.
Launching of Network View.
Launching of Secure Path Manager.
Launching of Data Replication Manager.
Launching of Enterprise Volume Manager.
Launching of Storage Allocation Reporter.
Launching of Storage Provisioner.
Modification of IP address configuration.
Modification of DNS server configuration.
Modification of WINS server configuration.
Modification of Administration Web Site properties.
Modification of Global Network settings.
Modification of Telnet Administration configuration.
Changing Management Appliance name to %1.
Changing Management Appliance membership to
workgroup %1.
Storage Management Appliance Software Event Code Definitions Application Notes
7
Storage Management Appliance Audit Codes
Table 3: Storage Management Appliance Audit Codes (Continued)
Event ID Event Code Severity
Description
1002
8C0A03EA
2
Changing Management Appliance membership to domain
%1.
1003
1004
1005
1006
1010
8C0A03EB
8C0A03EC
8C0A03ED
8C0A03EE
8C0A03F2
2
2
2
2
2
Shutdown of Management Appliance.
Changing domain/workgroup membership.
Restarting Management Appliance.
Scheduling Management Appliance for %1.
Configuration of Management Appliance as the first domain
controller in the new forest, %1. The new domain name is
%2.
1011
1012
8C0A03F3
8C0A03F4
2
2
Configuration of Management Appliance as the first domain
controller in a new domain tree. The name of the new
domain is %1 and has trust link with %2.
Configuration of Management Appliance as the first domain
controller in a new domain. The name of the new domain is
%1 and is created in %2 domain.
1013
1020
8C0A03F5
8C0A03FC
2
2
Configuration of Management Appliance as an additional
domain controller for the domain %1.
Modification of notification properties for event code %1 on
%2.
1021
1022
1030
1031
1032
1033
1040
1041
1042
1050
1055
1056
8C0A03FD
8C0A03FE
8C0A0406
8C0A0407
8C0A0408
8C0A0409
8C0A0410
8C0A0411
8C0A0412
8C0A041A
8C0A041F
8C0A0420
2
2
2
2
2
2
2
2
2
2
2
2
Configuration of notification for the following devices: %1.
Clearing of notification settings for the following devices: %1.
Download of audit log.
Clearing of audit log.
Modification of audit log properties.
Acknowledgement of audits in the audit log.
Adding of trap recipient %1.
Removal of trap recipient %1.
Modification of trap recipient %1.
Setting SMTP server to %1 with IP address: %2.
Logging in of user.
Logging out of user.
8
Storage Management Appliance Software Event Code Definitions Application Notes
NetApp Filers Event Codes
NetApp Filers Event Codes
The following events are generated by NetApp Filer devices and are recorded in the Storage
Management Appliance Event Log. A number of these events are associated with user-defined
traps and most indicate a condition that is likely to have a negative impact on operations. A
small number of events mark a return to normal operation after some period of abnormal
operation.
The Storage Management Appliance supports the NetApp MIB version 1.2.
Table 4: NetApp Filer Event Codes
Event
Event ID
Code
880E0064
880E0065
Severity
Description
An unknown trap event was received.
100
2
3
101
A polling-style trap built by the user using the SNMP traps
command on the filer.
102
103
104
880E0066
880E0067
880E0068
5
4
7
Disk Health Monitor reported a Disk Degraded-I/O Event.
Disk Health Monitor reported a Disk Predictive-Failure Event.
A user-defined trap indicating an extremely urgent situation,
usually indicating that the system has failed and is shutting
down.
105
106
107
108
109
880E0069
880E006A
880E006B
880E006C
880E006D
5
6
5
4
2
A user-defined trap indicating a condition that should be
corrected immediately, such as a failed disk.
A user-defined trap indicating a critical condition, such as a
hard device error.
A user-defined trap indicating an error condition, such as a
mistake in a configuration file.
A user-defined trap indicating a condition which is not an error,
but which may require special handling.
A user-defined trap meant to provide information, such as an
hourly uptime message.
110
111
880E006E
880E006F
1
7
A user-defined trap used for debugging purposes.
System is shutting down because the system has been running
in degraded mode for 24 hours.
112
113
114
880E0070
880E0071
880E0072
5
2
7
One or more disks failed.
The failed disks have been repaired.
Critical chassis or cpu fans have failed and the system is
shutting down.
115
116
117
118
880E0073
880E0074
880E0075
880E0076
5
3
2
7
One or more chassis fans failed.
One or more chassis or cpu fans are in warning state.
All fans are repaired.
Critical power supplies or power rails failed and the system is
shutting down.
119
120
121
880E0077
880E0078
880E0079
5
3
2
One or more redundant power supplies failed.
One or more power supplies or power rails in warning state.
Previously-failed power supplies or power rails have been
repaired.
122
123
880E007A
880E007B
4
2
CPU utilization exceeds 90 percent.
CPU utilization has dropped back below 90 percent.
Storage Management Appliance Software Event Code Definitions Application Notes
9
NetApp Filers Event Codes
Table 4: NetApp Filer Event Codes (Continued)
Event
Code
880E007C
880E007D
880E007E
Event ID
124
Severity
Description
The NVRAM battery is fully discharged.
The charge in the NVRAM battery is low.
5
4
5
125
126
A node in a Cluster FailOver configuration failed. Its partner
will assume service for the failed node.
127
128
129
130
131
132
880E007F
880E0080
880E0081
880E0082
880E0083
880E0084
5
2
5
4
2
7
The partner has taken over for a failed cluster node.
A cluster node has resumed operation.
At least one volume is more than 98 percent full.
At least one volume is more than 95 percent full.
All volumes are now under 95 percent full.
System temperature is too high to continue operating. The
system is shutting down.
133
134
135
880E0085
880E0086
880E0087
4
2
5
System temperature is too high and in the warning level.
System temperature has returned to an acceptable value.
A disk storage shelf reported a fault, probably due to a
problem with drive placement, fans, power, or temperature.
136
137
880E0088
880E0089
2
7
A previously-reported shelf fault is now corrected.
The appliance’s overall status changed to ‘nonRecoverable’,
indicating a problem so severe that the appliance is shutting
down.
138
139
880E008A
880E008B
6
4
The appliance’s overall status changed to ‘critical’, indicating a
problem that needs immediate attention.
The appliance’s overall status changed to ‘nonCritical’,
indicating a problem that needs attention.
140
141
142
143
144
145
146
880E008C
880E008D
880E008E
880E008F
880E0090
880E0091
880e0092
2
2
2
2
2
2
2
The appliance’s overall status returned to normal.
Cold Start.
Warm Start.
Link Down: %1
Link Up: %1
Authorization failure.
EGP Peer down: %1
10
Storage Management Appliance Software Event Code Definitions Application Notes
HP StorageWorks and McData Switch Event Codes
HP StorageWorks and McData Switch Event Codes
The following events are generated by HP StorageWorks switches and McData switches and
are recorded in the Storage Management Appliance Event Log. Many of these event types
have several possible states and each state has an appropriate severity code.
The Storage Management Appliance supports the following StorageWorks and McData MIB
versions:
■
■
■
V1.9 for the ED-5000 series
V1.10 for the EF-6000 series
V1.0 for the ES-1000 series
Table 5: HP StorageWorks and McData Event Codes
Event
ID
Event
Code
Possible States Severity
Description
100
101
880C0064
880C0065
N/A
2
An unknown trap event was received.
online
offline
testing
faulty
2
5
2
7
0
B_Port Index %2 changed state to %1.%n
A es1000PortBportScn is generated whenever
a B_Port changes its operational state.
unknown
102
103
880C0066
880C0067
online
offline
testing
faulty
2
5
2
7
0
H_Port Index %2 changed state to %1.%n
A es1000PortHportScn is generated whenever
a H_Port changes its operational state
unknown
active
2
2
7
Component Code %2 has changed state to
%1.%n
A es1000CompScn is generated whenever a
COMPONENT status changes its operational
state.
updatebusy
failed
unknown
0
104
105
106
107
880C0068
880C0069
880C006A
880C006B
online
offline
testing
faulty
2
5
2
7
0
Port Index %2 changed state to %1.%n
An ed5000PortScn(1) is generated whenever
a Fc_Port changes its operational state.
unknown
active
2
3
2
7
0
FRU Code %2 has changed state to %1.%n
An ed5000FruScn(2) is generated whenever a
FRU status changes its operational state.
backup
updatebusy
failed
unknown
online
offline
testing
faulty
2
5
2
7
0
Port Index %2 changed state to %1.%n
An ef6000PortScn(1) is generated whenever a
Fc_Port changes its operational state.
unknown
active
2
3
2
7
0
FRU Code %2 has changed state to %1.%n
An ef6000FruScn(2) is generated whenever a
FRU status changes its operational state.
backup
updatebusy
failed
unknown
Storage Management Appliance Software Event Code Definitions Application Notes
11
HP StorageWorks and McData Switch Event Codes
Table 5: HP StorageWorks and McData Event Codes (Continued)
Event
ID
Event
Code
Possible States Severity
Description
108
880C006C
N/A
2
Device WWN: %1 currently attached to Port
%2 has either successfully connected or is
currently being rejected due to a Port Binding
violation.%n
An ef6000PortBindingViolation(3) is
generated whenever the switch detects that a
port binding violation occurs.
109
880C006D
N/A
2
Threshold Alert.%n
ef6000PortIndex: %1%n
ef6000TAIndex: %2%n
An ef6000ThresholdAlert(4) is generated
whenever a threshold alert occurs.
113
115
117
119
121
123
880C0071
880C0073
880C0075
880C0077
880C0079
880C007B
informational
informational
warning
2
2
3
2
3
3
Cold Start.
Warm Start.
Link Down: %1.
Link Up: %1.
informational
warning
Authorization failure.
EGP Peer down: %1.
warning
12
Storage Management Appliance Software Event Code Definitions Application Notes
HP StorageWorks SAN and Brocade Switch Event Codes
HP StorageWorks SAN and Brocade Switch Event Codes
The following events are generated by HP StorageWorks SAN switches and Brocade switches
and are recorded in the Storage Management Appliance Event Log. Many of these event types
have several possible states and each state has an appropriate severity code.
The Storage Management Appliance supports the StorageWorks SAN and Brocade MIB
version 4.0.
Table 6: StorageWorks SAN and Brocade Switch Event Codes
Event
ID
Event
Code
Possible States Severity
Description
105
88020069
unknown
online
offline
testing
faulty
0
2
5
2
7
Port Index %2 changed state to %1%n
SSN: %3%n
GroupName: %3%n
GroupType: %5%n
Group MemPosition: %6%n
A swFCPortScn(3) is generated whenever
an FC_Port changes its operational state.
For instance, the FC_Port goes from on-line
to offline. The VarBind in the Trap Data Unit
shall contain the corresponding instance of
the FC_Port's operational status and index.
101
103
88020065
88020067
ok
faulty
unknown
2
5
0
Switch is faulty.
Faulty reason: %1%n
SSN: %2%n
GroupName: %3%n
GroupType: %4%n
Group MemPosition: %5%n
A swFault(1) is generated whenever the
diagnostics detects a fault with the switch.
unknown
faulty
below minimum
normal
above maximum
absent
0
5
7
2
5
2
%5 is currently in state %1%n
SSN: %7%n
GroupName: %3%n
GroupType: %8%n
Group MemPosition: %9%n
A swSensorScn(2) is generated whenever
an environment sensor changes its
operational state. For instance, a fan stops
working. The VarBind in the Trap Data Unit
shall contain the corresponding instance of
the sensor status, sensor index, sensor type,
sensor value (reading) and sensor
information. Note that the sensor
information contains the type of sensor and
its number in textual format.
107
8802006B
critical
5
5
3
2
2
Event %1: %2 (severity level %3) - %5%n
SSN: %6%n
error
warning
informational
debug
GroupName: %7%n
GroupType: %8%n
GroupMemPosition: %9%n
This trap is generated when an event whose
level at or below swEventTrapLevel occurs.
Storage Management Appliance Software Event Code Definitions Application Notes
13
HP StorageWorks SAN and Brocade Switch Event Codes
Table 6: StorageWorks SAN and Brocade Switch Event Codes (Continued)
Event
ID
Event
Code
Possible States Severity
Description
109
8802006D
informational
normal
faulty
2
2
7
Fabric Watch has generated an event.%n
Threshold %3 in Class/Area %1 at index
%2 has generated event %7 with %5 on
%6.%n
This event is %8%n
SSN: %9%n
GroupName: %10%n
GroupType: %11%n
GroupMemPosition: %12%n
Trap sent by Fabric Watch to notify of an
event.
111
8802006F
informational
2
A track change has generated a trap.
%1%n.
SSN: %2
GroupName: %3
GroupType: %4
GroupMemPosition: %5%n
Trap sent for tracking login/logout/config
changes.
100
113
115
117
119
121
123
88020064
88020071
88020073
88020075
88020077
88020079
8802007B
informational
informational
informational
warning
2
2
2
3
2
3
3
An unknown trap event was received.
Cold Start.
Warm Start.
Link Down: %1.
informational
informational
informational
Link Up: %1.
Authorization failure.
EGP Peer down: %1.
14
Storage Management Appliance Software Event Code Definitions Application Notes
HSG Element Manager Event Codes
HSG Element Manager Event Codes
The HSG Element Manager is an application provided with the Storage Management
Appliance and used to configure and monitor HSG80/60 storage elements. The HSG Element
Manager generates events that help a user understand the status of both the manager
application and the storage elements. The system records these events in the Storage
Management Appliance Event Log.
Table 7: HSG Element Manager Event Codes
Event ID
6001
6002
6003
6004
6005
6006
6007
6008
6009
6010
6011
6012
6013
6014
6015
6016
6017
6018
6019
6020
6021
6022
6023
6024
6025
6026
6027
6028
6029
6030
6031
6032
6033
6034
6035
Event Code
88011771
88011772
88011773
88011774
88011775
88011776
88011777
88011778
88011779
8801177A
8801177B
8801177C
8801177D
8801177E
8801177F
88011780
88011781
88011782
88011783
88011784
88011785
88011786
88011787
88011788
88011789
8801178A
8801178B
8801178C
8801178D
8801178E
8801178F
88011790
88011791
88011792
88011793
Severity
2
Description
HSGSubsystem object created.
2
2
5
2
5
2
2
3
2
5
7
3
4
3
2
3
5
2
5
5
4
4
4
4
4
4
7
7
7
7
7
7
7
7
Sense Data found.
%1 state changed to online
%1 state changed to offline
%1 container state changed to good
%1 container state changed to failed
%1 container state changed to Reconstructing
%1 container state changed to Initializing
%1 container state changed to Reduced
%1 state changed to good. %2
%1 state changed to failed. %2
No controllers found
New controller %1 found
Other controller %1 unreachable
Other controller %1 reachable
Controller %1 Cache Battery state changed to good
Controller %1 Cache Battery state changed to low
Controller %1 Cache Battery state changed to bad
Controller %1 Cache state changed to good
Controller %1 Cache state changed to bad
Controller %1 Cache state changed to invalid
Failed to refresh HSGSubsystem
Failed to refresh Virtual Disks
Failed to refresh Storage Sets
Failed to refresh Devices
Failed to refresh Host Connections
Failed to rescan HSGSubsystem
Striped Mirror set modification. Members do not match
Too few mirrorset members for striped mirror set
Mirrorset already a member
STL Exception generated. %1
Unknown system Exception generated. %1
HSG Exception generated. %1
Invalid Controller Pointer
Invalid Container Pointer. %1
Storage Management Appliance Software Event Code Definitions Application Notes
15
HSG Element Manager Event Codes
Table 7: HSG Element Manager Event Codes (Continued)
Event ID
6036
6037
6038
6039
6040
6041
6042
6043
6044
6045
6046
6047
6048
6049
6050
6051
6052
6053
6054
6055
6056
6057
6058
6059
6060
6061
6062
6063
6064
6065
6066
6067
6068
6069
6070
6071
6072
6073
6074
6075
6076
Event Code
88011794
88011795
88011796
88011797
88011798
88011799
8801179A
8801179B
8801179C
8801179D
8801179E
8801179F
880117A0
880117A1
880117A2
880117A3
880117A4
880117A5
880117A6
880117A7
880117A8
880117A9
880117AA
880117AB
880117AC
880117AD
880117AE
880117AF
880117B0
880117B1
880117B2
880117B3
880117B4
880117B5
880117B6
880117B7
880117B8
880117B9
880117BA
880117BB
880117BC
Severity
3
Description
Device not found. %1
%1 not found
3
3
3
4
2
2
2
2
3
2
3
7
4
4
4
4
4
4
4
4
4
2
2
2
2
2
2
2
4
4
4
2
4
7
4
4
4
6
2
6
Storage Set not found
Host Connection not found
Test Unit Ready failed
Virtual Disk %1 deleted
Virtual Disk %1 created
Device %1 added
Device %1 deleted
Host Connection %1 went offline
Host Connection %1 went online
Invalid parameter was found in request. %1
Invalid Storage Set type found. %1
Attempt to create virtual disk failed. %1
Attempt to modify virtual disk failed. %1
Attempt to delete virtual disk failed. %1
Attempt to modify device failed. %1
Attempt to modify Controller failed. %1
Attempt to modify Host Connection failed. %1
Attempt to delete Host Connection failed. %1
Attempt to rename Host Connection failed. %1
Snapshot: %1 not created.
Snapshot: %1 created.
Virtual Disk modified. %1
%1 modified
Controller modified. %1
Host Connection %1 modified
Host connection %1 has been renamed to %2
Host Connection %1 deleted
Attempt to rescan storage failed. %1
Attempt to Delete Storage Set failed. %1
Attempt to Delete Device failed. %1
Virtual disk: %1, %2 member removed.
Attempt to remove a member from a Virtual Disk failed. %1
Invalid Device Pointer. %1
Attempt to remove Failed Set member failed. %1
Attempt to add member to Spare Set failed. %1
Attempt to remove member from Spare Set failed. %1
EMU state now invalid. %1
EMU state now valid. %1
Power supply has gone bad. %1
16
Storage Management Appliance Software Event Code Definitions Application Notes
HSG Element Manager Event Codes
Table 7: HSG Element Manager Event Codes (Continued)
Event ID
6077
6078
6079
6080
6081
6082
6083
6084
6085
6086
6087
6088
6089
6090
6091
6092
6093
6094
6095
6096
6097
6098
6099
6100
6101
6102
6103
6104
6105
6106
6107
6108
6109
6110
6111
6112
6113
6114
6115
6116
6117
Event Code
880117BD
880117BE
880117BF
880117C0
880117C1
880117C2
880117C3
880117C4
880117C5
880117C6
880117C7
880117C8
880117C9
880117CA
880117CB
880117CC
880117CD
880117CE
880117CF
880117D0
880117D1
880117D2
880117D3
880117D4
880117D5
880117D6
880117D7
880117D8
880117D9
880117DA
880117DB
880117DC
880117DD
880117DE
880117DF
880117E0
880117E1
880117E2
880117E3
880117E4
880117E5
Severity
2
Description
Power supply is now good. %1
6
2
6
2
6
2
2
6
7
2
6
2
2
2
6
2
6
2
6
2
3
2
6
2
4
2
4
2
4
2
3
3
4
4
2
2
4
2
2
4
Fan has gone bad. %1
Fan is now good. %1
High Temperature detected. %1
Temperature is within optimal range. %1
Airflow is bad. %1
Airflow is now good. %1
EMU is present
EMU is no longer present
Cabinet %1 went offline
Cabinet %1 went online
Master cabinet has no controller installed. %1
Master cabinet has controller installed. %1
Controller present but present in slave cabinet. %1
Master cabinet has controller installed. %1
UPS has gone bad. %1
UPS is now good. %1
Shelf is bad. %1
Shelf is good. %1
Voltage has gone bad. %1
Voltage is now good. %1
Other controller failed
Other controller now good
Communication with subsystem has gone down. %1
Regained communication to subsystem
Attempt to create Remote Copy Set failed. %1
Remote copy set: %1 created.
Attempt to Delete Remote Copy Set failed. %1
RCS: %1 deleted.
Attempt to modify Remote Copy Set failed. %1
%1 RCS has been modified.
No Modifications were made. %1
Attempt to set failsafe on Remote Copy Set failed. %1
Attempt to Delete Association failed. %1
Attempt to create Association failed. %1
Association: %1 created.
Association: %1 not deleted.
Attempt to modify Association failed. %1
%1 Association has been modified.
Name is in use
%1 unable to add to spare set
Storage Management Appliance Software Event Code Definitions Application Notes
17
HSG Element Manager Event Codes
Table 7: HSG Element Manager Event Codes (Continued)
Event ID
6118
6119
6120
6121
6122
6123
6124
6125
6126
6127
6128
6129
6130
6131
6132
6133
6134
6135
6136
6137
6138
6139
6140
6141
6142
6143
6144
6145
6146
6147
6148
6149
6150
6151
6152
6153
6154
6155
6156
6157
6158
Event Code
880117E6
880117E7
880117E8
880117E9
880117EA
880117EB
880117EC
880117ED
880117EE
880117EF
880117F0
880117F1
880117F2
880117F3
880117F4
880117F5
880117F6
880117F7
880117F8
880117F9
880117FA
880117FB
880117FC
880117FD
880117FE
880117FF
88011800
88011801
88011802
88011803
88011804
88011805
88011806
88011807
88011808
88011809
8801180A
8801180B
8801180C
8801180D
8801180E
Severity
2
Description
Item is already used
2
2
2
4
2
2
4
2
4
7
4
3
2
2
2
4
4
2
6
4
2
2
2
4
2
2
4
2
2
2
2
2
2
2
2
2
2
2
2
2
Device %1 added to Spare Set
Device %1 removed from Spare Set
Device removed from Failed Set
Attempt to expand Virtual Disk failed. %1
Virtual Disk expanded
%1 Virtual Disk not expandable
Incomplete Concatset modify: %1
Storage Set modified
Attempt to modify Chunksize failed
HSGSubsystem Assertion
Codeload failed. %1
Codeload Error. %1
Top Controller is rebooting
Bottom Controller is rebooting
Both Controllers are rebooting
Could not locate top controller
Could not locate bottom controller
Operating state is normal. %1
Operating state is failed. %1
Operating state is impaired. %1
Top controller is done rebooting
Bottom controller is done rebooting
Both controllers are done rebooting
Reboot of controller failed. %1
SCSI command did not complete. %1
EMU modified
EMU modify failed
Unit is an Association Log Device
Unit is an RCS Initiator
Unit has been expanded
Unit has no preferred path
Unit is transportable
Unit is a Snapshot
Unit writeback cache is disabled
Unit storage container is partitioned
Incompatible storage container type
No peer to peer configuration
Unit is in Failed state
Unit has too few devices
Unit not in correct state
18
Storage Management Appliance Software Event Code Definitions Application Notes
HSG Element Manager Event Codes
Table 7: HSG Element Manager Event Codes (Continued)
Event ID
6159
6160
6161
6162
6163
6164
6165
6166
6167
6168
6169
6170
6171
6172
6173
6174
6175
6176
6177
6178
6179
6180
Event Code
8801180F
88011810
88011811
88011812
88011813
88011814
88011815
88011816
88011817
88011818
88011819
8801181A
8801181B
8801181C
8801181D
8801181E
8801181F
88011820
88011821
88011822
88011823
88011824
Severity
2
Description
Unit is used by another configuration
2
2
2
2
2
2
3
3
4
3
4
2
2
4
2
7
2
2
4
2
2
Unit is a Snapshot source
Subsystem firmware does not support snapshots
Subsystem does not have peer to peer support enabled
HSGSubsystem Miscellaneous info
Mirror cache is not enabled
Controller cache size is too small
HSGSubsystem Unknown Status
Subsystem has the maximum number of snapshots
Not enough available physical disks or unused stripes
Reached maximum physical disk count
Virtual Disk is a target
Initialize container failed. %1
Initialized container successfully. %1
No available containers
Reservation mutex check failed
Container not found. %1
%1 Used by name list
Unable to disable the PPRCMode
Add VD member failed. %1
Virtual Disk: %1, added member %2 successfully
Check VirtualDisk not in REDUCE state or Replacement
policy not NONE or not available physical disks
6181
6182
88011825
88011826
2
4
Rejected because of reservation. %1
Need ACS firmware revision 8.7 for management
lockdown
6183
6184
6185
6186
6187
6188
6189
6190
6191
7001
7002
7003
7004
7005
7006
88011827
88011828
88011829
8801182A
8801182B
8801182C
8801182D
8801182E
8801182F
88011B59
88011B5A
88011B5B
88011B5C
88011B5D
88011B5E
2
2
2
2
2
2
2
2
2
6
4
4
4
4
4
Virtual disk %1 has been reserved by %2
A virtual disk has been unreserved. %1
Virtual disk reservation failure. %1
Management lock down change. %1
No available disks
Maximum number of members
Replacement policy must be NOPOLICY
Raidset must be in reduced state
Code patch %1-%2 is Succesfully loaded on %3 controller
HSGSubsystem API has lost comm to Subsystem. %1
HSGSubsystem API has returned controller error text. %1
HSGSubsystem API has received Invalid show this output
HSGAPI::getAllControllers: Invalid SHOW OTHER output
Invalid SHOW UNIT output %1
HSGSubsystem API has received Invalid show storage
output. %1
Storage Management Appliance Software Event Code Definitions Application Notes
19
HSG Element Manager Event Codes
Table 7: HSG Element Manager Event Codes (Continued)
Event ID
7007
Event Code
88011B5F
Severity
4
Description
Invalid SHOW DEV FULL output
7008
88011B60
4
3
3
3
HSGSubsystem API has received Invalid show connection
output. %1
7009
7010
7011
88011B61
88011B62
88011B63
HSGSubsystem API received modification request but no
changes were found. %1
HSGSubsystem API received delete request but no changes
were found. %1
HSGSubsystem API invalid CLI syntax or incomplete CLI
command error (Last Status). %1
7012
7013
7014
7015
7016
88011B64
88011B65
88011B66
88011B67
88011B68
2
2
2
2
4
HSGSubsystem API has returned controller warning text
HSGSubsystem API This controller rebooting
HSGSubsystem API Other controller rebooting
HSGSubsystem API Both controllers rebooting
HSGAPI::getAllAssociations: Invalid SHOW AllAssociations
output %1
7017
88011B69
4
HSGSubsystem API has received Invalid show Remote Copy.
%1
7018
7019
7020
7021
7022
8204
88011B6A
88011B6B
88011B6C
88011B6D
88011B6E
8801200C
4
4
3
3
3
7
HSGSubsystem API Setting Host connection failure
HSGAPI::getAutospare, Invalid SHOW FAILEDSET output
Comm path switched. %1
Unable to switch comm path. %1
Last Status
A spurious interrupt was detected during the execution of a
Subsystem Built-In Self Test
8205
8206
8801200D
8801200E
7
7
An unrecoverable error was detected during execution of
the HOST PORT Subsystem Test. The system will not be able
to communicate with the host.
An unrecoverable error was detected during execution of
the UART/DUART Subsystem Test. This will cause the
console to be unusable. This will cause failover
communications to fail.
8207
8301
8302
8801200F
8801206D
8801206E
7
7
7
An unrecoverable error was detected during execution of
the FX Subsystem Test.
An unrecoverable error was detected during execution of
the PCI9060ES Test.
An unrecoverable error was detected during execution of
the Device Port Subsystem Built-In Self Test. One or more of
the device ports on the controller module has failed;
some/all of the attached storage is no longer accessible via
this controller.
8303
8304
8305
8306
8307
8308
8309
8801206F
88012070
88012071
88012072
88012073
88012074
88012075
7
2
2
6
2
3
2
Deletion of component failed.
A component location has been updated.
A component name has been updated.
HSG not communicating.
HSG is communicating.
Log approaching max size, prior entries removed.
New HSG found.
20
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
HSV Element Manager Event Codes
The HSV Element Manager is an application provided with the Storage Management
Appliance that is used to configure and monitor HSV110 Array Controllers. The HSV
Element Manager generates controller events and management agent events that help users
understand the status of both the manager application and the storage elements.
The Storage Management Appliance supports the HSV MIB version 2.0.
Controller Events
Table 8 shows events generated by the HSV Controller, which are logged in the Storage
Management Appliance Event Log. The Software Component ID (SWC ID) and Event
Number (Evt. No.) codes can be used to correlate events recorded in the Controller Event Log
of the HSV Element Manager with the events logged in the Storage Management Appliance
Event Log.
Table 8: HSV Element Manager Event Codes: Controller Events
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
100
88030064
3
0
0
Storage Cell: %1 Event Code: %2 Description: recognized Controller event
generated.
256
88030100
2
1
0
Storage Cell: %1 Event Code: %2 Description: During Executive Services
initialization the system time value was set to the value contained in the time field.
The action field contains one of the following codes which describes the condition
that caused the time value to be: 0 = TOY clock unavailable; time reset to default
date and time. 1 = TOY clock time value was less than or equal to the last known
time value previously stored in nonvolatile memory; time reset to default date and
time. 2 = EDC was bad for last known time value previously stored in nonvolatile
memory; time reset to default date and time. 3 = TOY clock not running; time
reset to default date and time. 4 = TOY clock time value believed to be accurate;
time set to TOY clock time value.
257
88030101
2
1
1
Storage Cell: %1 Event Code: %2 Description: The system time value was set to
the value contained in the time field by a call to the EXEC$SET_TIME service. As
part of setting the time in a dual HSV110 controller configuration, the times are
synchronized. The action field contains one of the following codes which
describes the action taken: 0 = The time was set to the time value on this HSV110
controller. 1 = The master HSV110 controller requested the slave HSV110
controller to set it’s time to the time value. 2 = The slave HSV110 controller set the
local time to the time value. 3 = The HSV110 controller’s TOY clock was set to the
time value.
768
769
88030300
88030301
2
6
3
3
0
1
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the node_name field has failed in communicating with the Cabinet (Rack) Bus
Interface Controller.
Storage Cell: %1 Event Code: %2 Description: The physical disk drive identified
by the device field has been rendered inoperable. If the flags.quorum_disk flag is
nonzero, the physical disk drive is the Storage System Quorum disk identified in
the quorum_sequence field. If the flags.inq_state flag is nonzero, the content of
the inq_data and capacity fields is valid. If the rss_flags.member_abnormal flag
is nonzero, the content of the member_state field is valid. The rack_num field will
not be valid until a future release.
770
88030302
3
3
2
Storage Cell: %1 Event Code: %2 Description: The physical disk drive identified
in the node_name field will not be used because the maximum number of
physical disk drives already exist in the current Storage System.
Storage Management Appliance Software Event Code Definitions Application Notes
21
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
771
88030303
2
3
3
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller has
begun booting.
772
88030304
2
3
4
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller, identified
in the node_name field, has finished the process of bringing the Storage System,
identified in the cell_tag fields, online.
773
774
88030305
88030306
2
2
3
3
5
6
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the node_name field has been joined into the Storage System.
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the node_name field has been ousted from the Storage System, identified in
the cell_tag fields
775
88030307
88030308
88030400
2
2
6
3
3
4
7
8
0
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the node_name field is now the Storage System master, identified in the
cell_tag fields, master
776
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the node_name field has been brought into the Storage System, identified in
the cell_tag fields.
1024
Storage Cell: %1 Event Code: %2 Description: HSV110 controller operation was
terminated due to an unrecoverable event detected by either software or
hardware or due to an action initiated via the Storage System Management
Interface.
1025
1026
88030401
88030402
6
6
4
4
1
2
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the lter.terminating_ctrlr field sent a last gasp message prior to terminating
operation.
Storage Cell: %1 Event Code: %2 Description: A machine check occurred while
a termination event was being processed. The post-termination operation being
performed at the time the event occurred can be derived from the
lter.reuea_index field.
Note: The lteihd and lter fields may not describe the event that caused the
HSV110 controller to terminate operation depending on how far termination
processing got before the machine check occurred.
22
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
1027
88030403
6
4
3
Storage Cell: %1 Event Code: %2 Description: An unexpected event occurred
while a termination event was being processed. The value contained in the
uei.type field describes the event as follows: 0 = Unrecognized Unexpected Event
code. 1 = Power failure before initialization could complete. 2 = Recursive
termination before initialization could complete. 3 = Terminated during the first
part post-termination preparation. 4 = Terminated during the load of the G3
Glue registers. 5 = Terminated during the second part post-termination
preparation. 6 = Terminated during event report block load. 7 = Terminated
during initialization of all hardware components and software data structures in
preparation for restart. 8 = Terminated during execution of an unrecognized
post-termination operation (premature). 9 = Power failure during execution of a
post-termination operation. A = No good entries found in Termination Event
Array. B = The EDC of one or more Termination Event Array entries is bad. C =
Terminatio n Event Array entry control block revision is different. D = Termination
Event Array entry information block revision is different. E = Termination Event
Array entry up time value is greater than the system’s up time value. F =
Termination Event Array entry up time value is less than the previous entry’s up
time value. 10= Termination Event Array entry sequence number value is less
than the previous entry’s sequence number value. 11= Detected an unrecognized
dump/restart control code. 12= Failed to terminate the entity dump loop. 13=
Unexpected dump entity size. 14= Unexpected Event Log Packet processing stage
code. 15= Number of Termination Parameters supplied not equal to maximum
allowed as required. The post-termination operation being performed at the time
the unexpected event occurred is contained in the uei.pto field.
Note: The lteihd and lter fields may not describe the event that caused the
HSV110 controller to terminate operation depending on how far t ermination
processing got before the unexpected event occurred.
1028
88030404
2
4
4
Storage Cell: %1 Event Code: %2 Description: The Storage System Event Log
validation completed successfully. The content of the cinfo.scelcbi.status field, the
cinfo.scelcbi structure, and the minfo.scelmi structure show the validated state of
the Storage System Event Log. The meaning of the status value contained in the
cinfo.scelcbi.status field is as follows: 0 = No problems found.
Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi
structure is undefined.
Storage Management Appliance Software Event Code Definitions Application Notes
23
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
1029
88030405
2
4
5
Storage Cell: %1 Event Code: %2 Description: The Storage System Event Log
validation failed. The content of the cinfo.scelcbi.status field, the cinfo.scelcbi
structure, and the minfo.scelmi structure show the state of the Storage System
Event Log at the time of the failure. The content and state of the Storage System
Event Log have been initialized to their initial operational settings. The meaning
of the status value contained in the cinfo.scelcbi.status field is as follows: 1 =
Cookie value is not as expected. 2 = Event data overflows the buffer. 3 = Event
data size is not a multiple of 4 bytes, is less than the minimum, or is greater than
the maximum. 4 = Event Information Packet type is greater than the maximum. 5
= Event information size is not a multiple of 4 bytes, is less than the minimum, is
greater than the maximum, doesn’t match the Event Information Packet type size,
or when combined with the entry header size doesn’t equal the entry size. 6 =
Event code is zero. 7 = Event is out of sequence. 8 = Dead space area at the end
of a partially packed buffer contains a nonzero value. 9 = An event data block
containing a nonzero value was found after end of event data was detected. A =
Sequence number reset flag not set as expected. B = The event log contains no
entries. C = Event data block read failed during maintenance verification. D =
Event data block read failed during maintenance completion. E = Event data
block erase failed during maintenance completion. F = Control block read failed
during maintenance verification.
Note: The content of the ainfo fields, cinfo.sctelcbi structure, and minfo.sctelmi
structure is undefined.
1030
1031
1032
88030406
88030407
88030408
6
6
2
4
4
4
6
7
8
Storage Cell: %1 Event Code: %2 Description: Event reports were lost due to an
insufficient supply of Event Log Packets on the HSV110 controller that is the
Storage System Master. The ainfo.events_not_reported field shows the number of
event reports lost.
Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field
cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.
Storage Cell: %1 Event Code: %2 Description: Event reports were lost due to an
insufficient supply of Event Log Packets on the HSV110 controller that is not the
Storage System Master. The ainfo.events_not_reported field shows the number of
event reports lost.
Note: The content of the ainfo.quiesce_type field, ainfo.remote_event field
cinfo.sctelcbi structure, and minfo.sctelmi structure is undefined.
Storage Cell: %1 Event Code: %2 Description: The Storage System Termination
Event Log has become inaccessible. The content of the cinfo.sctelcbi.status field,
the cinfo.sctelcbi structure, and the minfo.sctelmi structure show the current state
of the Storage System Termination Event Log. The meaning of the status value
contained in the cinfo.sctelcbi.status field is as follows: F = Control block read
failed during maintenance verification. 10= Control block read failed during
maintenance verification. 11= Event data block write failed during maintenance
update. 12= Control block write failed during maintenance completion. 13=
Storage System Termination Event Log related send was unsuccessful or the
master found that the Storage System Termination Event Log is inaccessible. 16=
Event data block read failed during retrieval request.
Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi
structure is undefined.
24
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
1033
88030409
2
4
9
Storage Cell: %1 Event Code: %2 Description: The Storage System Termination
Event Log validation completed successfully. The content of the
cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi
structure show the validated state of the Storage System Termination Event Log.
The meaning of the status value contained in the cinfo.sctelcbi.status field is as
follows: 0 = No problems found.
Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi
structure is undefined.
1034
8803040a
2
4
a
Storage Cell: %1 Event Code: %2 Description: The Storage System Termination
Event Log validation failed. The content of the cinfo.sctelcbi.status field, the
cinfo.sctelcbi structure, and the minfo.sctelmi structure show the state of the
Storage System Termination Event Log at the time of the failure. The meaning of
the status value contained in the cinfo.sctelcbi.status field is as follows: F =
Control block read failed during maintenance verification. 10= Control block
read failed during maintenance verification. 11= Event data block write failed
during maintenance update. 12= Control block write failed during maintenance
completion. 13= Storage System Termination Event Log related send was
unsuccessful or the master found that the Storage System Termination Event Log is
inaccessible. 16= Event data block read failed during retrieval request.
Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi
structure is undefined.
1035
8803040b
2
4
b
Storage Cell: %1 Event Code: %2 Description: The Storage System Termination
Event Log has been updated with the termination event information obtained
from the HSV110 controller that is not the Storage System Master. The content of
the cinfo.sctelcbi.status field, the cinfo.sctelcbi structure, and the minfo.sctelmi
structure show the updated state of the Storage System Termination Event Log.
The meaning of the status value contained in the cinfo.sctelcbi.status field is as
follows: 0 = No problems found.
Note: The content of the ainfo fields, cinfo.scelcbi structure, and minfo.scelmi
structure is undefined.
1036
1037
8803040c
8803040d
6
2
4
4
c
Storage Cell: %1 Event Code: %2 Description: The Fault Manager on the
Storage System Master received an invalid Event Information Packet from the
remote Fault Manager. The header information from the invalid Event Information
packet is contained in the ainfo.remote_event field.
Note: The content of the ainfo.quiesce_type field, ainfo.events_not_reported field,
cinfo.scelcbi structure, cinfo.sctelcbi structure, minfo.scelmi structure, and
minfo.sctelmi structure is undefined.
d
Storage Cell: %1 Event Code: %2 Description: The Fault Manager operation
was made quiescent. If the ainfo.quiesce_type field is equal to 0, the operation
was performed on both HSV110 controllers. If the ainfo.quiesce_type field is
equal to 1, the operation was performed only on the HSV110 controller that is
not the Storage System Master.
Note: The content of the ainfo.events_not_reported field, cinfo.scelcbi structure,
cinfo.sctelcbi structure, minfo.scelmi structure, and minfo.sctelmi structure is
undefined.
1038
8803040e
6
4
e
Storage Cell: %1 Event Code: %2 Description: An HSV110 controller sent a last
gasp message prior to terminating operation with an indication that the HSV110
controller identified in the lter.terminating_ctrlr field should also terminate
operation.
Storage Management Appliance Software Event Code Definitions Application Notes
25
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
1536
88030600
6
6
0
Storage Cell: %1 Event Code: %2 Description: A physical disk drive has
reported that it has exceeded its failure prediction threshold. The identity of the
physical disk drive is contained in the device field. The Fibre Channel port used
to communicate with the physical disk drive is contained in the cerp_id field. The
HSV110 controller internal Fibre Channel port number used to communicate with
the physical disk drive is contained in the port field. The arbitrated loop physical
address of the physical disk drive is contained in the al_pa field. If the bay field
contains a value other than zero, the location of the physical disk drive is
contained in the rack_num, dencl_num, and bay fields. If the bay field contains
a zero, the location of the physical disk drive is unknown and the content of the
rack_num and dencl_num fields is undefined. The rack_num field will not be
valid until a future release. The Fibre Channel Exchange Descriptor class is
contained in the fed_class field. The command issued to the physical disk drive is
contained in t he cmd field. The sense data obtained from the physical disk drive
as a result of the failure prediction threshold exceeded error is contained in the
error field.
1537
88030601
3
6
1
Storage Cell: %1 Event Code: %2 Description: A Fibre Channel port on the
HSV110 controller has failed to respond. The identity of the affected Fibre
Channel port is contained in the cerp_id field. The HSV110 controller internal
Fibre Channel port number of the affected Fibre Channel port is contained in the
port field. The peb array contains the port event block information. The
peq_frz_prod_index field contains the index to the port event block in use when
the Tachyon chip entered the frozen state. The peq_prod_index field contains the
index to the next port event block. The peq_cons_index field contains the index
to the next port event block to be acted upon. The failure_cause field contains the
internal routing.
1538
88030602
2
6
2
Storage Cell: %1 Event Code: %2 Description: A physical disk drive has
reported a check condition error. The identity of the physical disk drive is
contained in the device field. The Fibre Channel port used to communicate with
the physical disk drive is contained in the cerp_id field. The HSV110 controller
internal Fibre Channel port number used to communicate with the physical disk
drive is contained in the port field. The arbitrated loop physical address of the
physical disk drive is contained in the al_pa field. If the bay field contains a
value other than zero, the location of the physical disk drive is contained in the
rack_num, dencl_num, and bay fields. If the bay field contains a zero, the
location of the physical disk drive is unknown and the content of the rack_num
and dencl_num fields is undefined. The rack_num field will not be valid until a
future release. The Fibre Channel Exchange Descriptor class is contained in the
fed_class field. The command issued to the physical disk drive is contained in the
cmd field. The sense data obt ained from the physical disk drive as a result of the
check condition error is contained in the error field.
26
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
1539
1540
1541
88030603
88030604
88030605
3
6
3
4
5
Storage Cell: %1 Event Code: %2 Description: A frame sent to a physical disk
drive or another HSV110 controller via the mirror port or a Drive Enclosure
Environmental Monitoring Unit has timed out. The identity of the intended
recipient is contained in the device field. The Fibre Channel port over which the
frame was sent is identified in the cerp_id field. The HSV110 controller internal
Fibre Channel port number over which the frame was sent is contained in the
port field. The arbitrated loop physical address of the intended recipient is
contained in the al_pa field. If the bay field contains a value other than zero, the
intended recipient was the physical disk drive located as indicated by the content
of the rack_num, dencl_num, and bay fields. If the bay field contains a zero, the
location of the intended recipient is unknown and the content of the rack_num
and dencl_num fields is undefined. The rack_num field will not be valid until a
future release. The number of timeouts detected is contained in the num_times
field.
3
6
Storage Cell: %1 Event Code: %2 Description: Work was unexpectedly sent to
this HSV110 controller by a physical disk drive or another HSV110 controller.
This HSV110 controller did not originate the work. The identity of the sender is
contained in the device field. The Fibre Channel port over which the unexpected
work was received is identified in the cerp_id field. The HSV110 controller
internal Fibre Channel port number over which the unexpected work was
received is contained in the port field. The arbitrated loop physical address of
the sender is contained in the al_pa field. If the bay field contains a value other
than zero, the sender was the physical disk drive located as indicated by the
content of the rack_num, dencl_num, and bay fields. If the bay field contains a
zero, the location of the sender is unknown and the content of the rack_num and
dencl_num fields is undefined. The rack_num field will not be valid until a future
release. The hdr_cdb field contains the command descriptor block and Fibre
Channel header information associated with the unexpected work.
3
6
Storage Cell: %1 Event Code: %2 Description: Work has been sent to a physical
disk drive or another HSV110 controller via the mirror port but it did not
respond. The identity of the intended target is contained in the device field. The
Fibre Channel port over which the work was sent is identified in the cerp_id field.
The HSV110 controller internal Fibre Channel port over which the work was sent
is contained in the port field. The arbitrated loop physical address of the
intended target is contained in the al_pa field. If the bay field contains a value
other than zero, the intended target was the physical disk drive located as
indicated by the content of the rack_num, dencl_num, and bay fields. If the bay
field contains a zero, the location of the intended target is unknown and the
content of the rack_num and dencl_num fields is undefined. The rack_num field
will not be valid until a future release. The Fibre Channel Exchange Descriptor
class is contained in the fed_class field. The command issued to the intended
target is contained in the c md field. Note that in this case the content of the
error field is undefined.
Storage Management Appliance Software Event Code Definitions Application Notes
27
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
1543
88030607
3
6
7
Storage Cell: %1 Event Code: %2 Description: A Target Discovery Service
Descriptor frame sent to a physical disk drive has timed out. The identity of the
physical disk drive is contained in the device field. The Fibre Channel port used
to communicate with the physical disk drive is contained in the cerp_id field. The
HSV110 controller internal Fibre Channel port number used to communicate with
the physical disk drive is contained in the port field. The arbitrated loop physical
address of the physical disk drive is contained in the al_pa field. If the bay field
contains a value other than zero, the location of the physical disk drive is
contained in the rack_num, dencl_num, and bay fields. If the bay field contains
a zero, the location of the physical disk drive is unknown and the content of the
rack_num and dencl_num fields is undefined. The rack_num field will not be
valid until a future release. The Fibre Channel Exchange Descriptor class is
contained in the fed_class field. The command issued to the physical disk drive is
contained in th e cmd field. Note that in this case the content of the error field is
undefined.
1544
88030608
2
6
8
Storage Cell: %1 Event Code: %2 Description: An excessive number of link
errors were detected on a HSV110 controller’s Fibre Channel port. The identity
of the affected Fibre Channel port is contained in the cerp_id field. The HSV110
controller internal Fibre Channel port number of the affected Fibre Channel port
is contained in the port field. This is an informational event triggered by the
occurrence of an excessive number of Tachyon chip link status errors detected
within a particular link status error type. The number of occurrences of each link
status error type is contained in a separate type-specific field (e.g.,
loss_of_signal, bad_rx_char, etc.). The HSV110 controller checks each of its
Fibre Channel port’s for excessive link status errors periodicaly.
1545
88030609
6
6
9
Storage Cell: %1 Event Code: %2 Description: A physical disk drive has
reported numerous failure prediction threshold exceeded errors. The identity of
the physical disk drive is contained in the device field. The Fibre Channel port
used to communicate with the physical disk drive is contained in the cerp_id field.
The HSV110 controller internal Fibre Channel port number used to communicate
with the physical disk drive is contained in the port field. The arbitrated loop
physical address of the physical disk drive is contained in the al_pa field. If the
bay field contains a value other than zero, the location of the physical disk drive
is contained in the rack_num, dencl_num, and bay fields. If the bay field contains
a zero, the location of the physical disk drive is unknown and the content of the
rack_num and dencl_num fields is undefined. The rack_num field will not be
valid until a future release. The Fibre Channel Exchange Descriptor class is
contained in the fed_class field. The num_times field is the number of failure
prediction threshol d exceeded errors reported by the physical disk drive in the
previous minute.
28
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
1546
8803060a
2
6
a
Storage Cell: %1 Event Code: %2 Description: A physical disk drive has
reported numerous check condition errors. The identity of the physical disk drive
is contained in the device field. The Fibre Channel port used to communicate
with the physical disk drive is contained in the cerp_id field. The HSV110
controller internal Fibre Channel port number used to communicate with the
physical disk drive is contained in the port field. The arbitrated loop physical
address of the physical disk drive is contained in the al_pa field. If the bay field
contains a value other than zero, the location of the physical disk drive is
contained in the rack_num, dencl_num, and bay fields. If the bay field contains
a zero, the location of the physical disk drive is unknown and the content of the
rack_num and dencl_num fields is undefined. The rack_num field will not be
valid until a future release. The Fibre Channel Exchange Descriptor class is
contained in the fed_class field. The num_times field is the number of check
condition errors reported by the physical disk drive in the previous minute.
1547
8803060b
3
6
b
Storage Cell: %1 Event Code: %2 Description: A non-data exchange frame sent
to a physical disk drive has timed out. The identity of the physical disk drive is
contained in the device field. The Fibre Channel port used to communicate with
the physical disk drive is contained in the cerp_id field. The HSV110 controller
internal Fibre Channel port number used to communicate with the physical disk
drive is contained in the port field. The arbitrated loop physical address of the
physical disk drive is contained in the al_pa field. If the bay field contains a
value other than zero, the location of the physical disk drive is contained in the
rack_num, dencl_num, and bay fields. If the bay field contains a zero, the
location of the physical disk drive is unknown and the content of the rack_num
and dencl_num fields is undefined. The rack_num field will not be valid until a
future release. The Fibre Channel Exchange Descriptor class is contained in the
fed_class field. The command issued to the physical disk drive is contained in the
cmd field. Note that in this case the content of the error field is undefined.
1548
1549
8803060c
8803060d
2
2
6
6
c
Storage Cell: %1 Event Code: %2 Description: A loop switch has been detected
on a Fibre Channel port. The identity of the Fibre Channel port is contained in
the cerp_id field. The HSV110 controller internal Fibre Channel port number is
contained in the port field. Note that in this case the device, al_pa, rack_num,
dencl_num, bay, fed_class and num_times fields are undefined.
d
Storage Cell: %1 Event Code: %2 Description: The location of a physical disk
drive previously reported as unknown is now known. The identity of the physical
disk drive is contained in the device field. The Fibre Channel port used to
communicate with the physical disk drive is contained in the cerp_id field. The
HSV110 controller internal Fibre Channel port number used to communicate with
the physical disk drive is contained in the port field. The arbitrated loop physical
address of the physical disk drive is contained in the al_pa field. The location of
the physical disk drive is contained in the rack_num, dencl_num, and bay fields.
The rack_num field will not be valid until a future release. Note that in this case
the content of the fed_class and num_times fields is undefined.
Storage Management Appliance Software Event Code Definitions Application Notes
29
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
1550
8803060e
6
6
e
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental
Monitoring Unit requested a code update but the code update could not be
found, so the update was not performed. The identity of the affected Drive
Enclosure Environmental Monitoring Unit is contained in the device field. The
Fibre Channel port used to communicate with the Drive Enclosure Environmental
Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal
Fibre Channel port number used to communicate with the Drive Enclosure
Environmental Monitoring Unit is contained in the port field. The location of the
Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and
dencl_num fields. The rack_num field will not be valid until a future release.
Note that in this case the content of the al_pa, bay, fed_class and num_times
field is undefined.
1551
8803060f
6
6
f
Storage Cell: %1 Event Code: %2 Description: The Drive Enclosure
Environmental Monitoring Unit is able to communicate with a physical disk drive
but this HSV110 controller is unable to communicate with that physical disk drive
on the Fibre Channel bus. The identity of the Drive Enclosure Environmental
Monitoring Unit is contained in the device field. The Fibre Channel port used to
communicate with the physical disk drive is contained in the cerp_id field. The
HSV110 controller internal Fibre Channel port number used to communicate with
the physical disk drive is contained in the port field. The location of the physical
disk drive is contained in the rack_num, dencl_num, and bay fields. The
rack_num field will not be valid until a future release. Note that in this case the
content of the al_pa, fed_class and num_times fields is undefined.
1552
88030610
6
6
10
Storage Cell: %1 Event Code: %2 Description: The Drive Enclosure
Environmental Monitoring Unit is unable to communicate with this HSV110
controller. The Drive Enclosure Environmental Monitoring Unit has either stopped
communicating with the HSV110 controller, or is not connected to the rack. If the
Drive Enclosure Environmental Monitoring Unit is not connected to the rack, then
the location of the Drive Enclosure Environmental Monitoring Unit is unknown. If
the bay field contains a value other than zero, the identity of the Drive Enclosure
Environmental Monitoring Unit is contained in the device field. If the bay field
contains a zero, the content of the device field is undefined. The Fibre Channel
port used to communicate with the Drive Enclosure Environmental Monitoring
Unit is contained in the cerp_id field. The HSV110 controller internal Fibre
Channel port number used to communicate with the Drive Enclosure
Environmental Monitoring Unit is contained in the port field. If the bay field
contains a value other than zero, the location of the Dr ive Enclosure
Environmental Monitoring Unit is contained in the rack_num and dencl_num
fields. If the bay field contains a zero, the location of the Drive Enclosure
Environmental Monitoring Unit is unknown and the content of the rack_num and
dencl_num fields is undefined. The rack_num field will not be valid until a future
release. Note that in this case the content of the al_pa, fed_class and num_times
fields is undefined.
30
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
1554
88030612
2
6
12
Storage Cell: %1 Event Code: %2 Description: The retry count for a task
assigned to a Drive Enclosure Environmental Monitoring Unit has been
exhausted. The Fibre Channel port used to communicate with the physical disk
drive is contained in the cerp_id field. The HSV110 controller internal Fibre
Channel port number used to communicate with the physical disk drive is
contained in the port field. The peb array contains the task list that was intended
to be sent to the Drive Enclosure Environmental Monitoring Unit. The
peq_frz_prod_index field contains the task that was being retried. The
peq_prod_index field contains the drive enclosure where the physical disk drive
used to communicate with the Drive Enclosure Environmental Monitoring Unit is
located. The peq_cons_index field identifies the Fibre Channel loop pair (0 =
Loop A, 1 = Loop B) used to communicate with the physical disk drive that was
used to communicate with the Drive Enclosure Environmental Monitoring Unit.
The failure_cause field contains the bay where the physical disk drive used to
communicate with the
1555
88030613
2
6
13
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental
Monitoring Unit is able to communicate with this HSV110 controller. The identity
of the Drive Enclosure Environmental Monitoring Unit is contained in the device
field. The Fibre Channel port used to communicate with the Drive Enclosure
Environmental Monitoring Unit is contained in the cerp_id field. The HSV110
controller internal Fibre Channel port number used to communicate with the
Drive Enclosure Environmental Monitoring Unit is contained in the port field. The
location of the Drive Enclosure Environmental Monitoring Unit is contained in the
rack_num and dencl_num fields. The rack_num field will not be valid until a
future release. Note that in this case the content of the bay, fed_class and
num_times fields is undefined.
1556
1557
1558
1559
88030614
88030615
88030616
88030617
6
6
6
6
6
6
6
6
14
15
16
17
Storage Cell: %1 Event Code: %2 Description: There are too many drive
enclosures. The Fibre Channel port with too many drive enclosures attached to
the HSV110 controller is contained in the cerp_id field. Note that in this case the
content of the bay, fed_class, rack_num, dencl_num and num_times fields is
undefined.
Storage Cell: %1 Event Code: %2 Description: The cable connected to the I/O
module is attached to the wrong Fibre Channel port. The Fibre Channel port
incorrectly attached to the HSV110 controller is contained in the cerp_id field.
Note that in this case the content of the bay, fed_class, rack_num, dencl_num
and num_times fields is undefined.
Storage Cell: %1 Event Code: %2 Description: A HSV110 controller does not
have an address on the enclosure address bus. The HSV110 controller location
cannot be identified. Note that in this case the content of the bay, fed_class,
rack_num, dencl_num, alpa, device, cerp_id, port, and num_times fields are
undefined.
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental
Monitoring Unit has detected a physical disk drive that was preventing proper
loop operation. The physical disk drive has been bypassed and is ready for
replacement. The location of this physical disk drive is specified by the
rack_num, bay, and dencl_num fields. The rack_num field will not be valid until
a future release. The identity of the Drive Enclosure Environmental Monitoring
Unit is contained in the device field. The UUID of the specific physical disk drive
is not identifiable. Check the fault lights of the enclosure associated with this Drive
Enclosure Environmental Monitoring Unit. Note that in this case the content of
the fed_class, alpa, and num_times fields are undefined.
Storage Management Appliance Software Event Code Definitions Application Notes
31
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
1560
88030618
2
6
18
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental
Monitoring Unit has begun updating its code. Do not power down this drive
enclosure until the code update has completed. The identity of the Drive Enclosure
Environmental Monitoring Unit is contained in the device field. The Fibre
Channel port used to communicate with the Drive Enclosure Environmental
Monitoring Unit is contained in the cerp_id field. The HSV110 controller internal
Fibre Channel port number used to communicate with the Drive Enclosure
Environmental Monitoring Unit is contained in the port field. The location of the
Drive Enclosure Environmental Monitoring Unit is contained in the rack_num and
dencl_num fields. The rack_num field will not be valid until a future release.
Note that in this case the content of the fed_class, alpa, and num_times fields are
undefined.
1561
88030619
2
6
19
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental
Monitoring Unit has completed updating its code. It is now safe to power down
this drive enclosure. The identity of the Drive Enclosure Environmental Monitoring
Unit is contained in the device field. The Fibre Channel port used to
communicate with the Drive Enclosure Environmental Monitoring Unit is
contained in the cerp_id field. The HSV110 controller internal Fibre Channel
port number used to communicate with the Drive Enclosure Environmental
Monitoring Unit is contained in the port field. The location of the Drive Enclosure
Environmental Monitoring Unit is contained in the rack_num and dencl_num
fields. The rack_num field will not be valid until a future release. Note that in this
case the content of the fed_class, alpa, and num_times fields are undefined.
1562
8803061a
6
6
1a
Storage Cell: %1 Event Code: %2 Description: A physical disk drive has
exceeded its soft error threshold. The identity of the physical disk drive is
contained in the device field. The Fibre Channel port used to communicate with
the physical disk drive is contained in the cerp_id field. The HSV110 controller
internal Fibre Channel port number used to communicate with the physical disk
drive is contained in the port field. The arbitrated loop physical address of the
physical disk drive is contained in the al_pa field. If the bay field contains a
value other than zero, the location of the physical disk drive is contained in the
rack_num, dencl_num, and bay fields. If the bay field contains a zero, the
location of the physical disk drive is unknown and the content of the rack_num
and dencl_num fields is undefined. The rack_num field will not be valid until a
future release. Note that in this case the content of the fed_class, cdb, and
sense_data fields are undefined.
1563
8803061b
2
6
1b
Storage Cell: %1 Event Code: %2 Description: A HSV110 controller now has an
address on the enclosure address bus. The HSV110 controller location has been
identified. The location of the HSV110 controller is contained in the rack_num
and dencl_num fields. The rack_num field will not be valid until a future release.
Note that in this case the content of the bay, fed_class, alpa, cerp_id, port, and
num_times fields are undefined.
32
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
1564
8803061c
3
6
1c
Storage Cell: %1 Event Code: %2 Description: A non-data exchange frame sent
to a physical disk drive has timed out. The identity of the physical disk drive is
contained in the device field. The Fibre Channel port used to communicate with
the physical disk drive is contained in the cerp_id field. The HSV110 controller
internal Fibre Channel port number used to communicate with the physical disk
drive is contained in the port field. The arbitrated loop physical address of the
physical disk drive is contained in the al_pa field. If the bay field contains a
value other than zero, the location of the physical disk drive is contained in the
rack_num, dencl_num, and bay fields. If the bay field contains a zero, the
location of the physical disk drive is unknown and the content of the rack_num
and dencl_num fields is undefined. The rack_num field will not be valid until a
future release. The Fibre Channel Exchange Descriptor class is contained in the
fed_class field. The command issued to the physical disk drive is contained in the
cmd field. Note that in this case the content of the error field is undefined.
2305
2306
2307
88030901
88030902
88030903
2
2
2
9
9
9
1
2
3
Storage Cell: %1 Event Code: %2 Description: The state of the Physical Disk
Drive identified in the handle field has transitioned to the NORMAL state. The
value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains
the old state. The state values that may be in the value.ul2 field are as follows: 2
= Degraded 3 = Failed 4 = Not present
Storage Cell: %1 Event Code: %2 Description: The state of the Volume identified
in the handle field has changed. The value.ul1 field contains the new state. The
value.ul2 field contains the old state. The state values that may be found in the
value.ul1 and value.ul2 fields are as follows: 1 = Normal 2 = Migrating 3 =
Missing 4 = Reconstructing 5 = Completing 6 = Reverting 7 = Failed
Storage Cell: %1 Event Code: %2 Description: The state of The internal Logical
Disk associated with the Virtual Disk identified in the handle field has changed.
The value.ul1 field contains the new state. The value.ul2 field contains the old
state. The state values that may be found in the value.ul1 and value.ul2 fields are
as follows: 1 = Normal 2 = Replacement delay in progress 3 = Redundancy lost,
restore in progress 4 = Redundancy lost, restore stalled 5 = Failed 6 = Creation in
progress 7 = Snapshot is inoperative due to lack of snapshot space 8 = Deletion
in progress 9 = Capacity change in progress 10 = Inoperative due to data lost
2308
2309
88030904
88030905
2
2
9
9
4
5
Storage Cell: %1 Event Code: %2 Description: The state of the HSV110
controller identified in the handle field has transitioned to the NORMAL state. The
value.ul1 field contains the new state: 1 (NORMAL). The value.ul2 field contains
the old state: 3 (FAILED).
Storage Cell: %1 Event Code: %2 Description: The state of a battery assembly
within the HSV110 controller identified in the handle field has changed. The
value.ul1 field contains the new state. The value.ul2 field contains the old state.
The state values that may be found in the value.ul1 and value.ul2 fields are as
follows: 1 = Battery System Hold-up Time is greater than 96 hours 3 = Battery
System Hold-up Time is greater than 0 and less than 96 hours 5 = Battery System
Hold-up Time is zero hours
2310
88030906
6
9
6
Storage Cell: %1 Event Code: %2 Description: The state of the Volume identified
in the handle field has transitioned to the MISSING state. The value.ul1 field
contains the new state: 3 (MISSING). The value.ul2 field contains the old state.
The state values that may be found in the value.ul2 field are as follows: 1 =
Normal 2 = Migrating 4 = Reconstructing 5 = Completing 6 = Reverting 7 =
Failed
Storage Management Appliance Software Event Code Definitions Application Notes
33
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
2311
88030907
2
9
7
Storage Cell: %1 Event Code: %2 Description: The state of the Fibre Channel
port identified in the attribute.value.str field and located on the rear panel of the
HSV110 controller identified in the handle field has transitioned to the NORMAL
state. The attribute.type field contains the value 4. The value.ul1 field contains the
new state: 1 (NORMAL). The value.ul2 field contains the old state: 2 (FAILED).
Note that the HSV110 controller’s internal identity of the affected Fibre Channel
port is contained in the secondary_id field.
2312
2313
88030908
88030909
3
2
9
9
8
9
Storage Cell: %1 Event Code: %2 Description: The Occupancy Alarm Level
threshold has been reached for the Disk Group identified in the handle field.
Storage Cell: %1 Event Code: %2 Description: The Resource Availability state of
the Volume identified in the handle field has transitioned to the SUFFICIENT state.
The value.ul1 field contains the new state: 0 (SUFFICIENT). The value.ul2 field
contains the old state: 1 (INSUFFICIENT).
2314
8803090a
2
9
a
Storage Cell: %1 Event Code: %2 Description: The Data Availability state of the
Logical Disk identified in the handle field has transitioned to the NORMAL state.
The value.ul1 field contains the new state: 0 (NORMAL). The value.ul2 field
contains the old state: 1 (DATA LOST).
2316
2317
8803090c
8803090d
2
2
9
9
c
Storage Cell: %1 Event Code: %2 Description: The Snapclone Logical Disk
identified in the handle field has completed the unsharing operation.
d
Storage Cell: %1 Event Code: %2 Description: The state of the Quorum Disk flag
for the Volume identified in the handle field has changed. The value.ul1 field
contains the new state of the Quorum Disk flag. The value.ul2 field contains the
old state of the Quorum Disk flag. The state values that may be found in the
value.ul1 and value.ul2 fields are as follows: 0 = FALSE 1 = TRUE
2318
2319
8803090e
8803090f
3
3
9
9
e
f
Storage Cell: %1 Event Code: %2 Description: The temperature trip point for a
temperature sensor located within the HSV110 controller identified in the handle
field has been reached.
Storage Cell: %1 Event Code: %2 Description: A temperature sensor located
within the HSV110 controller identified in the handle field is approaching its trip
point. The value.ul1 field contains the current temperature reading from that
sensor in Celsius. The secondary_id field contains the temperature trip point in
Celsius.
2321
88030911
2
9
11
Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘1’
blower assembly located within the HSV110 controller identified in the handle
field has transitioned from the NOT PRESENT to PRESENT state indicating that
the blower has been reinstalled. The secondary_id field contains the ‘1’ blower
assembly internal identifier value: 1. The value.ul1 field contains the new state of
the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of
the Blower Present flag: 0 (NOT PRESENT).
2322
2323
88030912
88030913
6
2
9
9
12
13
Storage Cell: %1 Event Code: %2 Description: The ‘1’ blower located within the
HSV110 controller identified in the handle field is running slower than the lowest
acceptable speed. The secondary_id field contains the ‘1’ blower assembly
internal identifier value: 1. The value.ul1 field contains the current speed of the
‘1’ blower. The value.ul2 field contains the lowest acceptable speed for the ‘1’
blower.
Storage Cell: %1 Event Code: %2 Description: One of the voltage sensors
located within the HSV110 controller identified in the handle field has reported a
voltage that is out of range. The value.ul1 field contains the out of range voltage
value. The secondary_id field contains the specific voltage threshold value (i.e.,
12V, 5V, 3.3V, 2.5V or 2V). Note that the voltages are expressed in
millivolts--e.g.,12.5V is expressed as 12500.
34
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
2324
88030914
6
9
14
Storage Cell: %1 Event Code: %2 Description: The state of the Volume identified
in the handle field has transitioned to the FAILED state. The value.ul1 field
contains the new state: 7 (FAILED). The value.ul2 field contains the old state. The
state values that may be found in the value.ul2 fields are as follows: 1 = Normal
2 = Migrating 3 = Missing 4 = Reconstructing 5 = Completing 6 = Reverting
2325
2327
88030915
88030917
6
6
9
9
15
17
Storage Cell: %1 Event Code: %2 Description: The state of the HSV110
controller identified in the handle field has transitioned to the FAILED state. The
value.ul1 field contains the new state: 3 (FAILED). The value.ul2 field contains the
old state: 1 (NORMAL).
Storage Cell: %1 Event Code: %2 Description: The Battery Present flag for
battery assembly ‘1’ located within the HSV110 controller identified in the
handle field has changed from PRESENT to NOT PRESENT indicating that the
battery assembly was removed. The secondary_id field contains the battery
assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state
of the Battery Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old
state of the Battery Present flag: 1 (PRESENT).
2328
2329
88030918
88030919
2
2
9
9
18
19
Storage Cell: %1 Event Code: %2 Description: The Battery In Use flag for battery
assembly ‘1’ located within the HSV110 controller identified in the handle field
has transitioned from the NOT IN USE to IN USE state indicating that the battery
assembly is functioning properly. The secondary_id field contains the battery
assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state
of the Battery In Use flag: 1 (IN USE). The value.ul2 field contains the old state of
the Battery In Use flag: 0 (NOT IN USE).
Storage Cell: %1 Event Code: %2 Description: One of the voltage sensors
located within the HSV110 controller identified in the handle field has reported a
voltage that indicates that a voltage that was previously out of range has returned
to the normal range. The value.ul1 field contains the normal range voltage
value. The secondary_id field contains the voltage threshold value (i.e., 12V, 5V,
3.3V, 2.5V or 2V). Note that the voltages are expressed in thousands--e.g.,
12.5V is expressed as 12500.
2330
2331
8803091a
8803091b
3
2
9
9
1a
1b
Storage Cell: %1 Event Code: %2 Description: The battery assembly voltage
regulator located within the HSV110 controller identified in the handle field is
offline.
Storage Cell: %1 Event Code: %2 Description: The state of the Disk Group
identified in the handle field has transitioned to the NORMAL state. The value.ul1
field contains the new Disk Group state: 1 (NORMAL). The value.ul2 field
contains the old Disk Group state. The state values that may be found in the
value.ul2 field are as follows: 2 = Disk Group with no redundancy is inoperative
3 = Disk Group with parity redundancy is inoperative 4 = Disk Group with
mirrored redundancy is inoperative 5 = Disk Group with no redundancy is
inoperative, marked for re-use 6 = Disk Group with parity redundancy is
inoperative, marked for re-use 7 = Disk Group with mirrored redundancy is
inoperative, marked for re-use
2332
8803091c
2
9
1c
Storage Cell: %1 Event Code: %2 Description: The Occupancy Alarm Level for
the Disk Group identified in the handle field has returned to the normal range.
Storage Management Appliance Software Event Code Definitions Application Notes
35
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
2333
2334
2335
2336
2337
2338
2339
8803091d
8803091e
8803091f
88030920
88030921
88030922
88030923
6
9
1d
1e
1f
Storage Cell: %1 Event Code: %2 Description: The Battery In Use flag for battery
assembly ‘1’ located within the HSV110 controller identified in the handle field
has transitioned from the IN USE to NOT IN USE state indicating that the battery
assembly has malfunctioned. The secondary_id field contains the battery
assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state
of the Battery In Use flag: 0 (NOT IN USE). The value.ul2 field contains the old
state of the Battery In Use flag: 1 (IN USE).
2
6
2
2
6
6
9
9
9
9
9
9
Storage Cell: %1 Event Code: %2 Description: The Battery Present flag for
battery assembly ‘1’ located within the HSV110 controller identified in the
handle field has changed from NOT PRESENT to PRESENT indicating that the
battery assembly was reinstalled. The secondary_id field contains the battery
assembly ‘1’ internal identifier value: 1. The value.ul1 field contains the new state
of the Battery Present flag: 1 (PRESENT). The value.ul2 field contains the old state
of the Battery Present flag: 0 (NOT PRESENT).
Storage Cell: %1 Event Code: %2 Description: The Battery Present flag for
battery assembly ‘2’ located within the HSV110 controller identified in the
handle field has changed from PRESENT to NOT PRESENT indicating that the
battery assembly was removed. The secondary_id field contains the battery
assembly ‘2’ internal identifier value: 2. The value.ul1 field contains the new state
of the Battery Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old
state of the Battery Present flag: 1 (PRESENT).
20
21
22
23
Storage Cell: %1 Event Code: %2 Description: The Battery Present flag for
battery assembly ‘2’ located within the HSV110 controller identified in the
handle field has changed from NOT PRESENT to PRESENT indicating that the
battery assembly was reinstalled. The secondary_id field contains the battery
assembly ‘2’ internal identifier value: 2. The value.ul1 field contains the new state
of the Battery Present flag: 1 (PRESENT). The value.ul2 field contains the old state
of the Battery Present flag: 0 (NOT PRESENT).
Storage Cell: %1 Event Code: %2 Description: The Battery In Use flag for battery
assembly ‘2’ located within the HSV110 controller identified in the handle field
has transitioned from the NOT IN USE to IN USE state indicating that the battery
assembly is functioning properly. The secondary_id field contains the battery
assembly ‘2’ internal identifier value: 2. The value.ul1 field contains the new state
of the Battery In Use flag: 1 (IN USE). The value.ul2 field contains the old state of
the Battery In Use flag: 0 (NOT IN USE).
Storage Cell: %1 Event Code: %2 Description: The Battery In Use flag for battery
assembly ‘2’ located within the HSV110 controller identified in the handle field
has transitioned from the IN USE to NOT IN USE state indicating that the battery
assembly has malfunctioned. The secondary_id field contains the battery
assembly ‘2’ internal identifier value: 2. The value.ul1 field contains the new state
of the Battery In Use flag: 0 (NOT IN USE). The value.ul2 field contains the old
state of the Battery In Use flag: 1 (IN USE).
Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘2’
blower assembly located within the HSV110 controller identified in the handle
field has transitioned from the PRESENT to NOT PRESENT state indicating that
the blower has been removed. The secondary_id field contains the ‘2’ blower
assembly internal identifier value: 2. The value.ul1 field contains the new state of
the Blower Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old
state of the Blower Present flag: 1 (PRESENT).
36
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
2340
88030924
2
9
24
Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘2’
blower assembly located within the HSV110 controller identified in the handle
field has transitioned from the NOT PRESENT to PRESENT state indicating that
the blower has been reinstalled. The secondary_id field contains the ‘2’ blower
assembly internal identifier value: 2. The value.ul1 field contains the new state of
the Blower Present flag: 1 (PRESENT). The value.ul2 field contains the old state of
the Blower Present flag: 0 (NOT PRESENT).
2341
2342
88030925
88030926
6
6
9
9
25
26
Storage Cell: %1 Event Code: %2 Description: The ‘2’ blower located within the
HSV110 controller identified in the handle field is running slower than the lowest
acceptable speed. The secondary_id field contains the ‘2’ blower assembly
internal identifier value: 2. The value.ul1 field contains the current speed of the
‘2’ blower. The value.ul2 field contains the lowest acceptable speed for the ‘2’
blower.
Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present
flag for the ‘1’ blower/power supply assembly located within the HSV110
controller identified in the handle field has transitioned from the PRESENT to
NOT PRESENT state indicating that the blower/power supply has been removed.
The secondary_id field contains the ‘1’ blower/power supply assembly internal
identifier value: 1. The value.ul1 field contains the new state of the Blower/Power
Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state
of the Blower/Power Supply Present flag: 1 (PRESENT).
2343
2344
2345
2346
88030927
88030928
88030929
8803092a
2
6
2
6
9
9
9
9
27
28
29
2a
Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present
flag for the ‘1’ blower/power supply assembly located within the HSV110
controller identified in the handle field has transitioned from the NOT PRESENT
to PRESENT state indicating that the blower/power supply has been reinstalled.
The secondary_id field contains the ‘1’ blower/power supply assembly internal
identifier value: 1. The value.ul1 field contains the new state of the Blower/Power
Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the
Blower/Power Supply Present flag: 0 (NOT PRESENT).
Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present
flag for the ‘2’ blower/power supply assembly located within the HSV110
controller identified in the handle field has transitioned from the PRESENT to
NOT PRESENT state indicating that the blower/power supply has been removed.
The secondary_id field contains the ‘2’ blower/power supply assembly internal
identifier value: 2. The value.ul1 field contains the new state of the Blower/Power
Supply Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old state
of the Blower/Power Supply Present flag: 1 (PRESENT).
Storage Cell: %1 Event Code: %2 Description: The Blower/Power Supply Present
flag for the ‘2’ blower/power supply assembly located within the HSV110
controller identified in the handle field has transitioned from the NOT PRESENT
to PRESENT state indicating that the blower/power supply has been reinstalled.
The secondary_id field contains the ‘2’ blower/power supply assembly internal
identifier value: 2. The value.ul1 field contains the new state of the Blower/Power
Supply Present flag: 1 (PRESENT). The value.ul2 field contains the old state of the
Blower/Power Supply Present flag: 0 (NOT PRESENT).
Storage Cell: %1 Event Code: %2 Description: The ‘1’ blower/power supply
located within the HSV110 controller identified in the handle field is running
slower than the lowest acceptable speed. The secondary_id field contains the ‘1’
blower/power supply assembly internal identifier value: 1. The value.ul1 field
contains the current speed of the ‘1’ blower/power supply. The value.ul2 field
contains the lowest acceptable speed for the ‘1’ blower/power supply.
Storage Management Appliance Software Event Code Definitions Application Notes
37
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
2347
8803092b
6
9
2b
Storage Cell: %1 Event Code: %2 Description: The ‘2’ blower/power supply
located within the HSV110 controller identified in the handle field is running
slower than the lowest acceptable speed. The secondary_id field contains the ‘2’
blower/power supply assembly internal identifier value: 2. The value.ul1 field
contains the current speed of the ‘2’ blower/power supply. The value.ul2 field
contains the lowest acceptable speed for the ‘2’ blower/power supply.
2348
8803092c
3
9
2c
Storage Cell: %1 Event Code: %2 Description: The state of a battery assembly
within the HSV110 controller identified in the handle field has transitioned to the
Battery System Hold-up Time is zero hours state. The value.ul1 field contains the
new state 3: (Battery System Hold-up Time is zero hours). The value.ul2 field
contains the old state. The state values that may be found in the value.ul2 field
are as follows: 1 = Battery System Hold-up Time is greater than 96 hours 3 =
Battery System Hold-up Time is greater than 0 and less than 96 hours
2349
2350
8803092d
8803092e
6
2
9
9
2d
2e
Storage Cell: %1 Event Code: %2 Description: The Resource Availability state of
the Volume identified in the handle field has transitioned to the INSUFFICIENT
state. The value.ul1 field contains the new state: 1 (INSUFFICIENT). The value.ul2
field contains the old state: 0 (SUFFICIENT).
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the handle field rejected a login attempt. The value.ul1 and value.ul2 fields
contain words [0] and [1], respectively, of the World Wide Name of the host
adapter that originated the rejected login attempt. The secondary_id field
contains the reason for the rejection as follows: 50 = The host is already logged
in 101 = Maximum number of logins is exceeded 102 = Invalid cookie was sent
106 = The password is not set on the HSV110 controller
2351
2352
8803092f
88030930
2
2
9
9
2f
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the handle field processed a StorageCell Management Interface command
with the result of non-success return code. The value.ul1 field contains the
command type. The value.ul2 field contains the return code.
30
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the handle field has updated the physical disk drive map for the loop pair
identified in the secondary_id field. The value.ul1 field contains the new internal
map generation number. The value.ul2 field contains the old internal map
generation number.
2353
2354
2355
2356
88030931
88030932
88030933
88030934
6
6
2
2
9
9
9
9
31
32
33
34
Storage Cell: %1 Event Code: %2 Description: The state of the Physical Disk
Drive identified in the handle field has transitioned to the DEGRADED state. The
value.ul1 field contains the new state: 2 (DEGRADED). The value.ul2 field
contains the old state. The state values that may be in the value.ul2 field are as
follows: 1 = Normal 3 = Failed 4 = Not present
Storage Cell: %1 Event Code: %2 Description: The state of the Physical Disk
Drive identified in the handle field has transitioned to the FAILED state. The
value.ul1 field contains the new state: 3 (FAILED). The value.ul2 field contains the
old state. The state values that may be in the value.ul2 field are as follows: 1 =
Normal 2 = Degraded 4 = Not present
Storage Cell: %1 Event Code: %2 Description: The Derived Unit identified in the
handle field was created. The add_handle field contains the identity of the
Storage System Virtual Disk that is associated with that Derived Unit. The
atribute.value.obj field contains the identity of the Virtual Disk associated with
that Derived Unit.
Storage Cell: %1 Event Code: %2 Description: The internal Logical Disk
associated with the Virtual Disk identified in the handle field was created.
38
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
2357
88030935
2
9
35
Storage Cell: %1 Event Code: %2 Description: The Disk Group identified in the
handle field was created.
2358
88030936
2
2
9
9
36
Storage Cell: %1 Event Code: %2 Description: The Physical Disk Drive identified
in the handle field was discovered. The enclosure number and bay number where
the Physical Disk Drive is located are contained in the attribute.value.u32[0] and
attribute.value.u32[1] fields, respectively. The attribute.type field contains the
value 1.
2359
88030937
37
Storage Cell: %1 Event Code: %2 Description: The Presented Unit identified in
the handle field was created. The add_handle field contains the identity of the
Storage System Virtual Disk that is associated with the Presented Unit. This
Presented Unit is associated with the Virtual Disk identified in the
attribute.value.obj.handle field.
2360
2361
2362
88030938
88030939
8803093a
2
2
2
9
9
9
38
39
3a
Storage Cell: %1 Event Code: %2 Description: The Storage System Host path
identified in the handle field was created.
Storage Cell: %1 Event Code: %2 Description: The Storage System Virtual Disk
identified in the handle field was created.
Storage Cell: %1 Event Code: %2 Description: The Volume identified in the
handle field was created. The add_handle field contains the identity of the
Physical Disk Drive that is associated with the Volume.
2363
8803093b
2
9
3b
Storage Cell: %1 Event Code: %2 Description: The Derived Unit identified in the
handle field was deleted. The add_handle field contains the identity of the
Storage System Virtual Disk that was associated with the Derived Unit. This
Derived Unit is associated with the Virtual Disk identified in the
attribute.value.obj.handle field.
2364
2365
2366
8803093c
8803093d
8803093e
2
2
6
9
9
9
3c
3d
3e
Storage Cell: %1 Event Code: %2 Description: The internal Logical Disk
associated with the Virtual Disk identified in the handle field was deleted.
Storage Cell: %1 Event Code: %2 Description: The Disk Group identified in the
handle field was deleted.
Storage Cell: %1 Event Code: %2 Description: The Physical Disk Drive identified
in the handle field has disappeared. The enclosure number and bay number
where the Physical Disk Drive was located are contained in the
attribute.value.u32[0] and attribute.value.u32[1] fields, respectively. The
attribute.type field contains the value 1.
2367
8803093f
2
9
3f
Storage Cell: %1 Event Code: %2 Description: The Presented Unit identified in
the handle field was deleted. The add_handle field contains the identity of the
Storage System Virtual Disk that was associated with the Presented Unit. This
Presented Unit is associated with the Virtual Disk identified in the
attribute.value.obj.handle field.
2368
2369
88030940
88030941
2
2
9
9
40
41
Storage Cell: %1 Event Code: %2 Description: The Storage System Host path
identified in the handle field was deleted.
Storage Cell: %1 Event Code: %2 Description: The Storage System Virtual Disk
identified in the handle field was deleted. The Storage System Virtual Disk is
associated with the Virtual Disk identified in the add_handle field.
2370
88030942
6
9
42
Storage Cell: %1 Event Code: %2 Description: The Snapshot Logical Disk
identified in the handle field has been marked inoperative due to the Disk Group
being out of space for additional storage allocation.
Storage Management Appliance Software Event Code Definitions Application Notes
39
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
2371
2372
2373
88030943
88030944
88030945
2
9
43
44
45
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the handle field has joined the Storage System. If the handle field is zero, the
HSV110 controller identity could not be obtained due to an unexpected state
transition.
6
2
9
9
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the handle field has left the Storage System. If the handle field is zero, the
HSV110 controller identity could not be obtained due to an unexpected state
transition.
Storage Cell: %1 Event Code: %2 Description: The Storage System identified by
the handle field was deleted by the HSV110 controller identified in the
add_handle field. If the handle field or add_handle field is zero, the
corresponding identity could not be obtained due to an unexpected state
transition.
2405
88030965
2
9
65
Storage Cell: %1 Event Code: %2 Description: The Host Operating System mode
of the Storage System Host identified in the handle field has changed. The
old_attr.type and new_attr.type fields contain the value 1. The
old_attr.value.u32[0] field contains the old Host Operating System mode. The
new_attr.value.u32[0] field contains the new Host Operating System mode. The
values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0]
fields are as follows: 0 = Unknown 1 = User defined 2 = Unused 3 = WINNT
with SecurePath 4 = VMS 5 = TRU64 UNIX 6 = Sun UNIX 7 = NetWare 8 = HP
9 = IBM 10 = LINUX 11 = SCO UNIX
2406
2407
88030966
88030967
2
2
9
9
66
67
Storage Cell: %1 Event Code: %2 Description: Time was set on the Storage
System identified in the handle field.
Storage Cell: %1 Event Code: %2 Description: The LUN of the Presented Unit
identified in the handle field has changed. The old_attr.type field and the
new_attr.type fields contain the value 1. The old_attr.value.u32[0..1] fields
contain the value of the old LUN. The new_attr.value.u32[0..1] fields contain the
value of the new LUN. The secondary_id field contains the noid portion of the
handle for the Storage System Virtual Disk associated with the Presented Unit.
This Presented Unit is associated with the Virtual Disk identified in the
add_handle field.
2408
2409
88030968
88030969
2
2
9
9
68
69
Storage Cell: %1 Event Code: %2 Description: The Device Addition Policy of the
Storage System identified in the handle field has changed. The old_attr.type field
and the new_attr.type fields contain the value 1. The old_attr.value.u32[0] field
contains the old Device Addition Policy. The new_attr.value.u32[0] field contains
the new Device Addition Policy. The policy values that may be found in the
old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 =
Manual policy 2 = Automatic policy
Storage Cell: %1 Event Code: %2 Description: The Quiescent state of the
Storage System Virtual Disk identified in the handle field has changed. The
old_attr.type field and the new_attr.type fields contain the value 1. The
old_attr.value.u32[0] field contains the old Quiescent state. The
new_attr.value.u32[0] field contains the new Quiescent state. The state values
that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0] fields
are as follows: 0 = FALSE 1 = TRUE This Storage System Virtual Disk is associated
with the Virtual Disk identified in the add_handle field.
40
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
2410
8803096a
2
9
6a
Storage Cell: %1 Event Code: %2 Description: The Enabled/Disabled state of
the Storage System Virtual Disk identified in the handle field has changed. The
old_attr.type field and the new_attr.type fields contain the value 1. The
old_attr.value.u32[0] field contains the old Enabled/Disabled state. The
new_attr.value.u32[0] field contains the new Enabled/Disabled state. The state
values that may be found in the old_attr.value.u32[0] and new_attr.value.u32[0]
fields are as follows: 1 = Disabled 2 = Enabled This Storage System Virtual Disk
is associated with the Virtual Disk identified in the add_handle field.
2411
8803096b
2
9
6b
Storage Cell: %1 Event Code: %2 Description: The Cache Policy of the Storage
System Virtual Disk identified in the handle field has changed. The old_attr.type
field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0]
field contains the old Write Cache Policy. The new_attr.value.u32[0] field
contains the new Write Cache Policy. The policy values that may be found in the
old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 =
Writethrough 2 = Writeback The old_attr.value.u32[1] field contains the old
Read Cache Policy. The new_attr.value.u32[1] field contains the new Read Cache
Policy. The policy values that may be found in the old_attr.value.u32[1] and
new_attr.value.u32[1] fields are as follows: 1 = Read cache on 2 = Read cache
off The old_attr.value.u32[2] field contains the old Cache Mirroring Policy. The
new_attr.value.u32[2] field contains the new Cache Mirroring Policy. The policy
values that may be found in the old_attr.value.u32[2] and new_attr.value.u32[ 2]
fields are as follows: 1 = Mirror 2 = No mirror This Storage System Virtual Disk is
associated with the Virtual Disk identified in the add_handle field.
2412
2413
2414
8803096c
8803096d
8803096e
2
2
2
9
9
9
6c
6d
6e
Storage Cell: %1 Event Code: %2 Description: The Usage state of the Volume
identified in the handle field has changed. The old_attr.value.u32[0] field
contains the old Usage state. The new_attr.value.u32[0] field contains the new
Usage state. The Usage state values that may be found in the
old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 1 = Disk
Group 2 = Reserved
Storage Cell: %1 Event Code: %2 Description: The Disk Failure Protection Level
of the Disk Group identified in the handle field has changed. The old_attr.type
and new_attr.type fields contain the value 1. The old_attr.value.u32[0] field
contains the old number of physical disk drives available for use. The
new_attr.value.u32[0] field contains the new number of physical disk drives
available for use.
Storage Cell: %1 Event Code: %2 Description: The Write Protected state of the
Derived Unit identified in the handle field has changed. The secondary_id field
contains the noid portion of the handle for the Storage System Virtual Disk
associated with the Derived Unit. The old_attr.type field and the new_attr.type
fields contain the value 1. The old_attr.value.u32[0] field contains the old Write
Protected state. The new_attr.value.u32[0] field contains the new Write Protected
state. The Write Protected state values that may be found in the
old_attr.value.u32[0] and new_attr.value.u32[0] fields are as follows: 0 = Write
protect off 1 = Write protect on This Derived Unit is associated with the Virtual
Disk identified in the add_handle field.
2416
88030970
3
9
70
Storage Cell: %1 Event Code: %2 Description: The Physical Disk Drive identified
in the handle field has experienced numerous communication failures on a
particular Fibre Channel port.
Storage Management Appliance Software Event Code Definitions Application Notes
41
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
2417
88030971
2
9
71
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the handle field received a request to shutdown. The old_attr.type field and the
new_attr.type fields contain the value 1. The old_attr.value.u32[0] field indicates
the type of restart that was requested as follows: 0 = None -- no restart 1 =
Regular -- full restart, host system connectivity is lost until the controller returns to
normal operation 2 = Fast -- resynchronization, restart of the controller in a
manner that has little or no impact on host system connectivity The
old_attr.value.u32[1] field indicates whether the other HSV110 controller of the
pair was requested to remain operational or to also shutdown as follows: 0 =
Remain operational 1 = Coupled shutdown The old_attr.value.u32[2] field
indicates whether the HSV110 controller was requested to remain in the power
on state or power itself off as follows: 0 = Remain in the power on state 1 =
Power itself off The old_attr.value.u32[3] field value indicates whether the
Physical Disk Drive enclosure(s) was requested to remain in the power on state or
to be powered off as follows: 0 = Remain in the power on state 1 = Powered off
The old_attr.value.u32[4] field value indicates whether the battery assemblies
located within the HSV110 controller were requested to be enabled or disabled
as follows: 0 = Enabled 1 = Disabled The old_attr.value.u32[5] field contains the
number of seconds the shutdown operation was requested to be delayed.
2418
88030972
2
9
72
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the handle field has completed its shutdown preparations. The old_attr.type
field and the new_attr.type fields contain the value 1. The old_attr.value.u32[0]
field value indicates the result of the HSV110 controller Cache Memory shutdown
operation as follows: 1 = Success 2 = Failure 3 = Not applicable The
old_attr.value.u32[1] field contains the internal Storage System Management
Interface cache shutdown status code. The old_attr.value.u32[2] field value
indicates the result of the Physical Disk Drive enclosure(s) power off operation as
follows: 1 = Success 2 = Failure 3 = Not applicable The old_attr.value.u32[3]
field contains the internal Storage System Management Interface Physical Disk
Drive enclosure(s) power off status code. The old_attr.value.u32[4] field value
indicates the result of the battery assemblies disable operation as follows: 1 =
Success 2 = Failure 3 = Not applicable <P > The old_attr.value.u32[5] field value
indicates the battery assemblies disable operation failure mode as follows: 0 =
No failure indicated. 1 = Failed only on the HSV110 controller identified in the
handle field. 2 = Failed only on the other HSV110 controller of the pair. 3 =
Failed on both HSV110 controllers.
2504
2505
880309c8
880309c9
6
6
9
9
c8
c9
Storage Cell: %1 Event Code: %2 Description: The Data Availability state of the
internal Logical Disk associated with the Virtual Disk identified in the handle field
has has transitioned to the DATA LOST state. The value.ul1 field contains the new
state: 1 (DATA LOST). The value.ul2 field contains the old state: 0 (NORMAL).
Storage Cell: %1 Event Code: %2 Description: The state of the Disk Group
identified in the handle field has transitioned to an INOPERATIVE state. The
value.ul1 field contains the new Disk Group state. The value.ul2 field contains the
old Disk Group state. The state values that may be found in the value.ul1 and
value.ul2 fields are as follows: 1 = Normal 2 = Disk Group with no redundancy
is inoperative 3 = Disk Group with parity redundancy is inoperative 4 = Disk
Group with mirrored redundancy is inoperative 5 = Disk Group with no
redundancy is inoperative, marked for re-use 6 = Disk Group with parity
redundancy is inoperative, marked for re-use 7 = Disk Group with mirrored
redundancy is inoperative, marked for re-use
42
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
2506
2507
2508
880309ca
880309cb
880309cc
6
9
ca
cb
cc
Storage Cell: %1 Event Code: %2 Description: The state of the internal Logical
Disk associated with the Virtual Disk identified in the handle field has transitioned
to the FAILED state. The value.ul1 field contains the new state: 5 (FAILED). The
value.ul2 field contains the old state. The state values that may be found in the
value.ul2 field are as follows: 1 = Normal 2 = Replacement delay in progress 3 =
Redundancy lost, restore in progress 4 = Redundancy lost, restore stalled 6 =
Creation in progress 7 = Snapshot is inoperative due to lack of snapshot space 8
= Deletion in progress 9 = Capacity change in progress 10 = Inoperative due to
data lost
6
6
9
9
Storage Cell: %1 Event Code: %2 Description: The state of the internal Logical
Disk associated with the Virtual Disk identified in the handle field has transitioned
to the SNAPSHOT OVERCOMMIT state. The value.ul1 field contains the new
state: 7 (SNAPSHOT OVERCOMMIT). The value.ul2 field contains the old state.
The state values that may be found in the value.ul2 field are as follows: 1 =
Normal 2 = Replacement delay in progress 3 = Redundancy lost, restore in
progress 4 = Redundancy lost, restore stalled 5 = Failed 6 = Creation in progress
8 = Deletion in progress 9 = Capacity change in progress 10 = Inoperative due
to device data lost
Storage Cell: %1 Event Code: %2 Description: The state of the internal Logical
Disk associated with the Virtual Disk identified in the handle field has transitioned
to the DEVICE DATA LOST state. The value.ul1 field contains the new state: 10
(DEVICE DATA LOST). The value.ul2 field contains the old state. The state values
that may be found in the value.ul2 field are as follows: 1 = Normal 2 =
Replacement delay in progress 3 = Redundancy lost restore, in progress 4 =
Redundancy lost restore, stalled 5 = Failed 6 = Creation in progress 7 =
Snapshot is inoperative due to lack of snapshot space 8 = Deletion in progress 9
= Capacity change in progress
2509
2510
880309cd
880309ce
6
2
9
9
cd
ce
Storage Cell: %1 Event Code: %2 Description: The state of the Fibre Channel
port identified in the attribute.value.str field and located on the rear panel of the
HSV110 controller identified in the handle field has transitioned to the FAILED
state. The attribute.type field contains the value 4. The value.ul1 field contains
the new state: 2 (FAILED). The value.ul2 field contains the old state: 1
(NORMAL). Note that the HSV110 controller’s internal identity of the affected
Fibre Channel port is contained in the secondary_id field.
Storage Cell: %1 Event Code: %2 Description: The state of the Disk Group
identified in the handle field has transitioned to an INOPERATIVE MARKED state.
The value.ul1 field contains the new Disk Group state. The value.ul2 field
contains the old Disk Group state. The state values that may be found in the
value.ul1 and value.ul2 fields are as follows: 1 = Normal 2 = Disk Group with no
redundancy is inoperative 3 = Disk Group with parity redundancy is inoperative
4 = Disk Group with mirrored redundancy is inoperative 5 = Disk Group with no
redundancy is inoperative, marked for re-use 6 = Disk Group with parity
redundancy is inoperative, marked for re-use 7 = Disk Group with mirrored
redundancy is inoperative, marked for re-use
2511
2512
880309cf
880309d0
3
2
9
9
cf
Storage Cell: %1 Event Code: %2 Description: The state of the Physical Disk
Drive identified in the handle field has transitioned to the NOT PRESENT state.
The value.ul1 field contains the new state: 4 (NOT PRESENT). The value.ul2 field
contains the old state. The state values that may be in the value.ul2 field are as
follows: 1 = Normal 2 = Degraded 3 = Failed
d0
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the handle field no longer needs attention.
Storage Management Appliance Software Event Code Definitions Application Notes
43
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
2513
880309d1
6
9
d1
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
in the handle field needs attention.
2514
880309d2
6
9
d2
Storage Cell: %1 Event Code: %2 Description: The Blower Present flag for the ‘1’
blower assembly located within the HSV110 controller identified in the handle
field has transitioned from the PRESENT to NOT PRESENT state indicating that
the blower has been removed. The secondary_id field contains the ‘1’ blower
assembly internal identifier value: 1. The value.ul1 field contains the new state of
the Blower Present flag: 0 (NOT PRESENT). The value.ul2 field contains the old
state of the Blower Present flag: 1 (PRESENT).
2816
88030b00
2
b
0
Storage Cell: %1 Event Code: %2 Description: The HSV110 controller identified
by the node_name field has begun a resynchronization operation (i.e., a restart
of the controllers in a manner that has little or no impact on host system
connectivity). The information.pc field contains the program counter of
resynchronization operation initiator. The information.flags field contains reboot
flags value. The information.code field contains the resynchronization operation
event code value.
3072
3073
88030c00
88030c01
2
6
c
c
0
1
Storage Cell: %1 Event Code: %2 Description: The specified destination virtual
disk has successfully completed a full copy. The following fields are not valid:
status, blocks, vda.
Storage Cell: %1 Event Code: %2 Description: The specified source virtual disk
has transitioned to the logging state, because the alternate site is not accessible
or the DRM group is suspended. The following fields are not valid: status, blocks,
vda, port, side.
3074
3076
88030c02
88030c04
6
6
c
c
2
4
Storage Cell: %1 Event Code: %2 Description: The specified source virtual disk
has transitioned to the logging state, because the destination virtual disk is not
accessible. The following fields are not valid: status, blocks, vda, port, side.
Storage Cell: %1 Event Code: %2 Description: The specified source virtual disk
has been forced inoperative due to a failsafe locked condition. Either the
destination is not accessible or a member virtual disk in the group has gone
inoperative. The following fields are not valid: status, blocks, vda, port, side.
3077
3078
3079
3080
3081
88030c05
88030c06
88030c07
88030c08
88030c09
6
6
6
6
6
c
c
c
c
c
5
6
7
8
9
Storage Cell: %1 Event Code: %2 Description: The specified source virtual disk
has been forced inoperative due to a failsafe locked condition. Either the
destination is not accessible or a member virtual disk in the group has gone
inoperative. The following fields are not valid: status, blocks, vda, port, side.
Storage Cell: %1 Event Code: %2 Description: An unrecoverable read error
occurred on the specified source virtual disk during the full copy. The virtual disk
address (vda) specified indicates the first block in error. The full copy was
terminated.
Storage Cell: %1 Event Code: %2 Description: A full copy terminated prior to
completion. A remote copy error occurred, due to an inaccessible alternate site.
The virtual disk address specified indicates the first block in error. The full copy
will continue when the destination is restored.
Storage Cell: %1 Event Code: %2 Description: A full copy terminated prior to
completion. A remote copy error occurred, due to an inaccessible destination
virtual disk. The virtual disk address specified indicates the first block in error.
The full copy will continue when the destination is restored.
Storage Cell: %1 Event Code: %2 Description: The specified log logical disk has
been reset due to insufficient storage space. The destination has been marked
for a full copy. The following fields are not valid: status, blocks, vda, port, side.
44
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
3082
3084
3087
3088
3089
3090
3092
88030c0a
88030c0c
88030c0f
88030c10
88030c11
88030c12
88030c14
2
c
a
Storage Cell: %1 Event Code: %2 Description: The specified log logical disk has
been reset due to site failover. The following fields are not valid: status, blocks,
vda.
2
2
2
2
2
6
c
c
c
c
c
c
c
Storage Cell: %1 Event Code: %2 Description: The specified destination virtual
disk has successfully completed a merge. The following fields are not valid:
status, blocks, vda.
f
Storage Cell: %1 Event Code: %2 Description: The specified virtual disk is no
longer failsafe locked. The following fields are not valid: status, blocks, vda, port,
side.
10
11
12
14
Storage Cell: %1 Event Code: %2 Description: The specified destination virtual
disk has been marked for a full copy. The following fields are not valid: status,
blocks, vda.
Storage Cell: %1 Event Code: %2 Description: This site has just discovered that a
site failover has taken place. This group is transitioning from a source role to a
destination role. The following fields are not valid: status, blocks, vda.
Storage Cell: %1 Event Code: %2 Description: This site has just discovered that a
site failover has taken place. This group is transitioning from a destination role to
a source role. The following fields are not valid: status, blocks, vda.
Storage Cell: %1 Event Code: %2 Description: The specified destination DRM
group was not found. The destination group appears to have been deleted by
the user after a site failover, therefore this dangling DRM source group should
likewise be deleted.
3328
3329
88030d00
88030d01
6
6
d
d
0
1
Storage Cell: %1 Event Code: %2 Description: Unrecognized event reported by
a Drive Enclosure Environmental Monitoring Unit. The event was reported by the
Drive Enclosure Environmental Monitoring Unit located in the drive enclosure
identified in the dencl_num field within the rack identified in the rack_num field.
The rack_num field will not be valid until a future release. The content of the
alarm_error_code field could not be translated into a known event.
Storage Cell: %1 Event Code: %2 Description: A physical disk drive that is not
Fibre Channel compatible or cannot operate at the link rate established by the
drive enclosure I/O modules was detected. This problem was detected by the
Drive Enclosure Environmental Monitoring Unit located in the drive enclosure
identified in the dencl_num field within the rack identified in the rack_num field
during spin up of the physical disk drive installed in the drive enclosure bay
identified in the alarm_error_code.field.en field. The rack_num field will not be
valid until a future release.
3330
3331
88030d02
88030d03
3
3
d
d
2
3
Storage Cell: %1 Event Code: %2 Description: A physical disk drive is
improperly installed or missing. This could affect the drive enclosure air flow and
cause an over temperature condition. This problem was detected by the Drive
Enclosure Environmental Monitoring Unit located in the drive enclosure identified
in the dencl_num field within the rack identified in the rack_num field. The
rack_num field will not be valid until a future release. The affected drive enclosure
bay is identified in the alarm_error_code.field.en field.
Storage Cell: %1 Event Code: %2 Description: A physical disk drive was
removed while software-activated drive locking was enabled on a drive enclosure
that does not support drive locking. This problem was detected by the Drive
Enclosure Environmental Monitoring Unit located in the drive enclosure identified
in the dencl_num field within the rack identified in the rack_num field. The
rack_num field will not be valid until a future release. The affected drive enclosure
bay is identified in the alarm_error_code.field.en field.
Storage Management Appliance Software Event Code Definitions Application Notes
45
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
3332
88030d04
6
d
4
Storage Cell: %1 Event Code: %2 Description: A physical disk drive that is
capable of operating at the loop link rate established by the drive enclosure I/O
module was found to be running at a different rate. This problem was detected
by the Drive Enclosure Environmental Monitoring Unit located in the drive
enclosure identified in the dencl_num field within the rack identified in the
rack_num field. The rack_num field will not be valid until a future release. The
affected physical disk drive is installed in the drive enclosure bay identified in the
alarm_error_code.field.en field. The Fibre Channel loop on which the problem
was detected is identified by the content of the alarm_error_code.field.ec field as
follows: 4 = loop A 5 = loop B
3379
3380
88030d33
88030d34
3
6
d
d
33
34
Storage Cell: %1 Event Code: %2 Description: The AC input to a drive enclosure
power supply has been lost. This makes the remaining power supply a single
point of failure. This problem was detected by the Drive Enclosure Environmental
Monitoring Unit located in the drive enclosure identified in the dencl_num field
within the rack identified in the rack_num field. The rack_num field will not be
valid until a future release. The location of the affected power supply (1 or 2) is
identified in the alarm_error_code.field.en field.
Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply is
improperly installed or missing. This could affect the drive enclosure air flow and
cause an over temperature condition. The operational power supply will
automatically shut down after a short period of time, thereby disabling the drive
enclosure. This condition remains active until either the problem is corrected, or
the operational power supply shuts down, whichever occurs first. This problem
was detected by the Drive Enclosure Environmental Monitoring Unit located in the
drive enclosure identified in the dencl_num field within the rack identified in the
rack_num field. The rack_num field will not be valid until a future release. The
location of the affected power supply (1 or 2) is identified in the
alarm_error_code.field.en field.
3381
88030d35
6
d
35
Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply
component has failed. This problem was detected by the Drive Enclosure
Environmental Monitoring Unit located in the drive enclosure identified in the
dencl_num field within the rack identified in the rack_num field. The rack_num
field will not be valid until a future release. The location of the affected power
supply (1 or 2) is identified in the alarm_error_code.field.en field.
46
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
3399
88030d47
6
d
47
Storage Cell: %1 Event Code: %2 Description: A drive enclosure blower is not
operating properly. This could affect the drive enclosure air flow and cause an
over temperature condition. This problem was detected by the Drive Enclosure
Environmental Monitoring Unit located in the drive enclosure identified in the
dencl_num field within the rack identified in the rack_num field.The rack_num
field will not be valid until a future release. The location of the affected blower (1
or 2) is identified in the alarm_error_code.field.en field. The cause of the
improper operation is described by the content of the alarm_error_code.field.ec
field as follows: 1 = The blower is operating at a speed that is outside of the Drive
Enclosure Environmental Monitoring Unit specified range, possibly because of a
bearing problem. 2 = The blower is operating at a speed that is significantly
outside of the Drive Enclosure Environmental Monitoring Unit specified range,
possibly because of a bearing problem. 3 = The blower has stopped.
NOTE: The other blower (if operational) now operates at high speed and is a
single point of failure. A single blower operating at high speed can provide
sufficient air flow to cool an enclosure and the elements for up to 100 hours.
However, operating an enclosure at temperatures approaching an overheating
threshold can damage elements and may reduce the MTBF of a specific element.
Compaq therefore recommends immediate replacement of the defective blower.
4 = The power supply reported an internal blower error.
3403
3404
88030d4b
88030d4c
6
6
d
d
4b
4c
Storage Cell: %1 Event Code: %2 Description: A drive enclosure blower is
improperly installed or missing. This affects the drive enclosure air flow and can
cause an over temperature condition. This problem was detected by the Drive
Enclosure Environmental Monitoring Unit located in the drive enclosure identified
in the dencl_num field within the rack identified in the rack_num field. The
rack_num field will not be valid until a future release. The location of the affected
blower (1 or 2) is identified in the alarm_error_code.field.en field.
Storage Cell: %1 Event Code: %2 Description: Both drive enclosure blowers are
missing. This severely affects the drive enclosure air flow and can cause an over
temperature condition. The operational power supply(s) will automatically shut
down after a short period of time, thereby disabling the drive enclosure. This
condition remains active until either the problem is corrected, or the operational
power supply(s) shut down, whichever occurs first. This problem was detected by
the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure
identified in the dencl_num field within the rack identified in the rack_num field.
The rack_num field will not be valid until a future release. Note that this event is
preceded by a ‘drive enclosure blower is improperly installed or missing’ event
that identifies the location of the first missing blower. The location of the second
missing blower (1 or 2) is identified in the alarm_error_code.field.en field of this
event.
Storage Management Appliance Software Event Code Definitions Application Notes
47
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
3419
88030d5b
3
d
5b
Storage Cell: %1 Event Code: %2 Description: A drive enclosure temperature
sensor out of range condition has been reported by one of the drive enclosure
elements. This problem was detected by the Drive Enclosure Environmental
Monitoring Unit located in the drive enclosure identified in the dencl_num field
within the rack identified in the rack_num field. The rack_num field will not be
valid until a future release. The location of the temperature sensor (1 through 11)
is identified in the alarm_error_code.field.en field as follows: 1 = Power Supply 1
Exhaust 2 = Power Supply 2 Exhaust 3 = Drive Enclosure Environmental
Monitoring Unit 4 = Drive Bay 1 5 = Drive Bay 2 6 = Drive Bay 3 7 = Drive
Bay 4 8 = Drive Bay 5 9 = Drive Bay 6 A = Drive Bay 7 B = Drive Bay 8 C =
Drive Bay 9 D = Drive Bay 10 E = Drive Bay 11 F = Drive Bay 12 10 = Drive
Bay 13 11 = Drive Bay 14 The temperature sensor out of range condition is
described by the content of the alarm_error_code.fie ld.ec field as follows: 1 =
The element temperature is approaching, but has not reached, the high
temperature CRITICAL threshold. Continued operation under these conditions
may result in a CRITICAL condition and may reduce an element’s MTBF. 2 = The
element temperature is above the high temperature CRITICAL threshold.
Continued operation under these conditions may result in element failure. 3 =
The element temperature is approaching, but has not reached, the low
temperature CRITICAL threshold. Continued operation under these conditions
may result in a CRITICAL condition and may reduce an element’s MTBF. 4 = The
element temperature has reached the low temperature CRITICAL threshold.
Continued operation under these conditions may result in element failure. The
actual temperature threshold values can be found in the HSV element manager
GUI.
3423
88030d5f
6
d
5f
Storage Cell: %1 Event Code: %2 Description: The average temperature of two
of the three temperature sensor groups (i.e., Drive Enclosure Environmental
Monitoring Unit, Disk Drives, and Power Supplies) exceeds the CRITICAL level.
The operational power supply(s) will automatically shut down after a short period
of time, thereby disabling the drive enclosure. This condition remains active until
either the problem is corrected, or the operational power supply(s) shut down,
whichever occurs first. This problem was detected by the Drive Enclosure
Environmental Monitoring Unit located in the drive enclosure identified in the
dencl_num field within the rack identified in the rack_num field. The rack_num
field will not be valid until a future release. Note that in this case the content of
the alarm_error_code.field.en field is undefined. The actual temperature
threshold values can be found in the HSV element manager GUI.
3439
88030d6f
3
d
6f
Storage Cell: %1 Event Code: %2 Description: An internal Drive Enclosure
Environmental Monitoring Unit error has occurred. This problem was detected by
the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure
identified in the dencl_num field within the rack identified in the rack_num field.
The rack_num field will not be valid until a future release. The
alarm_error_code.field.en field contains the value 1 signifying that the Drive
Enclosure Environmental Monitoring Unit is the affected element. The cause of
the improper operation is described by the content of the
alarm_error_code.field.ec field as follows: 1 = An internal Drive Enclosure
Environmental Monitoring Unit clock error has occurred. 2 = The Inter-IC (I2C)
bus is not processing data and the Drive Enclosure Environmental Monitoring
Unit is unable to monitor or report the status of the elements or enclosures. 5 = A
Backplane NVRAM error has occurred.
48
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
3441
88030d71
2
d
71
Storage Cell: %1 Event Code: %2 Description: An internal Drive Enclosure
Environmental Monitoring Unit error has occurred. This problem was detected by
the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure
identified in the dencl_num field within the rack identified in the rack_num field.
The rack_num field will not be valid until a future release. The
alarm_error_code.field.en field contains the value 1 signifying that the Drive
Enclosure Environmental Monitoring Unit is the affected element. The cause of
the improper operation is described by the content of the
alarm_error_code.field.ec field as follows: 3 = A drive enclosure power supply
was shut down. 16 = The Drive Enclosure Environmental Monitoring Unit ESI data
has been corrupted.
3442
88030d72
3
d
72
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental
Monitoring Unit is unable to collect data for the SCSI-3 Engineering Services
(SES) page. This problem was detected by the Drive Enclosure Environmental
Monitoring Unit located in the drive enclosure identified in the dencl_num field
within the rack identified in the rack_num field. The rack_num field will not be
valid until a future release. The alarm_error_code.field.en field contains the value
1 signifying that the Drive Enclosure Environmental Monitoring Unit is the
affected element.
3454
3455
88030d7e
88030d7f
3
3
d
d
7e
7f
Storage Cell: %1 Event Code: %2 Description: Invalid data was read from a
Drive Enclosure Environmental Monitoring Unit NVRAM. This problem was
detected by the Drive Enclosure Environmental Monitoring Unit located in the
drive enclosure identified in the dencl_num field within the rack identified in the
rack_num field. The rack_num field will not be valid until a future release. The
alarm_error_code.field.en field contains the value 1 signifying that the Drive
Enclosure Environmental Monitoring Unit is the affected element.
Storage Cell: %1 Event Code: %2 Description: An internal Drive Enclosure
Environmental Monitoring Unit error has occurred. This problem was detected by
the Drive Enclosure Environmental Monitoring Unit located in the drive enclosure
identified in the dencl_num field within the rack identified in the rack_num field.
The rack_num field will not be valid until a future release. The
alarm_error_code.field.en field contains the value 1 signifying that the Drive
Enclosure Environmental Monitoring Unit is the affected element. The cause of
the improper operation is described by the content of the
alarm_error_code.field.ec field as follows: 11 = The Drive Enclosure
Environmental Monitoring Unit cannot write data to the NVRAM. 12 = The Drive
Enclosure Environmental Monitoring Unit cannot read data from the NVRAM. 13
= The Field Programmable Gate Array (FPGA) that controls the ESI bus failed to
load information required for Drive Enclosure Environmental Monitoring Unit
operation.
3458
88030d82
3
d
82
Storage Cell: %1 Event Code: %2 Description: A drive enclosure’s address is
incorrect or the enclosure has no address. This problem was detected by the
Drive Enclosure Environmental Monitoring Unit located in the drive enclosure
identified in the dencl_num field within the rack identified in the rack_num field.
The rack_num field will not be valid until a future release. The
alarm_error_code.field.en field contains the value 1 signifying that the Drive
Enclosure Environmental Monitoring Unit is the affected element.
Storage Management Appliance Software Event Code Definitions Application Notes
49
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
3459
3461
3469
88030d83
88030d85
88030d8d
6
d
83
85
8d
Storage Cell: %1 Event Code: %2 Description: A Drive Enclosure Environmental
Monitoring Unit has experienced a hardware failure. This problem was detected
by the Drive Enclosure Environmental Monitoring Unit located in the drive
enclosure identified in the dencl_num field within the rack identified in the
rack_num field. The rack_num field will not be valid until a future release. The
alarm_error_code.field.en field contains the value 1 signifying that the Drive
Enclosure Environmental Monitoring Unit is the affected element.
3
6
d
d
Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply
failed to respond to a shut down command. This problem was detected by the
Drive Enclosure Environmental Monitoring Unit located in the drive enclosure
identified in the dencl_num field within the rack identified in the rack_num field.
The rack_num field will not be valid until a future release. The
alarm_error_code.field.en field contains the value 1 signifying that the Drive
Enclosure Environmental Monitoring Unit is the affected element.
Storage Cell: %1 Event Code: %2 Description: A drive enclosure transceiver
error has been detected. This problem was detected by the Drive Enclosure
Environmental Monitoring Unit located in the drive enclosure identified in the
dencl_num field within the rack identified in the rack_num field. The rack_num
field will not be valid until a future release. The location of the transceiver (1
through 4) is identified in the alarm_error_code.field.en field as follows: 1 =
Transceiver 01 2 = Transceiver 02 3 = Transceiver 03 4 = Transceiver 04 The
transceiver error condition is described by the content of the
alarm_error_code.field.ec field as follows: 1 = The transceivers on this link are
not the same type or they are incompatible with the drive enclosure I/O module.
This error prevents the controller from establishing a link with the enclosure drives
and eliminates the enclosure dual-loop capability. 2 = The transceiver can no
longer detect a data signal. This error prevents the controller from transferring
data on a loop and eliminates the enclosure dual-loop capability. 3 = The
system has detected an FC-AL bus fault involving a transceiver. This error prevents
the controller from transferring data on a loop and eliminates the enclosure
dual-loop capability.
3489
88030da1
6
d
a1
Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply
voltage sensor out of range condition has been reported. This problem was
detected by the Drive Enclosure Environmental Monitoring Unit located in the
drive enclosure identified in the dencl_num field within the rack identified in the
rack_num field. The rack_num field will not be valid until a future release. The
location of the voltage sensor (1 through 4) is identified in the
alarm_error_code.field.en field as follows: 1 = Power Supply 1 +5 VDC 2 =
Power Supply 1 +12 VDC 3 = Power Supply 2 +5 VDC 4 = Power Supply 2 +12
VDC The voltage sensor out of range condition is described by the content of the
alarm_error_code.field.ec field as follows: 1 = The element voltage is
approaching, but has not reached, the high voltage CRITICAL threshold.
Continued operation under these conditions may result in a CRITICAL condition.
2 = The element voltage is above the high voltage CRITICAL threshold. 3 = The
element voltage is approaching, but h as not reached, the low voltage CRITICAL
threshold. Continued operation under these conditions may result in a CRITICAL
condition. 4 = The element voltage has reached the low voltage CRITICAL
threshold.
50
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
3509
88030db5
6
d
b5
Storage Cell: %1 Event Code: %2 Description: A drive enclosure power supply
current sensor out of range condition has been reported. This problem was
detected by the Drive Enclosure Environmental Monitoring Unit located in the
drive enclosure identified in the dencl_num field within the rack identified in the
rack_num field. The rack_num field will not be valid until a future release. The
location of the current sensor (1 through 4) is identified in the
alarm_error_code.field.en field as follows: 1 = Power Supply 1 +5 VDC 2 =
Power Supply 1 +12 VDC 3 = Power Supply 2 +5 VDC 4 = Power Supply 2 +12
VDC The current sensor out of range condition is described by the content of the
alarm_error_code.field.ec field as follows: 1 = The element current is
approaching, but has not reached, the high current CRITICAL threshold.
Continued operation under these conditions may result in a CRITICAL condition.
2 = The element current is above the high current CRITICAL threshold.
3544
3545
88030dd8
88030dd9
3
6
d
d
d8
d9
Storage Cell: %1 Event Code: %2 Description: A drive enclosure backplane
invalid NVRAM read error has occurred. This problem was detected by the Drive
Enclosure Environmental Monitoring Unit located in the drive enclosure identified
in the dencl_num field within the rack identified in the rack_num field. The
rack_num field will not be valid until a future release. The
alarm_error_code.field.en field contains the value 1 signifying that the drive
enclosure is the affected element.
Storage Cell: %1 Event Code: %2 Description: A drive enclosure backplane
error has occurred. This problem was detected by the Drive Enclosure
Environmental Monitoring Unit located in the drive enclosure identified in the
dencl_num field within the rack identified in the rack_num field. The rack_num
field will not be valid until a future release. The alarm_error_code.field.en field
contains the value 1 signifying that the drive enclosure is the affected element.
The cause of the improper operation is described by the content of the
alarm_error_code.field.ec field as follows: 11 = Unable to write data to the
NVRAM. This problem prevents communication between elements in the
enclosure. 12 = Unable to read data from the NVRAM. This problem prevents
communication between elements in the enclosure. 13 = NVRAM has not been
initialized properly. This is a manufacturing error.
3549
88030ddd
6
d
dd
Storage Cell: %1 Event Code: %2 Description: A drive enclosure I/O module
error has occurred. This problem was detected by the Drive Enclosure
Environmental Monitoring Unit located in the drive enclosure identified in the
dencl_num field within the rack identified in the rack_num field. The rack_num
field will not be valid until a future release. The location of the I/O module (A
(01) and B (02)) is identified in the alarm_error_code.field.en field. The cause of
the improper operation is described by the content of the
alarm_error_code.field.ec field as follows: 1 = The I/O module’s Fibre Channel
link speed is not supported by the backplane. This error prevents the controller
from establishing a link with enclosure drives and eliminates the enclosure
dual-loop capability. 11 = Unable to write data to the I/O module NVRAM. 12
= Unable to read data from the I/O module NVRAM.
3550
88030dde
3
d
de
Storage Cell: %1 Event Code: %2 Description: A drive enclosure I/O module is
unable to communicate with the Drive Enclosure Environmental Monitoring Unit.
This problem was detected by the Drive Enclosure Environmental Monitoring Unit
located in the drive enclosure identified in the dencl_num field within the rack
identified in the rack_num field. The rack_num field will not be valid until a future
release. The location of the I/O module (A (01) and B (02)) is identified in the
alarm_error_code.field.en field.
Storage Management Appliance Software Event Code Definitions Application Notes
51
HSV Element Manager Event Codes
Table 8: HSV Element Manager Event Codes: Controller Events (Continued)
Event
ID
Event
Code
Sev- SWC
Evt.
No.
erity
ID
Description
3564
88030dec
3
d
ec
Storage Cell: %1 Event Code: %2 Description: A drive enclosure I/O module
invalid NVRAM read error has occurred. This problem was detected by the Drive
Enclosure Environmental Monitoring Unit located in the drive enclosure identified
in the dencl_num field within the rack identified in the rack_num field. The
rack_num field will not be valid until a future release. The location of the I/O
module (A (01) or B (02)) is identified in the alarm_error_code.field.en field.
3568
88030df0
2
d
f0
Storage Cell: %1 Event Code: %2 Description: The status has changed on one or
more of the drive enclosures. This is an informational event triggered by the
occurrence of a change in the status of a drive enclosure. The content of the
alarm_error_code field, drive enclosure, and rack number have no meaning for
this event.
16896 88034200
16897 88034201
16899 88034203
2
2
2
42
42
42
0
1
3
Storage Cell: %1 Event Code: %2 Description: Indicated Host Fibre Channel
port transitioned to link down.
Storage Cell: %1 Event Code: %2 Description: Indicated Host Fibre Channel
port transitioned to link failed.
Storage Cell: %1 Event Code: %2 Description: An excessive number of link
errors were detected on a Fibre Channel port. The error counters are checked
every hour. This is an informational event that reports all link status errors
detected by the Tachyon chip, triggered by an excessive number detected in one
category.
16900 88034204
3
6
42
83
4
0
Storage Cell: %1 Event Code: %2 Description: A Fibre Channel port on the
HSV110 controller has failed to respond. The evt_peq.peb field contains port
event information. The evt_peq.peq_frz_prod_index field contains the index to
the port event block that points to when the Tachyon chip entered the frozen state.
The evt_peq.peq_prod_index field contains the index to the next port event block.
The evt_peq.peq_cons_index field contains the index to the next port event block
to be acted upon.
33536
88038300
Storage Cell: %1 Event Code: %2 Description: A failure was detected during the
execution of this HSV110 controller’s on board diagnostics.
52
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Management Agent Events
Table 9 shows events generated by the HSV Management Agent, which are logged in the
Storage Management Appliance Event Log. The Event Number (Evt. No.) codes can be used
to correlate events recorded in the Management Agent Event Log of the HSV Element
Manager with the events logged in the Storage Management Appliance Event Log.
Table 9: HSV Element Manager Event Codes: Management Agent Events
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
20000 88034e20
3
0
Storage Cell: %1 Unhandled Management event generated. Event Code: %2
Description: %3
20001 88034e21
20002 88034e22
20003 88034e23
20004 88034e24
2
2
2
6
1
2
3
4
Storage Cell: %1 SCMI Object Already Exists Event Code: %2 Description: %3
Storage Cell: %1 SCMI Supplied Buffer Too Small Event Code: %2 Description: %3
Storage Cell: %1 SCMI Object Already Assigned Event Code: %2 Description: %3
Storage Cell: %1 SCMI Insufficient Available Data Storage Event Code: %2
Description: %3
20005 88034e25
20006 88034e26
3
2
5
6
Storage Cell: %1 SCMI Internal Error Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid Cell Status for Logical Disk Event Code: %2 Description:
%3
20007 88034e27
20008 88034e28
20009 88034e29
2
2
2
7
8
9
Storage Cell: %1 SCMI Invalid Class Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid Function Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid Logical Disk Block State Event Code: %2 Description:
%3
20010 88034e2a
20011 88034e2b
20012 88034e2c
20013 88034e2d
20014 88034e2e
20015 88034e2f
20016 88034e30
20017 88034e31
20018 88034e32
20019 88034e33
20020 88034e34
20021 88034e35
20022 88034e36
20023 88034e37
20024 88034e38
20025 88034e39
20026 88034e3a
2
2
2
2
2
2
2
2
3
3
2
2
2
2
2
2
2
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Storage Cell: %1 SCMI Invalid Loop Configuration Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid Parameter Event Code: %2 Description: %3
Storage Cell: %1 SCmi Invalid Parameter handle Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid Parameter Id Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid Quorum Configuration Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid Target Handle Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid Target Id Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid Time Event Code: %2 Description: %3
Storage Cell: %1 SCMI Media is Inaccessible Event Code: %2 Description: %3
Storage Cell: %1 SCMI No Fibre Channel Port Event Code: %2 Description: %3
Storage Cell: %1 SCMI No Image Event Code: %2 Description: %3
Storage Cell: %1 SCMI No Permission Event Code: %2 Description: %3
Storage Cell: %1 SCMI Storage system not initialized Event Code: %2 Description: %3
Storage Cell: %1 SCMI Not a Loop Port Event Code: %2 Description: %3
Storage Cell: %1 SCMI Not a Participating Controller Event Code: %2 Description: %3
Storage Cell: %1 SCMI Object is in Use Event Code: %2 Description: %3
Storage Cell: %1 SCMI Parameter Object Does Not Exist Event Code: %2 Description:
%3
20027 88034e3b
20028 88034e3c
20029 88034e3d
20030 88034e3e
2
2
2
2
27
28
29
30
Storage Cell: %1 SCMI Target Object Does Not Exist Event Code: %2 Description: %3
Storage Cell: %1 SCMI Timeout Event Code: %2 Description: %3
Storage Cell: %1 SCMI Unknown Id Event Code: %2 Description: %3
Storage Cell: %1 SCMI Unknown Parameter Handle Event Code: %2 Description: %3
Storage Management Appliance Software Event Code Definitions Application Notes
53
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
20031 88034e3f
20032 88034e40
20033 88034e41
20034 88034e42
20035 88034e43
20036 88034e44
20037 88034e45
20038 88034e46
20039 88034e47
20040 88034e48
20041 88034e49
2
2
3
3
2
2
2
2
2
2
2
31
32
33
34
35
36
37
38
39
40
41
Storage Cell: %1 SCMI Unrecoverable Media Error Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid State Event Code: %2 Description: %3
Storage Cell: %1 SCMI Transport Error Event Code: %2 Description: %3
Storage Cell: %1 SCMI Volume is Missing Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid Cursor Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid Target Logical Disk Event Code: %2 Description: %3
Storage Cell: %1 SCMI No More Events Event Code: %2 Description: %3
Storage Cell: %1 SCMI Lock Busy Event Code: %2 Description: %3
Storage Cell: %1 SCMI Time Not Set Event Code: %2 Description: %3
Storage Cell: %1 SCMI Not a Supported Version Event Code: %2 Description: %3
Storage Cell: %1 SCMI No Logical Disk for StorageCell Virtual Disk Event Code: %2
Description: %3
20042 88034e4a
20043 88034e4b
20044 88034e4c
20045 88034e4d
20046 88034e4e
20047 88034e4f
20048 88034e50
2
3
2
2
2
2
2
42
43
44
45
46
47
48
Storage Cell: %1 SCMI Logical disk Presented Event Code: %2 Description: %3
Storage Cell: %1 SCMI Operation Denied On Slave Event Code: %2 Description: %3
Storage Cell: %1 SCMI Not DRM Licensed Event Code: %2 Description: %3
Storage Cell: %1 SCMI Not DRM Member Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid DRM Mode Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid DRM State Event Code: %2 Description: %3
Storage Cell: %1 Security credentials needed. Please update your system’s ID and
password in the Storage System Access menu. Event Code: %2 Description: %3
20049 88034e51
2
49
Storage Cell: %1 Security credentials supplied were invalid. Please update your system’s
ID and password in the Storage System Access menu. Event Code: %2 Description: %3
20050 88034e52
20051 88034e53
20052 88034e54
20053 88034e55
20054 88034e56
20055 88034e57
20056 88034e58
2
3
2
2
2
2
2
50
51
52
53
54
55
56
Storage Cell: %1 SCMI Already Logged In Event Code: %2 Description: %3
Storage Cell: %1 SCMI Cell Connection Down Event Code: %2 Description: %3
Storage Cell: %1 SCMI DRM Group Empty Event Code: %2 Description: %3
Storage Cell: %1 SCMI Incompatible Attribute Event Code: %2 Description: %3
Storage Cell: %1 SCMI Is Drm Member Event Code: %2 Description: %3
Storage Cell: %1 SCMI Is Log Unit Event Code: %2 Description: %3
Storage Cell: %1 SCMI No Destination DRM Group Specified Event Code: %2
Description: %3
20057 88034e59
20058 88034e5a
20059 88034e5b
20060 88034e5c
20061 88034e5d
20062 88034e5e
20063 88034e5f
20064 88034e60
20065 88034e61
20066 88034e62
20067 88034e63
2
3
2
2
2
2
2
2
2
2
2
57
58
59
60
61
62
63
64
65
66
67
Storage Cell: %1 SCMI Not Presented Event Code: %2 Description: %3
Storage Cell: %1 SCMI Other Nsc Failed Event Code: %2 Description: %3
Storage Cell: %1 SCMI Max Objects Event Code: %2 Description: %3
Storage Cell: %1 SCMI Max Size Event Code: %2 Description: %3
Storage Cell: %1 SCMI Password Mismatch Event Code: %2 Description: %3
Storage Cell: %1 SCMI Is Merging Event Code: %2 Description: %3
Storage Cell: %1 SCMI Is Logging Event Code: %2 Description: %3
Storage Cell: %1 SCMI Is Suspended Event Code: %2 Description: %3
Storage Cell: %1 SCMI Bad Image Header Event Code: %2 Description: %3
Storage Cell: %1 SCMI Bad Image Event Code: %2 Description: %3
Storage Cell: %1 SCMI Image Too Large Event Code: %2 Description: %3
54
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
20068 88034e64
20069 88034e65
20070 88034e66
20071 88034e67
20072 88034e68
20073 88034e69
2
2
2
2
2
2
2
2
2
6
2
2
68
69
70
71
72
73
74
75
76
77
78
79
Storage Cell: %1 SCMI EMU Not Available Event Code: %2 Description: %3
Storage Cell: %1 SCMI EMU Indefinite Delay Event Code: %2 Description: %3
Storage Cell: %1 SCMI Image Incompatible Event Code: %2 Description: %3
Storage Cell: %1 SCMI Bad Image Segment Event Code: %2 Description: %3
Storage Cell: %1 SCMI Image Already Loaded Event Code: %2 Description: %3
Storage Cell: %1 SCMI Image Write Error Event Code: %2 Description: %3
Storage Cell: %1 SCMI Logical Disk Sharing Event Code: %2 Description: %3
Storage Cell: %1 SCMI Bad Image Size Event Code: %2 Description: %3
Storage Cell: %1 SCMI Image Load Busy Event Code: %2 Description: %3
Storage Cell: %1 SCMI Volume Failure Predicted Event Code: %2 Description: %3
Storage Cell: %1 SCMI Invalid Object Condition Event Code: %2 Description: %3
20074
20075
20076
88034e6a
88034e6b
88034e6c
20077 88034e6d
20078 88034e6e
20079 88034e6f
Storage Cell: %1 SCMI Invalid Predecessor Virtual Disk Condition Event Code: %2
Description: %3
20080 88034e70
20081 88034e71
2
2
80
81
Storage Cell: %1 SCMI Invalid Volume Usage Event Code: %2 Description: %3
Storage Cell: %1 SCMI Minimum Volumes In Disk Group Event Code: %2 Description:
%3
20082 88034e72
20083 88034e73
20084 88034e74
20085 88034e75
20086 88034e76
20087 88034e77
2
2
2
2
2
3
82
83
84
85
86
87
Storage Cell: %1 SCMI Shutdown In Progress Event Code: %2 Description: %3
Storage Cell: %1 SCMI Not Ready Event Code: %2 Description: %3
Storage Cell: %1 SCMI Is Snapshot Event Code: %2 Description: %3
Storage Cell: %1 SCMI Incompatible Mirror Policy Event Code: %2 Description: %3
Storage Cell: %1 SCMI Inoperative Event Code: %2 Description: %3
Storage Cell: %1 SCMI Disk group inoperative or less than 8 disks in group Event
Code: %2 Description: %3
20088 88034e78
20089 88034e79
20090 88034e7a
20091 88034e7b
6
2
3
2
88
89
90
91
Storage Cell: %1 SCMI StorageCell Inoperative Event Code: %2 Description: %3
Storage Cell: %1 SCMI Failsafe Locked Event Code: %2 Description: %3
Storage Cell: %1 SCMI Data Flush Incomplete Event Code: %2 Description: %3
Storage Cell: %1 SCMI Redundancy Mirrored Inoperative Event Code: %2 Description:
%3
20092 88034e7c
20093 88034e7d
20094 88034e7e
20095 88034e7f
20096 88034e80
20097 88034e81
20098 88034e82
20099 88034e83
20100 88034e84
2
3
2
2
6
6
2
2
2
92
93
94
Storage Cell: %1 SCMI Duplicate LUN Event Code: %2 Description: %3
Storage Cell: %1 SCMI Other Remote NSC Failed Event Code: %2 Description: %3
Storage Cell: %1 SCMI Unknown Remote Unit Event Code: %2 Description: %3
Storage Cell: %1 SCMI Unknown Remote DRM Group Event Code: %2 Description: %3
Storage Cell: %1 SCMI PLDMC Failed Event Code: %2 Description: %3
Storage Cell: %1 SCMI Lock Failed Event Code: %2 Description: %3
95
96
97
98
99
100
Storage Cell: %1 SCMI Remote SCS Error Event Code: %2 Description: %3
Storage Cell: %1 Scmi Cell Connection Up Event Code: %2 Description: %3
Storage Cell: %1 Scmi Login Needed - Password Changed Event Code: %2
Description: %3
20101 88034e85
20102 88034e86
20103 88034e87
2
2
2
101
102
103
Storage Cell: %1 Scmi Max Logins Reached Event Code: %2 Description: %3
Storage Cell: %1 Scmi Invalid Cookie Event Code: %2 Description: %3
Storage Cell: %1 Scmi Login Timed Out Event Code: %2 Description: %3
Storage Management Appliance Software Event Code Definitions Application Notes
55
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
20104 88034e88
20105 88034e89
20106 88034e8a
20107 88034e8b
20108 88034e8c
20109 88034e8d
20110 88034e8e
20111 88034e8f
20112 88034e90
20113 88034e91
20114 88034e92
20115 88034e93
20116 88034e94
21000 88035208
21001 88035209
21002 8803520a
2
2
2
2
2
2
2
2
2
2
2
2
2
2
6
3
104
105
106
107
Storage Cell: %1 Scmi Max Snapshot Depth Reached Event Code: %2 Description: %3
Storage Cell: %1 Scmi Attribute Mismatch Event Code: %2 Description: %3
Storage Cell: %1 Scmi Password Not Set Event Code: %2 Description: %3
Storage Cell: %1 Scmi Not Host Port Event Code: %2 Description: %3
Storage Cell: %1 Scmi Duplicate Lun WWID Event Code: %2 Description: %3
Storage Cell: %1 Scmi System Inoperative Event Code: %2 Description: %3
Storage Cell: %1 Scmi SnapClone Active Event Code: %2 Description: %3
Storage Cell: %1 Scmi Emu Load Busy Event Code: %2 Description: %3
Storage Cell: %1 Scmi Duplicate User Name Event Code: %2 Description: %3
Storage Cell: %1 Scmi Drive Reserved For Code Load Event Code: %2 Description: %3
Storage Cell: %1 Scmi Already Presented Event Code: %2 Description: %3
Storage Cell: %1 Scmi Invalid Remote Scell Event Code: %2 Description: %3
Storage Cell: %1 Scmi No Scmi Lock Event Code: %2 Description: %3
Storage Cell: %1 Logical Disk Condition Change Event Code: %2 Description: %3
Storage Cell: %1 Storage system is FULL **critical** Event Code: %2 Description: %3
108
109
110
111
112
113
114
115
116
1000
1001
1002
Storage Cell: %1 Storage system is almost FULL. Disk group at or above maximum
capacity warning level. Event Code: %2 Description: %3
21003 8803520b
2
1003
Storage Cell: %1 NSC Cache Battery Condition Change Event Code: %2 Description:
%3
21004 8803520c
21005 8803520d
21006 8803520e
21007 8803520f
21008 88035210
21009 88035211
21010 88035212
21011 88035213
21012 88035214
2
2
2
2
2
2
2
2
2
1004
1005
1006
1007
1008
1009
1010
1011
1012
Storage Cell: %1 NSC Cache Condition Change Event Code: %2 Description: %3
Storage Cell: %1 NSC Condition Change Event Code: %2 Description: %3
Storage Cell: %1 NSC FC Port Condition Change Event Code: %2 Description: %3
Storage Cell: %1 Physical Device Condition Change Event Code: %2 Description: %3
Storage Cell: %1 Physical Store Condition Change Event Code: %2 Description: %3
Storage Cell: %1 Host condition change Event Code: %2 Description: %3
Storage Cell: %1 Storage system time has been set Event Code: %2 Description: %3
Storage Cell: %1 Volume Condition change Event Code: %2 Description: %3
Storage Cell: %1 Volume insufficient_resources condition change Event Code: %2
Description: %3
21013 88035215
21014 88035216
2
2
1013
1014
Storage Cell: %1 Volume Quorum Disk change Event Code: %2 Description: %3
Storage Cell: %1 The state of an object in the system has changed. View adjacent events
for more detail. Event Code: %2 Description: %3
22001 880355f1
22002 880355f2
6
2
2001
2002
Storage Cell: %1 Startup Failed Event Code: %2 Description: %3
Storage Cell: %1 Management agent event log cleared successfully Event Code: %2
Description: %3
22003 880355f3
3
2003
Storage Cell: %1 Invalid name specified for storage system Event Code: %2
Description: %3
22004 880355f4
22005 880355f5
2
3
2004
2005
Storage Cell: %1 Storage system is not initialized Event Code: %2 Description: %3
Storage Cell: %1 Duplicate name for virtual disk found Event Code: %2 Description:
%3
22006 880355f6
3
2006
Storage Cell: %1 Invalid name specified for virtual disk Event Code: %2 Description:
%3
56
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
22007 880355f7
3
2007
Storage Cell: %1 Virtual disk name exceeds maximum length Event Code: %2
Description: %3
22008 880355f8
3
2008
Storage Cell: %1 Invalid parameter specified for virtual disk Event Code: %2
Description: %3
22009 880355f9
22010 880355fa
3
3
2009
2010
Storage Cell: %1 No virtual disk found Event Code: %2 Description: %3
Storage Cell: %1 Specified virtual disk size exceeds available size Event Code: %2
Description: %3
22011 880355fb
22012 880355fc
22013 880355fd
22014 880355fe
22015 880355ff
22016 88035600
22017 88035601
22018 88035602
22019 88035603
22020 88035604
22021 88035605
22022 88035606
2
3
3
3
3
3
3
3
3
3
3
3
2011
2012
2013
2014
2015
2016
2017
2018
2019
2020
2021
2022
Storage Cell: %1 There are not enough disk drives to create a disk group Event Code:
%2 Description: %3
Storage Cell: %1 Specified number of device exceeds available number of disk Event
Code: %2 Description: %3
Storage Cell: %1 Specified number of device is below the minimum number of disk to
create a disk group (minimum 8) Event Code: %2 Description: %3
Storage Cell: %1 No available volumes to complete the request Event Code: %2
Description: %3
Storage Cell: %1 Specified spare count exceeds maximum count Event Code: %2
Description: %3
Storage Cell: %1 Completed unpresenting virutal disk to host Event Code: %2
Description: %3
Storage Cell: %1 Negative value for device count is invalid Event Code: %2
Description: %3
Storage Cell: %1 Specified spare count is below minimum count Event Code: %2
Description: %3
Storage Cell: %1 Specified device count is below minimum count Event Code: %2
Description: %3
Storage Cell: %1 Requested device count exceeds available physical store Event Code:
%2 Description: %3
Storage Cell: %1 Invalid refresh interval value. Should be numeric and non-negative.
Event Code: %2 Description: %3
Storage Cell: %1 Invalid security message. Should not be blank. Event Code: %2
Description: %3
22023 88035607
22024 88035608
22025 88035609
2
2
2
2023
2024
2025
Storage Cell: %1 Virtual Disk Create Complete Event Code: %2 Description: %3
Storage Cell: %1 Storage system uninitialized Event Code: %2 Description: %3
Storage Cell: %1 Storage system successfully initialized Event Code: %2 Description:
%3
22026 8803560a
22027 8803560b
22028 8803560c
22029 8803560d
22030 8803560e
22031 8803560f
22032 88035610
2
2
2
2
2
2
2
2026
2027
2028
2029
2030
2031
2032
Storage Cell: %1 Device Added Successfully Event Code: %2 Description: %3
Storage Cell: %1 Storage system successfully renamed Event Code: %2 Description: %3
Storage Cell: %1 Virtual Disk Delete Complete Event Code: %2 Description: %3
Storage Cell: %1 Virtual Disk Renamed - Complete Event Code: %2 Description: %3
Storage Cell: %1 Refresh Interval Changed Event Code: %2 Description: %3
Storage Cell: %1 Security Message Changed Event Code: %2 Description: %3
Storage Cell: %1 Present Virtual Disk to a Host - Complete Event Code: %2
Description: %3
22033 88035611
2
2033
Storage Cell: %1 Control Startup Complete Event Code: %2 Description: %3
Storage Management Appliance Software Event Code Definitions Application Notes
57
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
22034 88035612
22035 88035613
22036 88035614
22037 88035615
22038 88035616
22039 88035617
2
2
2
2
6
2
2034
2035
2036
2037
2038
2039
Storage Cell: %1 Change Device Usage Complete Event Code: %2 Description: %3
Storage Cell: %1 Control Shutdown - Complete Event Code: %2 Description: %3
Storage Cell: %1 Nsc Shutdown - Complete Event Code: %2 Description: %3
Storage Cell: %1 Nsc Crash - Complete Event Code: %2 Description: %3
Storage Cell: %1 Control Memory Allocation Failure Event Code: %2 Description: %3
Storage Cell: %1 There must be at least 5 member devices to create Raid 5 VD Event
Code: %2 Description: %3
22040 88035618
2
2040
Storage Cell: %1 Access level denied or session activity timeout. Please log in again.
Event Code: %2 Description: %3
22041 88035619
22042 8803561a
22043 8803561b
22044 8803561c
22045 8803561d
22046 8803561e
22047 8803561f
22048 88035620
22049 88035621
22050 88035622
2
2
2
2
2
6
2
2
2
2
2041
2042
2043
2044
2045
2046
2047
2048
2049
2050
Storage Cell: %1 Virtual Disk Snapshot - Completed Event Code: %2 Description: %3
Storage Cell: %1 Virtual Disk Snapclone - Completed Event Code: %2 Description: %3
Storage Cell: %1 Virtual Disk Snapshot - Failed Event Code: %2 Description: %3
Storage Cell: %1 Virtual Disk Snapclone - Failed Event Code: %2 Description: %3
Storage Cell: %1 Restore Device - Completed Event Code: %2 Description: %3
Storage Cell: %1 Device Failed Event Code: %2 Description: %3
Storage Cell: %1 Host record added successfully Event Code: %2 Description: %3
Storage Cell: %1 Nsa object discarded successfully Event Code: %2 Description: %3
Storage Cell: %1 Invalid host adapter ID Event Code: %2 Description: %3
Storage Cell: %1 Specified device is already a member of the system Event Code: %2
Description: %3
22051 88035623
22052 88035624
2
2
2051
2052
Storage Cell: %1 Create Folder - Completed Event Code: %2 Description: %3
Storage Cell: %1 Change Object Properties - Completed Event Code: %2 Description:
%3
22053 88035625
22057 88035629
22058 8803562a
22059 8803562b
22060 8803562c
22061 8803562d
2
2
2
2
2
2
2053
2057
2058
2059
2060
2061
Storage Cell: %1 Comments exceed maximum size Event Code: %2 Description: %3
Storage Cell: %1 Completed disk group creation Event Code: %2 Description: %3
Storage Cell: %1 Added host port Event Code: %2 Description: %3
Storage Cell: %1 Discarded host port Event Code: %2 Description: %3
Storage Cell: %1 EMU/Shelf code load complete Event Code: %2 Description: %3
Storage Cell: %1 Operation will exceed the available capacity of the disk group Event
Code: %2 Description: %3
22062 8803562e
22063 8803562f
2
2
2062
2063
Storage Cell: %1 Controller(s) code load complete Event Code: %2 Description: %3
Storage Cell: %1 The target device is not in the right condition to perform the operation
Event Code: %2 Description: %3
22064 88035630
22065 88035631
2
2
2064
2065
Storage Cell: %1 Storage system Device Addition Policy changed successfully Event
Code: %2 Description: %3
Storage Cell: %1 Maximum number of disk groups exceeded Event Code: %2
Description: %3
22066 88035632
22067 88035633
3
3
2066
2067
Storage Cell: %1 Nsa object discard failed. Event Code: %2 Description: %3
Storage Cell: %1 There are not enough disks to meet the minimum number requirement
Event Code: %2 Description: %3
22068 88035634
2
2068
Storage Cell: %1 Entry added successfully in the password file Event Code: %2
Description: %3
58
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
22069 88035635
22070 88035636
22071 88035637
2
2
2
2
2
2
2
2
2
2069
2070
2071
2072
2073
2074
2075
2076
2077
Storage Cell: %1 Entry updated successfully in the password file Event Code: %2
Description: %3
Storage Cell: %1 Entry discarded successfully in the password file Event Code: %2
Description: %3
Storage Cell: %1 Storage system is in an unknown state. Communications error or
unresponsive controller. Event Code: %2 Description: %3
22072
22073
22074
22075
22076
88035638
88035639
8803563a
8803563b
8803563c
Storage Cell: %1 Object not found. Operation on this object is completed Event Code:
%2 Description: %3
Storage Cell: %1 There is no more available space to create a virtual disk Event Code:
%2 Description: %3
Storage Cell: %1 Name or comments contains invalid characters Event Code: %2
Description: %3
Storage Cell: %1 Duplicate - Another object with the same name is found Event Code:
%2 Description: %3
Storage Cell: %1 Error - No healthy disk group(s) to create a unit. Resolve any abnormal
conditions in the disk group first. Event Code: %2 Description: %3
22077 8803563d
Storage Cell: %1 Error - Operating System ID must be a valid number. Event Code: %2
Description: %3
22078
22079
8803563e
8803563f
2
2
3
2
2078
2079
2080
2081
Storage Cell: %1 Watchdog successfully started Event Code: %2 Description: %3
Storage Cell: %1 Watchdog successfully stopped Event Code: %2 Description: %3
Storage Cell: %1 Delete Event Config List failed Event Code: %2 Description: %3
22080 88035640
22081 88035641
Storage Cell: %1 Disk group meltdown repaired successfully. Event Code: %2
Description: %3
22082 88035642
22083 88035643
22084 88035644
22085 88035645
22086 88035646
22087 88035647
22088 88035648
22089 88035649
22090 8803564a
22091 8803564b
2
2
2
2
2
2
2
2
2
2
2082
2083
2084
2085
2086
2087
2088
2089
2090
2091
Storage Cell: %1 There are no available LUNs to present this unit. Event Code: %2
Description: %3
Storage Cell: %1 Controller time synchronization turned on. Event Code: %2
Description: %3
Storage Cell: %1 Controller time synchronization turned off. Event Code: %2
Description: %3
Storage Cell: %1 System login failed. Invalid password. Event Code: %2 Description:
%3
Storage Cell: %1 System is not set for password validation. Event Code: %2
Description: %3
Storage Cell: %1 Agent is already logged in to this system. Event Code: %2
Description: %3
Storage Cell: %1 StorageCell time set to custom time. Controller time syncronization
automatically turned off. Event Code: %2 Description: %3
Storage Cell: %1 StorageCell time set to SAN appliance time. Event Code: %2
Description: %3
Storage Cell: %1 StorageCell time set to browser time. Controller time syncronization
automatically turned off. Event Code: %2 Description: %3
Storage Cell: %1 StorageCell time set to controller time. Controller time syncronization
automatically turned off. Event Code: %2 Description: %3
23001 880359d9
23002 880359da
2
2
3001
3002
Storage Cell: %1 Event Manager Offline Event Code: %2 Description: %3
Storage Cell: %1 Event Manager Online Event Code: %2 Description: %3
Storage Management Appliance Software Event Code Definitions Application Notes
59
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
23003 880359db
23004 880359dc
23005 880359dd
23006 880359de
23007 880359df
6
2
3
3
2
3003
3004
3005
3006
3007
Storage Cell: %1 Event Manager - Startup Failed Event Code: %2 Description: %3
Storage Cell: %1 Event Manager - Startup Complete Event Code: %2 Description: %3
Storage Cell: %1 Event Manager - Abnormal Startup Event Code: %2 Description: %3
Storage Cell: %1 Event Manager - Shutdown Failed Event Code: %2 Description: %3
Storage Cell: %1 Event Manager - Shutdown Complete Event Code: %2 Description:
%3
23008 880359e0
23009 880359e1
3
3
3008
3009
Storage Cell: %1 Event Manager - Abnormal Shutdown Event Code: %2 Description:
%3
Storage Cell: %1 Unable to open NSA Local Event Log File Event Code: %2
Description: %3
23010 880359e2
23011 880359e3
3
3
3010
3011
Storage Cell: %1 Unable to open NSA Debug File Event Code: %2 Description: %3
Storage Cell: %1 EM: Agent event file on SC MLD unavailable - trying local event file.
Event Code: %2 Description: %3
23012 880359e4
23013 880359e5
3
3
3012
3013
Storage Cell: %1 Unable to open Local Temp Event File - possibly no initialized SC
Event Code: %2 Description: %3
Storage Cell: %1 Unable to clear NSA Local Event Log File Event Code: %2
Description: %3
23014 880359e6
23015 880359e7
23016 880359e8
23017 880359e9
23018 880359ea
23019 880359eb
23020 880359ec
23021 880359ed
23022 880359ee
23023 880359ef
23024 880359f0
23025 880359f1
23026 880359f2
23027 880359f3
23028 880359f4
23029 880359f5
23030 880359f6
3
3
3
3
6
2
2
2
2
2
2
2
2
2
3
2
2
3014
3015
3016
3017
3018
3019
3020
3021
3022
3023
3024
3025
3026
3027
3028
3029
3030
Storage Cell: %1 Unable to clear NSA Debug File Event Code: %2 Description: %3
Storage Cell: %1 Unable to clear NSA Event Log File Event Code: %2 Description: %3
Storage Cell: %1 Local log file found on startup Event Code: %2 Description: %3
Storage Cell: %1 Event Queue Flush Error Event Code: %2 Description: %3
Storage Cell: %1 Log Event Action Failed Event Code: %2 Description: %3
Storage Cell: %1 EM File Manager Online Event Code: %2 Description: %3
Storage Cell: %1 EM File Manager Offline Event Code: %2 Description: %3
Storage Cell: %1 EM Log Manager Online Event Code: %2 Description: %3
Storage Cell: %1 EM Log Manager Offline Event Code: %2 Description: %3
Storage Cell: %1 Startup Complete Event Code: %2 Description: %3
Storage Cell: %1 Local NSA logfile is empty Event Code: %2 Description: %3
Storage Cell: %1 Event Queue Online Event Code: %2 Description: %3
Storage Cell: %1 Event Queue Offline Event Code: %2 Description: %3
Storage Cell: %1 Event Queue is full Event Code: %2 Description: %3
Storage Cell: %1 Status Descriptions Unavailable Event Code: %2 Description: %3
Storage Cell: %1 EM Description Mngr Online Event Code: %2 Description: %3
Storage Cell: %1 EM: User Defined Status Description File Initialized Event Code: %2
Description: %3
23031 880359f7
23032 880359f8
23033 880359f9
23034 880359fa
23035 880359fb
23036 880359fc
3
3
3
3
3
6
3031
3032
3033
3034
3035
3036
Storage Cell: %1 EM Description Mngr Start Failed Event Code: %2 Description: %3
Storage Cell: %1 EM Log Mngr Start Failed Event Code: %2 Description: %3
Storage Cell: %1 EM File Mngr Start Failed Event Code: %2 Description: %3
Storage Cell: %1 EM Event Queue Start Failed Event Code: %2 Description: %3
Storage Cell: %1 EM: NSA log file unavailable Event Code: %2 Description: %3
Storage Cell: %1 EM Memory Allocation Error Event Code: %2 Description: %3
60
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
23037 880359fd
23038 880359fe
23039 880359ff
23040 88035a00
3
3
3
2
3037
3038
3039
3040
Storage Cell: %1 EM: Local Event Configuration File Unavailable Event Code: %2
Description: %3
Storage Cell: %1 EM: MLD Notification File Unavailable - retrieving local backup copy
Event Code: %2 Description: %3
Storage Cell: %1 EM: Local Notification Host List File Unavailable Event Code: %2
Description: %3
Storage Cell: %1 EM: SCMI returns zero SC Events but reports additional events Event
Code: %2 Description: %3
23041 88035a01
23042 88035a02
23043 88035a03
2
2
2
3041
3042
3043
Storage Cell: %1 Undefined Status Code Event Code: %2 Description: %3
Storage Cell: %1 Status Code Not Found Event Code: %2 Description: %3
Storage Cell: %1 EM Failed SC Init - couldn’t retrieve SC Event Event Code: %2
Description: %3
23044 88035a04
23045 88035a05
23046 88035a06
23047 88035a07
23048 88035a08
23049 88035a09
23050 88035a0a
23051 88035a0b
23052 88035a0c
23053 88035a0d
23054 88035a0e
23055 88035a0f
23056 88035a10
2
2
2
3
2
2
6
3
3
2
2
3
2
3044
3045
3046
3047
3048
3049
3050
3051
3052
3053
3054
3055
3056
Storage Cell: %1 Override this description with missing filename Event Code: %2
Description: %3
Storage Cell: %1 Invalid storage system event sequence number - can’t retrieve event
Event Code: %2 Description: %3
Storage Cell: %1 Invalid SC termination event sequence number - can’t retrieve event
Event Code: %2 Description: %3
Storage Cell: %1 EM: Event config file unavailable from MLD - retrieving local backup
copy Event Code: %2 Description: %3
Storage Cell: %1 EM: Local user defined event state file unavailable Event Code: %2
Description: %3
Storage Cell: %1 EM: EMU event monitoring thread unable to start Event Code: %2
Description: %3
Storage Cell: %1 EM: EMU event - this description will be overwritten Event Code: %2
Description: %3
Storage Cell: %1 EM: Failed to write Event Config file to MLD Event Code: %2
Description: %3
Storage Cell: %1 EM: Failed to write Notification Host List to MLD Event Code: %2
Description: %3
Storage Cell: %1 EM: Event Configiguration Filename Error or File empty Event Code:
%2 Description: %3
Storage Cell: %1 EM: Notification Hostlist Filename Error or File empty Event Code: %2
Description: %3
Storage Cell: %1 EM: Event Config List Object Reference Error Event Code: %2
Description: %3
Storage Cell: %1 EM: SC Parse File successfully uploaded Event Code: %2 Description:
%3
23057 88035a11
23058 88035a12
2
3
3057
3058
Storage Cell: %1 EM: SC Parse File upload failed Event Code: %2 Description: %3
Storage Cell: %1 EM: Contents of the uploaded parse file invalid - unexpected contents
Event Code: %2 Description: %3
23059 88035a13
23060 88035a14
3
6
3059
3060
Storage Cell: %1 EM: Parse file is empty Event Code: %2 Description: %3
Storage Cell: %1 Storage system being shutdown due to a command failure. Event
Code: %2 Description: %3
23061 88035a15
2
3061
Storage Cell: %1 EM: Could not retrieve a storage system event Event Code: %2
Description: %3
Storage Management Appliance Software Event Code Definitions Application Notes
61
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
23062 88035a16
23063 88035a17
2
3
3062
3063
Storage Cell: %1 EM: Init SC Event config list failed Event Code: %2 Description: %3
Storage Cell: %1 Could not initialize Comm infrastructure for event logging to system log
Event Code: %2 Description: %3
23064 88035a18
23065 88035a19
6
6
3064
3065
Storage Cell: %1 EM: Storage system pointer is NULL! Event Code: %2 Description: %3
Storage Cell: %1 EM: Failed to log event to the Appliance event log: check if log is full
Event Code: %2 Description: %3
23066 88035a1a
3
3
6
6
6
3
3
6
3
2
3
2
2
2
6
3066
3067
3068
3069
3070
3071
3072
3073
3074
3075
3076
3077
3078
3079
3080
Storage Cell: %1 EM: Description Mngr Init StorageCell Failed Event Code: %2
Description: %3
23067
88035a1b
Storage Cell: %1 EM: Description file too small. File read problem Or Incomplete file.
Event Code: %2 Description: %3
23068 88035a1c
23069 88035a1d
Storage Cell: %1 EM: Can’t init NT Event object pointer Event Code: %2 Description:
%3
Storage Cell: %1 EM: Can’t init NT Notification object pointer Event Code: %2
Description: %3
23070
88035a1e
Storage Cell: %1 EM: Appliance Event Logging Failure - log may be full Event Code:
%2 Description: %3
23071 88035a1f
Storage Cell: %1 EM: SCMI returned bad additional events number Event Code: %2
Description: %3
23072
23073
23074
23075
23076
88035a20
88035a21
88035a22
88035a23
88035a24
Storage Cell: %1 EM: SCMI returned zero sized SC Event Event Code: %2 Description:
%3
Storage Cell: %1 EM: Local event file Size exceeds max size - event logging shutdown
Event Code: %2 Description: %3
Storage Cell: %1 EM: Local event file exceeded max size limit - truncating file Event
Code: %2 Description: %3
Storage Cell: %1 EventQueue index passed is out of bounds Event Code: %2
Description: %3
Storage Cell: %1 EM: An abnormal number of duplicate events logged - dropping
duplicates Event Code: %2 Description: %3
23077 88035a25
Storage Cell: %1 EM: Update of the MLD Status Description file failed Event Code: %2
Description: %3
23078
23079
88035a26
88035a27
Storage Cell: %1 EM: NsaStatusDescriptions.txt open file error Event Code: %2
Description: %3
Storage Cell: %1 EM: NsaStatusDescriptions.txt file error - file size discrepency from mld
list Event Code: %2 Description: %3
23080 88035a28
Storage Cell: %1 SC Event Log has been cleared and restarted. Possible RAID1
Meltdown. Event Code: %2 Description: %3
23081 88035a29
23082 88035a2a
23083 88035a2b
23084 88035a2c
2
2
2
2
3081
3082
3083
3084
Storage Cell: %1 Invalid logType parameter Event Code: %2 Description: %3
Storage Cell: %1 Unsupported version Event Code: %2 Description: %3
Storage Cell: %1 Log file is empty Event Code: %2 Description: %3
Storage Cell: %1 Storage System with this WWN is not visible to this agent or the
WWN is invalid Event Code: %2 Description: %3
23085 88035a2d
23086 88035a2e
6
2
3085
3086
Storage Cell: %1 Pointer to Event Manager is NULL Event Code: %2 Description: %3
Storage Cell: %1 Parsefile for current firmware version not found. Upload correct parse
file. Event Code: %2 Description: %3
62
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
23090 88035a32
2
3090
Storage Cell: %1 The contents of this file appear to be invalid Event Code: %2
Description: %3
23091 88035a33
2
3091
Storage Cell: %1 The MIB failed to build due to a missing parse file. Event Code: %2
Description: %3
24000 88035dc0
24001 88035dc1
24002 88035dc2
24003 88035dc3
24004 88035dc4
24005 88035dc5
24006 88035dc6
24007 88035dc7
24008 88035dc8
24009 88035dc9
2
2
2
2
2
2
2
2
2
2
4000
4001
4002
4003
4004
4005
4006
4007
4008
4009
Storage Cell: %1 MLD Manager Subsystem Error Event Code: %2 Description: %3
Storage Cell: %1 MLD Manager Offline Event Code: %2 Description: %3
Storage Cell: %1 MLD Manager Online Event Code: %2 Description: %3
Storage Cell: %1 MLD Manager Startup Failed Event Code: %2 Description: %3
Storage Cell: %1 MLD Manager Startup Complete Event Code: %2 Description: %3
Storage Cell: %1 MLD Manager Abnormal Startup Event Code: %2 Description: %3
Storage Cell: %1 MLD Manager Shutdown Failed Event Code: %2 Description: %3
Storage Cell: %1 MLD Manager Shutdown Complete Event Code: %2 Description: %3
Storage Cell: %1 MLD Manager Abnormal Shutdown Event Code: %2 Description: %3
Storage Cell: %1 Unable to startup WSA during MldMgr:init Event Code: %2
Description: %3
24010 88035dca
2
4010
Storage Cell: %1 Unable to get Server Host Name during MldMgr:init Event Code: %2
Description: %3
24011 88035dcb
24012 88035dcc
2
2
4011
4012
Storage Cell: %1 Invalid Host IP Address specified Event Code: %2 Description: %3
Storage Cell: %1 Unable to open the NsaMldMgr.dat file for Write Event Code: %2
Description: %3
24013 88035dcd
2
4013
Storage Cell: %1 Unable to open the NsaMldMgr.dat file for Read Event Code: %2
Description: %3
24014 88035dce
24015 88035dcf
24016 88035dd0
24017 88035dd1
24018 88035dd2
24019 88035dd3
24020 88035dd4
24021 88035dd5
24022 88035dd6
24023 88035dd7
24024 88035dd8
24025 88035dd9
24026 88035dda
24027 88035ddb
2
2
2
2
2
2
2
2
2
2
2
2
2
2
4014
4015
4016
4017
4018
4019
4020
4021
4022
4023
4024
4025
4026
4027
Storage Cell: %1 Agent Uid does not exist Event Code: %2 Description: %3
Storage Cell: %1 Unable to find Object Event Code: %2 Description: %3
Storage Cell: %1 Unable to store Object Event Code: %2 Description: %3
Storage Cell: %1 Unable to find Object Cell Event Code: %2 Description: %3
Storage Cell: %1 Unable to create MLD Event Code: %2 Description: %3
Storage Cell: %1 lastSafeChoiceDelay Expired Event Code: %2 Description: %3
Storage Cell: %1 lastSafeChoiceDelay Expired Event Code: %2 Description: %3
Storage Cell: %1 crashDetectDelay Expired Event Code: %2 Description: %3
Storage Cell: %1 retSCCBNum not an SCCB Num Event Code: %2 Description: %3
Storage Cell: %1 Unable to read Copy1 of MLD Event Code: %2 Description: %3
Storage Cell: %1 Copy 1 of MLD Invalid Event Code: %2 Description: %3
Storage Cell: %1 Invalid Copy block of MLD Event Code: %2 Description: %3
Storage Cell: %1 Copy 2 of MLD Invalid Event Code: %2 Description: %3
Storage Cell: %1 MLD database capacity not equal to true MLD capacity Event Code:
%2 Description: %3
24028 88035ddc
24029 88035ddd
24030 88035dde
2
2
2
4028
4029
4030
Storage Cell: %1 Backup range out of bounds of copy 1 range Event Code: %2
Description: %3
Storage Cell: %1 MLD Manager Lock Crash DetectDelay has expired, just taking lock!
Event Code: %2 Description: %3
Storage Cell: %1 MLD Copy 1 Restored Event Code: %2 Description: %3
Storage Management Appliance Software Event Code Definitions Application Notes
63
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
24031 88035ddf
24032 88035de0
24033 88035de1
2
2
2
4031
4032
4033
Storage Cell: %1 MLD Copy 2 Restored Event Code: %2 Description: %3
Storage Cell: %1 Unable to find UidAssoc Object Event Code: %2 Description: %3
Storage Cell: %1 Unable to store UID Association Object Event Code: %2 Description:
%3
24034 88035de2
24035 88035de3
2
2
4034
4035
Storage Cell: %1 Unable to find UidAssoc Object Event Code: %2 Description: %3
Storage Cell: %1 Unable to read last Fusion event read Event Code: %2 Description:
%3
24036 88035de4
24037 88035de5
24038 88035de6
24039 88035de7
24040 88035de8
24041 88035de9
24042 88035dea
24043 88035deb
24044 88035dec
2
2
2
2
2
2
2
2
2
4036
4037
4038
4039
4040
4041
4042
4043
4044
Storage Cell: %1 MLD Notification Queue Empty Event Code: %2 Description: %3
Storage Cell: %1 Unable to find Notification Object Event Code: %2 Description: %3
Storage Cell: %1 Unable to store Notification Object Event Code: %2 Description: %3
Storage Cell: %1 Unable to find Notification Object Event Code: %2 Description: %3
Storage Cell: %1 Unable to read Event Log Pointer Event Code: %2 Description: %3
Storage Cell: %1 Unable to read Event Log Event Code: %2 Description: %3
Storage Cell: %1 Unable to store Event Log Event Code: %2 Description: %3
Storage Cell: %1 Unable to read Event Log Event Code: %2 Description: %3
Storage Cell: %1 Unable to read Event Log and free Lock Event Code: %2 Description:
%3
24045 88035ded
24046 88035dee
24047 88035def
24048 88035df0
24049 88035df1
2
2
2
2
2
4045
4046
4047
4048
4049
Storage Cell: %1 Unable to store Event Log and free Lock Event Code: %2 Description:
%3
Storage Cell: %1 Unable to read Event Log and free Lock Event Code: %2 Description:
%3
Storage Cell: %1 Previously Read Object Properties do not Match Event Code: %2
Description: %3
Storage Cell: %1 Previously Read Object Properties do not Match Event Code: %2
Description: %3
Storage Cell: %1 Unable to read Notification Host List Event Code: %2 Description:
%3
24050 88035df2
24051 88035df3
2
2
4050
4051
Storage Cell: %1 Unable to store Notification Host List Event Code: %2 Description: %3
Storage Cell: %1 Unable to store Notification Host List and free Lock Event Code: %2
Description: %3
24052 88035df4
24053 88035df5
24054 88035df6
2
2
2
4052
4053
4054
Storage Cell: %1 Unable to read Event Configuration List Event Code: %2 Description:
%3
Storage Cell: %1 Unable to store Event Configuration List Event Code: %2 Description:
%3
Storage Cell: %1 Unable to store Event Configuration List and free Lock Event Code: %2
Description: %3
24055 88035df7
24056 88035df8
24057 88035df9
24058 88035dfa
24059 88035dfb
25001 880361a9
25002 880361aa
2
2
2
2
2
2
2
4055
4056
4057
4058
4059
5001
5002
Storage Cell: %1 MLD roll up buffer full Event Code: %2 Description: %3
Storage Cell: %1 MLD roll up list read error Event Code: %2 Description: %3
Storage Cell: %1 MLD Monitor Lock error Event Code: %2 Description: %3
Storage Cell: %1 MLD Manager Mutex Timeout error Event Code: %2 Description: %3
Storage Cell: %1 MLD Manager list is empty Event Code: %2 Description: %3
Storage Cell: %1 Monitor Startup Complete Event Code: %2 Description: %3
Storage Cell: %1 Monitor Startup Failed Event Code: %2 Description: %3
64
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
25003 880361ab
25004 880361ac
25005 880361ad
25006 880361ae
25007 880361af
25008 880361b0
2
6
2
2
2
2
5003
5004
5005
5006
5007
5008
Storage Cell: %1 Monitor ShutDown Complete Event Code: %2 Description: %3
Storage Cell: %1 Monitor Memory Allocation Failure Event Code: %2 Description: %3
Storage Cell: %1 Monitor Mark Agent as Inactive Event Code: %2 Description: %3
Storage Cell: %1 Monitor create thread error Event Code: %2 Description: %3
Storage Cell: %1 Monitor create timer error Event Code: %2 Description: %3
Storage Cell: %1 Monitor agent registration - Complete Event Code: %2 Description:
%3
25009 880361b1
25010 880361b2
25011 880361b3
25012 880361b4
25013 880361b5
25014 880361b6
25015 880361b7
25016 880361b8
25017 880361b9
25018 880361ba
25019 880361bb
2
2
2
2
2
2
2
2
2
2
2
5009
5010
5011
5012
5013
5014
5015
5016
5017
5018
5019
Storage Cell: %1 Monitor controller rediscovery - Complete Event Code: %2
Description: %3
Storage Cell: %1 Monitor initiated a storage system shutdown because of controller
failure Event Code: %2 Description: %3
Storage Cell: %1 Unknown storage system rediscovery complete Event Code: %2
Description: %3
Storage Cell: %1 Start monitoring thread for storage system - Complete Event Code: %2
Description: %3
Storage Cell: %1 Start monitoring thread for storage system - Fail Event Code: %2
Description: %3
Storage Cell: %1 Monitoring thread for storage system terminated Event Code: %2
Description: %3
Storage Cell: %1 Rediscover unknown storage system - Error Event Code: %2
Description: %3
Storage Cell: %1 Controller time synchronized to appliance time. Event Code: %2
Description: %3
Storage Cell: %1 Appliance and controller time checked for synchronization. Event
Code: %2 Description: %3
Storage Cell: %1 Controller and appliance time are the same. No need to synchronize.
Event Code: %2 Description: %3
Storage Cell: %1 Exception caught in monitoring process. Event Code: %2 Description:
%3
26001 88036591
26002 88036592
26003 88036593
2
2
6
6001
6002
6003
Storage Cell: %1 Nsc Manager Ready Event Code: %2 Description: %3
Storage Cell: %1 Nsc Manager Index Out of Range Event Code: %2 Description: %3
Storage Cell: %1 Cannot access storage system. Communications error. Event Code:
%2 Description: %3
26004 88036594
26005 88036595
26006 88036596
2
2
6
6004
6005
6006
Storage Cell: %1 Nsc Manager No NSCs Found Event Code: %2 Description: %3
Storage Cell: %1 Nsc Manager Invalid Index Event Code: %2 Description: %3
Storage Cell: %1 Nsc Manager Memory Allocation Failure Event Code: %2
Description: %3
26007 88036597
26008 88036598
2
2
6007
6008
Storage Cell: %1 Nsc Manager No Physical Stores Found Event Code: %2 Description:
%3
Storage Cell: %1 Nsc Manager No Storage Cell Found Event Code: %2 Description:
%3
26009 88036599
26010 8803659a
26011 8803659b
2
2
2
6009
6010
6011
Storage Cell: %1 Nsc Manager No disk group Found Event Code: %2 Description: %3
Storage Cell: %1 Nsc Manager too many disk groups Event Code: %2 Description: %3
Storage Cell: %1 Nsc Manager No Volumes Found Event Code: %2 Description: %3
Storage Management Appliance Software Event Code Definitions Application Notes
65
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
26012 8803659c
2
6012
Storage Cell: %1 Nsc Manager No Logical Disks Found Event Code: %2 Description:
%3
26013 8803659d
2
6013
Storage Cell: %1 Nsc Manager Context Id Changed During Operation Event Code: %2
Description: %3
26014 8803659e
26015 8803659f
26016 880365a0
26017 880365a1
2
2
2
2
6014
6015
6016
6017
Storage Cell: %1 Nsc Manager No Name Event Code: %2 Description: %3
Storage Cell: %1 Nsc Manager Name Size Exceeded Event Code: %2 Description: %3
Storage Cell: %1 Nsc Manager Shutdown Complete Event Code: %2 Description: %3
Storage Cell: %1 Nsc Manager Mutex Creation Failure Event Code: %2 Description:
%3
26018 880365a2
26019 880365a3
26020 880365a4
2
2
2
6018
6019
6020
Storage Cell: %1 Nsc Manager Mutex Timeout Event Code: %2 Description: %3
Storage Cell: %1 Nsc Manager No MLD Handle Set Event Code: %2 Description: %3
Storage Cell: %1 Nsc Manager Failed Transport Layer Communication - No Such Id
Event Code: %2 Description: %3
26021 880365a5
26022 880365a6
2
2
2
2
2
2
2
2
6021
6022
6023
6024
6025
6026
6027
6028
Storage Cell: %1 Nsc Manager Failed Transport Layer Communication - TimeOut Event
Code: %2 Description: %3
Storage Cell: %1 Nsc Manager No Storage Cell Objects Found Event Code: %2
Description: %3
26023
26024
880365a7
880365a8
Storage Cell: %1 Nsc Manager No Attached Port Found Event Code: %2 Description:
%3
Storage Cell: %1 Nsc Manager Failed to get SCMI Object Handle Event Code: %2
Description: %3
26025 880365a9
26026 880365aa
Storage Cell: %1 Shutdown Both Restart And Power Off Requested Event Code: %2
Description: %3
Storage Cell: %1 Shutdown Drive Shelf Power Off But No Enclosure Power Off Requested
Event Code: %2 Description: %3
26027 880365ab
26028 880365ac
Storage Cell: %1 Shutdown Disable Battery But No Enclosure Power Off Requested
Event Code: %2 Description: %3
Storage Cell: %1 Shutdown Disable Battery But Shutdown Unconditional Requested
Event Code: %2 Description: %3
26029 880365ad
26030 880365ae
26031 880365af
26032 880365b0
26033 880365b1
2
2
2
2
2
6029
6030
6031
6032
6033
Storage Cell: %1 Shutdown Delay Out Of Range Event Code: %2 Description: %3
Storage Cell: %1 Cache Write Failure Event Code: %2 Description: %3
Storage Cell: %1 Battery Disable Failure Event Code: %2 Description: %3
Storage Cell: %1 Drive Shelf Disable Failure Event Code: %2 Description: %3
Storage Cell: %1 Battery Disable Failed on Both Controllers Batteries Event Code: %2
Description: %3
26034 880365b2
26035 880365b3
26036 880365b4
2
2
2
2
2
6034
6035
6036
6037
6038
Storage Cell: %1 Battery Disable Failed on This Controllers Battery Event Code: %2
Description: %3
Storage Cell: %1 Battery Disable Failed on the Other Controllers Battery Event Code:
%2 Description: %3
Storage Cell: %1 Requested disk failure protection level is set. Actual level will change
when sufficient disk space is available. Event Code: %2 Description: %3
26037
880365b5
Storage Cell: %1 Physical Store Contains Stale or Foreign Volume Information. Event
Code: %2 Description: %3
26038 880365b6
Storage Cell: %1 Controller Resynchronization or Reboot Occurred. Context Error Event
Code: %2 Description: %3
66
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
26039 880365b7
27001 88036979
2
2
2
2
2
2
6039
7001
7002
7003
7004
7005
Storage Cell: %1 Bad Command Or Response Cookie Event Code: %2 Description: %3
Storage Cell: %1 More than one storage system found Event Code: %2 Description: %3
Storage Cell: %1 Storage system already exists Event Code: %2 Description: %3
Storage Cell: %1 Storage System is not initialized Event Code: %2 Description: %3
Storage Cell: %1 Storage Object Mngr Ready Event Code: %2 Description: %3
27002
8803697a
27003 8803697b
27004 8803697c
27005 8803697d
Storage Cell: %1 Storage Object Mngr Shutdown Complete Event Code: %2
Description: %3
27006 8803697e
28001 88036d61
28002 88036d62
28003 88036d63
2
2
2
2
7006
8001
8002
8003
Storage Cell: %1 Storage system name too long Event Code: %2 Description: %3
Storage Cell: %1 Invalid Operation Event Code: %2 Description: %3
Storage Cell: %1 Storage system already created Event Code: %2 Description: %3
Storage Cell: %1 Controller already part of storage system configuration Event Code:
%2 Description: %3
28004 88036d64
28005 88036d65
2
2
8004
8005
Storage Cell: %1 Physical Store Count Below Minimum Event Code: %2 Description:
%3
Storage Cell: %1 Controller not part of storage system configuration Event Code: %2
Description: %3
28006 88036d66
28007 88036d67
28008 88036d68
28009 88036d69
28010 88036d6a
28011 88036d6b
28012 88036d6c
28013 88036d6d
28014 88036d6e
28015 88036d6f
28016 88036d70
28017 88036d71
28018 88036d72
28019 88036d73
28020 88036d74
28021 88036d75
28022 88036d76
28023 88036d77
28024 88036d78
28025 88036d79
2
3
3
3
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
8006
8007
8008
8009
8010
8011
8012
8013
8014
8015
8016
8017
8018
8019
8020
8021
8022
8023
8024
8025
Storage Cell: %1 Failed to uninitialize storage system Event Code: %2 Description: %3
Storage Cell: %1 Storage system File Open Error Event Code: %2 Description: %3
Storage Cell: %1 Storage system File Write Error Event Code: %2 Description: %3
Storage Cell: %1 Storage system File Read Error Event Code: %2 Description: %3
Storage Cell: %1 Name too long Event Code: %2 Description: %3
Storage Cell: %1 No String Error Event Code: %2 Description: %3
Storage Cell: %1 No MLD Handle Found Event Code: %2 Description: %3
Storage Cell: %1 No Controllers Found Event Code: %2 Description: %3
Storage Cell: %1 Controller Not Found On Loop Event Code: %2 Description: %3
Storage Cell: %1 No Disk Groups Found Event Code: %2 Description: %3
Storage Cell: %1 No Volumes Found Event Code: %2 Description: %3
Storage Cell: %1 No Physical Stores Found Event Code: %2 Description: %3
Storage Cell: %1 No Virtual Disks Found Event Code: %2 Description: %3
Storage Cell: %1 No Hosts Found Event Code: %2 Description: %3
Storage Cell: %1 Name already exists Event Code: %2 Description: %3
Storage Cell: %1 Folder is not empty Event Code: %2 Description: %3
Storage Cell: %1 Spares goal could not be met Event Code: %2 Description: %3
Storage Cell: %1 Storage system object found Event Code: %2 Description: %3
Storage Cell: %1 Storage system object not found Event Code: %2 Description: %3
Storage Cell: %1 New Physical Store Detected But Not Found In Physical Store List Event
Code: %2 Description: %3
28026 88036d7a
28027 88036d7b
28028 88036d7c
28029 88036d7d
3
3
3
6
8026
8027
8028
8029
Storage Cell: %1 MldManager Handle is NULL Event Code: %2 Description: %3
Storage Cell: %1 NscMngrInterface Handle is NULL Event Code: %2 Description: %3
Storage Cell: %1 ScLockMngr Handle is NULL Event Code: %2 Description: %3
Storage Cell: %1 Storage system initialization failed Event Code: %2 Description: %3
Storage Management Appliance Software Event Code Definitions Application Notes
67
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
28030 88036d7e
3
8030
Storage Cell: %1 MldMngr, NscMngrInterfaceMngr, or ScLockMngr Handle is NULL
Event Code: %2 Description: %3
28031 88036d7f
28032 88036d80
28033 88036d81
6
3
2
8031
8032
8033
Storage Cell: %1 Storage system initilization failed Event Code: %2 Description: %3
Storage Cell: %1 Storage system discovery failed Event Code: %2 Description: %3
Storage Cell: %1 Storage system already uninitialized or does not exist Event Code: %2
Description: %3
28034 88036d82
28035 88036d83
28036 88036d84
28037 88036d85
28038 88036d86
28039 88036d87
28040 88036d88
28041 88036d89
28042 88036d8a
28043 88036d8b
28044 88036d8c
28045 88036d8d
28046 88036d8e
28047 88036d8f
28048 88036d90
28049 88036d91
28050 88036d92
28051 88036d93
28052 88036d94
28053 88036d95
28054 88036d96
28055 88036d97
28056 88036d98
28057 88036d99
3
2
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
8034
8035
8036
8037
8038
8039
8040
8041
8042
8043
8044
8045
8046
8047
8048
8049
8050
8051
8052
8053
8054
8055
8056
8057
Storage Cell: %1 Get Total Storage Failed Event Code: %2 Description: %3
Storage Cell: %1 Storage system is uninitialized Event Code: %2 Description: %3
Storage Cell: %1 Get Total Storage Available Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Total Storage Occupied Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Total Storage Free Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Disk Group Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Disk Group List Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Disk Group Count Failed Event Code: %2 Description: %3
Storage Cell: %1 Create Volume Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Volume Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Volumes Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Volumes Count Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Virtual Disk Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Virtual Disk List Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Physical Store Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Physical Stores Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Physical Stores Count Failed Event Code: %2 Description: %3
Storage Cell: %1 Create Virtual Disk Failed Event Code: %2 Description: %3
Storage Cell: %1 Delete Virtual Disk Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Device Addition Policy Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Spares Current Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Spares Goal Failed Event Code: %2 Description: %3
Storage Cell: %1 Get storage system events failed Event Code: %2 Description: %3
Storage Cell: %1 Get Volume Replacement Delay Failed Event Code: %2 Description:
%3
28058 88036d9a
28059 88036d9b
28060 88036d9c
3
3
3
8058
8059
8060
Storage Cell: %1 Set Device Addition Policy Failed Event Code: %2 Description: %3
Storage Cell: %1 Set Spares Goal Failed Event Code: %2 Description: %3
Storage Cell: %1 Set Volume Replacement Delay Failed Event Code: %2 Description:
%3
28061 88036d9d
28062 88036d9e
28063 88036d9f
28064 88036da0
28065 88036da1
28066 88036da2
3
3
3
3
3
3
8061
8062
8063
8064
8065
8066
Storage Cell: %1 Create NSC Failed Event Code: %2 Description: %3
Storage Cell: %1 Update NSC Failed Event Code: %2 Description: %3
Storage Cell: %1 Create Host Failed Event Code: %2 Description: %3
Storage Cell: %1 Discard Host Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Host Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Host List Failed Event Code: %2 Description: %3
68
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
28067 88036da3
28068 88036da4
28069 88036da5
3
3
3
3
3
3
8067
8068
8069
8070
8071
8072
Storage Cell: %1 Get Host Count Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Presented Unit List Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Presented Unit Count Failed Event Code: %2 Description: %3
Storage Cell: %1 Free View Failed Event Code: %2 Description: %3
28070
88036da6
28071 88036da7
Storage Cell: %1 Storage system shutdown Failed Event Code: %2 Description: %3
28072
88036da8
Storage Cell: %1 StorageCell Virtual Disk Count Does Not Match Logical Disk Count
Event Code: %2 Description: %3
28073
28074
28075
88036da9
88036daa
88036dab
3
3
3
8073
8074
8075
Storage Cell: %1 Get Derived Unit List Failed Event Code: %2 Description: %3
Storage Cell: %1 Get Derived Unit Count Failed Event Code: %2 Description: %3
Storage Cell: %1 Get StorageCell Virtual Disk List Failed Event Code: %2 Description:
%3
28076
88036dac
3
3
8076
8077
Storage Cell: %1 Get StorageCell Virtual Disk Count Failed Event Code: %2
Description: %3
28077 88036dad
Storage Cell: %1 Error while building virtual disk root view Event Code: %2
Description: %3
28078
28079
88036dae
88036daf
3
3
8078
8079
Storage Cell: %1 Error while building host root view Event Code: %2 Description: %3
Storage Cell: %1 Error while uilding disk group root view Event Code: %2 Description:
%3
28080 88036db0
3
8080
Storage Cell: %1 Error while building hardware root view Event Code: %2 Description:
%3
28081 88036db1
28082 88036db2
3
3
8081
8082
Storage Cell: %1 Specified time format is incorrect Event Code: %2 Description: %3
Storage Cell: %1 Error creating/opening time syncronization file. Event Code: %2
Description: %3
28083 88036db3
28084 88036db4
29001 88037149
29002 8803714a
29003 8803714b
29004 8803714c
29005 8803714d
29006 8803714e
29007 8803714f
29008 88037150
29009 88037151
3
3
3
3
3
2
2
2
2
2
2
8083
8084
9001
9002
9003
9004
9005
9006
9007
9008
9009
Storage Cell: %1 StorageCell NscList Reordered. Event Code: %2 Description: %3
Storage Cell: %1 StorageCell NscList Mutex Get Error Event Code: %2 Description: %3
Storage Cell: %1 Virtual disk File Open Error Event Code: %2 Description: %3
Storage Cell: %1 Virtual disk File Write Error Event Code: %2 Description: %3
Storage Cell: %1 Virtual disk File Read Error Event Code: %2 Description: %3
Storage Cell: %1 Virtual disk name too long Event Code: %2 Description: %3
Storage Cell: %1 Virtual disk No String Error Event Code: %2 Description: %3
Storage Cell: %1 Virtual disk No Object Error Event Code: %2 Description: %3
Storage Cell: %1 Virtual disk still exists Event Code: %2 Description: %3
Storage Cell: %1 Virtual disk Invalid Value Event Code: %2 Description: %3
Storage Cell: %1 An outstanding command is still in progress for the virtual disk Event
Code: %2 Description: %3
29010 88037152
29011 88037153
29012 88037154
29013 88037155
2
2
2
2
9010
9011
9012
9013
Storage Cell: %1 Requested virtual disk size exceeds the available size Event Code: %2
Description: %3
Storage Cell: %1 Virtual disk size may be expanded but not reduced Event Code: %2
Description: %3
Storage Cell: %1 Operation on a fast virtual disk deletion completed Event Code: %2
Description: %3
Storage Cell: %1 Operation on a fast virtual disk creation completed Event Code: %2
Description: %3
Storage Management Appliance Software Event Code Definitions Application Notes
69
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
29014 88037156
2
9014
Storage Cell: %1 Operation on a fast virtual disk size expansion completed Event
Code: %2 Description: %3
29015 88037157
29016 88037158
29017 88037159
2
2
2
9015
9016
9017
Storage Cell: %1 Virtual disk cache data lost error Event Code: %2 Description: %3
Storage Cell: %1 Virtual disk data lost error resolved Event Code: %2 Description: %3
Storage Cell: %1 Operation rejected - The virtual disk has a sharing relationship with
another object Event Code: %2 Description: %3
29018 8803715a
29019 8803715b
29020 8803715c
29021 8803715d
29022 8803715e
29023 8803715f
2
2
2
2
2
2
9018
9019
9020
9021
9022
9023
Storage Cell: %1 Operation on this virtual disk was rejected due to the unit’s not normal
condition Event Code: %2 Description: %3
Storage Cell: %1 Operation on this virtual disk could only be performed if unit is
presented to a host Event Code: %2 Description: %3
Storage Cell: %1 Cache policies cannot be modified if unit is presented to a host Event
Code: %2 Description: %3
Storage Cell: %1 Allowed property changes successful. (Cache policy changes not
allowed, while virtual disk is presented to a host.) Event Code: %2 Description: %3
Storage Cell: %1 Requested redundancy type cannot be implemented with the current
disk group condition. Event Code: %2 Description: %3
Storage Cell: %1 Your unit was created but cannot be presented at this time. Continue to
check your unit and present it later when it is fully allocated. Event Code: %2
Description: %3
29024 88037160
2
9024
Storage Cell: %1 Operation would exceed the maximum allowable presented units.
Event Code: %2 Description: %3
29025 88037161
29026 88037162
2
2
9025
9026
Storage Cell: %1 Virtual Disk Device Data Lost Error Event Code: %2 Description: %3
Storage Cell: %1 The Most Significant Hex Character in a World Wide LUN Name must
be a 6 Event Code: %2 Description: %3
29027 88037163
29028 88037164
29029 88037165
2
2
2
9027
9028
9029
Storage Cell: %1 Virtual disk cache and inoperative data lost error Event Code: %2
Description: %3
Storage Cell: %1 Virtual disk inoperative data lost error Event Code: %2 Description:
%3
Storage Cell: %1 Virtual disk condition failed because of an inoperative data lost error.
Event Code: %2 Description: %3
30001 88037531
30002 88037532
30003 88037533
30004 88037534
30005 88037535
30006 88037536
30007 88037537
30008 88037538
30009 88037539
2
3
2
2
2
6
2
2
2
10001 Storage Cell: %1 Storage Object Broker Ready Event Code: %2 Description: %3
10002 Storage Cell: %1 Storage Object Startup Failed Event Code: %2 Description: %3
10003 Storage Cell: %1 Invalid storage system name Event Code: %2 Description: %3
10004 Storage Cell: %1 Storage system is not Initialized Event Code: %2 Description: %3
10005 Storage Cell: %1 Failed to set storage system name Event Code: %2 Description: %3
10006 Storage Cell: %1 SOB Memory Allocation Failure Event Code: %2 Description: %3
10007 Storage Cell: %1 Failed to find virtual disk from list Event Code: %2 Description: %3
10008 Storage Cell: %1 Failed to find host from list Event Code: %2 Description: %3
10009 Storage Cell: %1 The Lun specified for this Host is already in use Event Code: %2
Description: %3
30010 8803753a
30011 8803753b
2
2
10010 Storage Cell: %1 Your initialized system must have at least one disk group Event Code:
%2 Description: %3
10011 Storage Cell: %1 Cannot talk to all available NSCs Event Code: %2 Description: %3
70
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
30012 8803753c
30013 8803753d
30014 8803753e
30015 8803753f
30016 88037540
30017 88037541
2
2
2
2
2
2
10012 Storage Cell: %1 Command rejected - Folder is not empty Event Code: %2 Description:
%3
10013 Storage Cell: %1 Command rejected - There are virtual disk(s) attached to this disk
group Event Code: %2 Description: %3
10014 Storage Cell: %1 Command rejected - There are virtual disk(s) presented to this host
Event Code: %2 Description: %3
10015 Storage Cell: %1 Command rejected - The virtual disk has a sharing relationship with
another object Event Code: %2 Description: %3
10016 Storage Cell: %1 Target storage system is currently being used by another process Event
Code: %2 Description: %3
10017 Storage Cell: %1 Command rejected - Number of disk groups will exceed the maximum
allowable number Event Code: %2 Description: %3
30018 88037542
30019 88037543
30020 88037544
2
2
2
10018 Storage Cell: %1 Cannot access the password file Event Code: %2 Description: %3
10019 Storage Cell: %1 Enterprise Login - Complete Event Code: %2 Description: %3
10020 Storage Cell: %1 Operation rejected - Storage system should conform with the number
of minimum member devices. Event Code: %2 Description: %3
30021 88037545
30022 88037546
30023 88037547
30024 88037548
30025 88037549
30026 8803754a
30027 8803754b
2
2
2
2
2
2
2
10021 Storage Cell: %1 Rediscovery of controllers - Complete Event Code: %2 Description:
%3
10022 Storage Cell: %1 Unable to establish communication with controller, check all
connections. Event Code: %2 Description: %3
10023 Storage Cell: %1 Disk Group Data Lost Error Resolution Sequence 3 - Disk Group
Resolved to Normal Event Code: %2 Description: %3
10024 Storage Cell: %1 Disk Group Data Lost Error Resolution Sequence 1 - Marked Event
Code: %2 Description: %3
10025 Storage Cell: %1 Disk Group Data Lost Error Resolution Sequence 2 - Affected Units
Deleted Event Code: %2 Description: %3
10026 Storage Cell: %1 Disk Group Data Lost Error Resolution Sequence 3 - Disk Group
Deleted Event Code: %2 Description: %3
10027 Storage Cell: %1 Error - Creating the virtual disk would exceed the maximum allowable
count Event Code: %2 Description: %3
30028 8803754c
30029 8803754d
30030 8803754e
30031 8803754f
31001 88037919
31002 8803791a
31003 8803791b
2
2
2
2
2
2
6
10028 Storage Cell: %1 Volume Insufficient Resources Event Code: %2 Description: %3
10029 Storage Cell: %1 Process mutex is locked Event Code: %2 Description: %3
10030 Storage Cell: %1 Invalid URL request type Event Code: %2 Description: %3
10031 Storage Cell: %1 Invalid URL object type Event Code: %2 Description: %3
11001 Storage Cell: %1 Agent Startup Complete Event Code: %2 Description: %3
11002 Storage Cell: %1 AgentShutdown Complete Event Code: %2 Description: %3
11003 Storage Cell: %1 Insufficient memory to create a new object, Heap may be full! Event
Code: %2 Description: %3
31004 8803791c
32000 88037d00
32001 88037d01
6
2
2
11004 Storage Cell: %1 Agent Startup Failed Event Code: %2 Description: %3
12000 Storage Cell: %1 Nsc Manager Interface First Status Event Code: %2 Description: %3
12001 Storage Cell: %1 Nsc Manager Interface No NSCs Found Event Code: %2 Description:
%3
32002 88037d02
2
12002 Storage Cell: %1 Nsc Manager Interface Index Out Of Range Event Code: %2
Description: %3
Storage Management Appliance Software Event Code Definitions Application Notes
71
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
32003 88037d03
32004 88037d04
32005 88037d05
32007 88037d07
32008 88037d08
2
2
2
2
2
12003 Storage Cell: %1 Unable to process command at this time. Retry the command or check
all connections. Event Code: %2 Description: %3
12004 Storage Cell: %1 Nsc Manager Interface Initialization Complete Event Code: %2
Description: %3
12005 Storage Cell: %1 Nsc Manager Interface Initialization Failed Event Code: %2
Description: %3
12007 Storage Cell: %1 Lock description not null but failed to get context ID Event Code: %2
Description: %3
12008 Storage Cell: %1 No Disk Groups Available For Access Event Code: %2 Description:
%3
33001 880380e9
33002 880380ea
33003 880380eb
33004 880380ec
33005 880380ed
33006 880380ee
33007 880380ef
33008 880380f0
33009 880380f1
33010 880380f2
33011 880380f3
33012 880380f4
2
2
2
2
6
2
6
6
6
2
3
2
13001 Storage Cell: %1 NM Good Status Event Code: %2 Description: %3
13002 Storage Cell: %1 Notification Mngr Online Event Code: %2 Description: %3
13003 Storage Cell: %1 Notification Mngr Offline Event Code: %2 Description: %3
13004 Storage Cell: %1 NM Startup Complete Event Code: %2 Description: %3
13005 Storage Cell: %1 NM Startup Failed Event Code: %2 Description: %3
13006 Storage Cell: %1 Notification Succeeded Event Code: %2 Description: %3
13007 Storage Cell: %1 Notification Failed Event Code: %2 Description: %3
13008 Storage Cell: %1 Notification Failed - MLD Error Event Code: %2 Description: %3
13009 Storage Cell: %1 Notification Failed - Network Error Event Code: %2 Description: %3
13010 Storage Cell: %1 NM Shutdown Complete Event Code: %2 Description: %3
13011 Storage Cell: %1 NM Shutdown Failed Event Code: %2 Description: %3
13012 Storage Cell: %1 NM Prev Failed Notification Successfully Notified Event Code: %2
Description: %3
33013 880380f5
33014 880380f6
33015 880380f7
33016 880380f8
33017 880380f9
34001 880384d1
34002 880384d2
34003 880384d3
34004 880384d4
34005 880384d5
2
2
6
2
6
2
2
2
2
2
13013 Storage Cell: %1 NM SNMP Manager Online Event Code: %2 Description: %3
13014 Storage Cell: %1 NM SNMP Packet Sent Event Code: %2 Description: %3
13015 Storage Cell: %1 NM SNMP Packet Failed Event Code: %2 Description: %3
13016 Storage Cell: %1 NM SNMP Manager Offline Event Code: %2 Description: %3
13017 Storage Cell: %1 NM Memory Allocation Error Event Code: %2 Description: %3
14001 Storage Cell: %1 View Already Exists Event Code: %2 Description: %3
14002 Storage Cell: %1 View Is Not Set Event Code: %2 Description: %3
14003 Storage Cell: %1 No View Object(s) Found Event Code: %2 Description: %3
14004 Storage Cell: %1 View Index Is Out Of Range Event Code: %2 Description: %3
14005 Storage Cell: %1 View Object - Invalid Object Condition Event Code: %2 Description:
%3
34006 880384d6
34007 880384d7
34008 880384d8
34009 880384d9
34010 880384da
34011 880384db
34012 880384dc
34013 880384dd
2
3
3
2
2
2
2
2
14006 Storage Cell: %1 View Object - Invalid Object Type Event Code: %2 Description: %3
14007 Storage Cell: %1 View List Pointer is NULL Event Code: %2 Description: %3
14008 Storage Cell: %1 View Object Pointer is NULL Event Code: %2 Description: %3
14009 Storage Cell: %1 Building View List Object - Complete Event Code: %2 Description: %3
14010 Storage Cell: %1 Building View List Object - Failed Event Code: %2 Description: %3
14011 Storage Cell: %1 View Size is Zero Event Code: %2 Description: %3
14012 Storage Cell: %1 View Find by UID Failed Event Code: %2 Description: %3
14013 Storage Cell: %1 View Find by Type Failed Event Code: %2 Description: %3
72
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
34014 880384de
34015 880384df
34016 880384e0
34017 880384e1
34018 880384e2
35001 880388b9
35002 880388ba
35003 880388bb
35004 880388bc
35005 880388bd
35006 880388be
2
2
2
2
2
2
2
2
2
2
2
14014 Storage Cell: %1 View Find by Index Failed Event Code: %2 Description: %3
14015 Storage Cell: %1 View Find by Name Failed Event Code: %2 Description: %3
14016 Storage Cell: %1 View Find by WWN Failed Event Code: %2 Description: %3
14017 Storage Cell: %1 View Find by Type by Name Failed Event Code: %2 Description: %3
14018 Storage Cell: %1 View Find by Name by Type Failed Event Code: %2 Description: %3
15001 Storage Cell: %1 Tree View Symbol Not Found Event Code: %2 Description: %3
15002 Storage Cell: %1 Tree View Id Symbol Not Found Event Code: %2 Description: %3
15003 Storage Cell: %1 Tree Cursor Symbol Not Found Event Code: %2 Description: %3
15004 Storage Cell: %1 Tree Cursor Id Symbol Not Found Event Code: %2 Description: %3
15005 Storage Cell: %1 Tree Sibling Symbol Not Found Event Code: %2 Description: %3
15006 Storage Cell: %1 Tree Total Children Symbol Not Found Event Code: %2 Description:
%3
35007 880388bf
35008 880388c0
35009 880388c1
36001 88038ca1
2
2
2
2
15007 Storage Cell: %1 Tree Expansion Symbol Not Found Event Code: %2 Description: %3
15008 Storage Cell: %1 Tree Contraction Symbol Not Found Event Code: %2 Description: %3
15009 Storage Cell: %1 Tree Invalid Descriptor String Event Code: %2 Description: %3
16001 Storage Cell: %1 Ema Short Status - Reissue Command Event Code: %2 Description:
%3
36002 88038ca2
36003 88038ca3
36004 88038ca4
2
2
2
16002 Storage Cell: %1 Ema EMU Could Not Read ALPA Event Code: %2 Description: %3
16003 Storage Cell: %1 Ema Invalid Request Event Code: %2 Description: %3
16004 Storage Cell: %1 Ema Invalid Handle Set In Request Packet Event Code: %2
Description: %3
36005 88038ca5
2
16005 Storage Cell: %1 Ema No Pstore At Referenced Location Event Code: %2 Description:
%3
36006 88038ca6
36007 88038ca7
2
2
16006 Storage Cell: %1 Ema No Primary EMU Selected Event Code: %2 Description: %3
16007 Storage Cell: %1 Ema Invalid SubEnclosure ID Specified Event Code: %2 Description:
%3
36008 88038ca8
36009 88038ca9
2
2
16008 Storage Cell: %1 Ema No Device Found Event Code: %2 Description: %3
16009 Storage Cell: %1 Ema Request Packet Missing Parameter Event Code: %2 Description:
%3
36010 88038caa
36011 88038cab
2
2
16010 Storage Cell: %1 Ema Could Not Find SubEnclosure in Configuration List Event Code:
%2 Description: %3
16011 Storage Cell: %1 Ema EMU Alarm Or Status Event Information Event Code: %2
Description: %3
36012 88038cac
36013 88038cad
2
2
16012 Storage Cell: %1 Ema Non-specific error occurred Event Code: %2 Description: %3
16013 Storage Cell: %1 Ema Shelf WWN Could Not Be Accessed Through A Drive Event
Code: %2 Description: %3
36014 88038cae
36015 88038caf
36016 88038cb0
2
2
2
16014 Storage Cell: %1 Ema EMU Failed To Enter Primary Mode Event Code: %2
Description: %3
16015 Storage Cell: %1 Ema EMU Failed To Exit Primary Mode Event Code: %2 Description:
%3
16016 Storage Cell: %1 Ema Downloaded File Does Not Contain Valid Fibre Channel Loader
[status:1] Event Code: %2 Description: %3
Storage Management Appliance Software Event Code Definitions Application Notes
73
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
36017 88038cb1
36018 88038cb2
36019 88038cb3
2
2
2
16017 Storage Cell: %1 Ema Downloaded File Format Is Not Recognized [status:2] Event
Code: %2 Description: %3
16018 Storage Cell: %1 Ema Incorrect Firmware In Downloaded File [status:3] Event Code: %2
Description: %3
16019 Storage Cell: %1 Ema Downloaded Loader is Too Large [status:4] Event Code: %2
Description: %3
36020 88038cb4
36021 88038cb5
2
2
16020 Storage Cell: %1 Ema Invalid Checksum [status:5] Event Code: %2 Description: %3
16021 Storage Cell: %1 Ema Previous Offset Plus Previous Length Not Equal To Current Offset
[status:6] Event Code: %2 Description: %3
36022 88038cb6
36023 88038cb7
36024 88038cb8
36025 88038cb9
36026 88038cba
36027 88038cbb
36028 88038cbc
36029 88038cbd
36030 88038cbe
36031 88038cbf
36032 88038cc0
36033 88038cc1
36034 88038cc2
36035 88038cc3
36036 88038cc4
36037 88038cc5
36038 88038cc6
36039 88038cc7
2
2
2
2
2
2
2
2
2
2
2
6
2
2
2
2
2
2
16022 Storage Cell: %1 Ema Downloaded Loader Terminated Incorrectly [status:7] Event
Code: %2 Description: %3
16023 Storage Cell: %1 Ema EMU Out Of Memory [status:8] Event Code: %2 Description:
%3
16024 Storage Cell: %1 Ema EMU CDB Timeout -- Download Aborted [status:9] Event Code:
%2 Description: %3
16025 Storage Cell: %1 Ema EMU Internal State Machine Error [status:10] Event Code: %2
Description: %3
16026 Storage Cell: %1 Ema EMU Flash Erasure Failure [status:11] Event Code: %2
Description: %3
16027 Storage Cell: %1 Ema EMU In Primary Mode - Cannot Download To Primary EMU
[status:12] Event Code: %2 Description: %3
16028 Storage Cell: %1 Ema Previous Offset Plus Previous Length Greater Than Total Size
[status:13] Event Code: %2 Description: %3
16029 Storage Cell: %1 Ema Current Total Size Different From Previous Total Size [status:14]
Event Code: %2 Description: %3
16030 Storage Cell: %1 Ema Could Not Restore Reporting Group Number. Final Download
Record Error Event Code: %2 Description: %3
16031 Storage Cell: %1 Ema Could Not Recovery From Invop. Invop Retries Exhausted Event
Code: %2 Description: %3
16032 Storage Cell: %1 Ema Requested WWN Does Not Match Enclosure WWN Event
Code: %2 Description: %3
16033 Storage Cell: %1 Ema EMU Enclosure Services Error Occurred. EMU May Be
Unavailable or Not Installed Event Code: %2 Description: %3
16034 Storage Cell: %1 Ema SCSI Error Occurred While Trying To Communicate With EMU
Event Code: %2 Description: %3
16035 Storage Cell: %1 Ema Could Not Open EMU Firmware File Event Code: %2
Description: %3
16036 Storage Cell: %1 Ema EMU Firmware File Name Is Null Event Code: %2 Description:
%3
16037 Storage Cell: %1 Ema EMU Firmware Download Retries Exhausted. Manual Download
May Be Required Event Code: %2 Description: %3
16038 Storage Cell: %1 Ema EMU Current Firmware Version Matches Upgrade Firmware
Version. No Upgrade Will Be Performed. Event Code: %2 Description: %3
16039 Storage Cell: %1 Ema EMU Firmware Upgrade Success Event Code: %2 Description:
%3
74
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
36040 88038cc8
2
2
2
2
2
2
2
6
3
3
16040 Storage Cell: %1 Ema EMU In Load State. Do Not Power Off. Reload EMU Firmware
Event Code: %2 Description: %3
37001 88039089
17001 Storage Cell: %1 Drive Code Load Descriptor File Open Error Event Code: %2
Description: %3
37002
37003
8803908a
8803908b
17002 Storage Cell: %1 Drive Code Load Descriptor File Parsing Error - Invalid Line Event
Code: %2 Description: %3
17003 Storage Cell: %1 Drive Code Load Image File Open Error, Event Code: %2
Description: %3
37004 8803908c
37005 8803908d
37006 8803908e
37007 8803908f
37008 88039090
37009 88039091
17004 Storage Cell: %1 Drive Code Load Image File Error Getting File Size Event Code: %2
Description: %3
17005 Storage Cell: %1 Drive Code Load Image File Buffer Allocation Error Event Code: %2
Description: %3
17006 Storage Cell: %1 Drive Code Load Image File Read Error Event Code: %2 Description:
%3
17007 Storage Cell: %1 Drive Code Load Drive Firmware Update Failed Event Code: %2
Description: %3
17008 Storage Cell: %1 Drive Code Load Drive Inquiry Failed Event Code: %2 Description:
%3
17009 Storage Cell: %1 Drive Code Load Format Command Failed Event Code: %2
Description: %3
37010 88039092
37011 88039093
3
3
17010 Storage Cell: %1 Drive Code Load Format Failed Event Code: %2 Description: %3
17011 Storage Cell: %1 Drive Code Load Restore Volume Failed Event Code: %2 Description:
%3
37012 88039094
37013 88039095
37014 88039096
2
2
3
17012 Storage Cell: %1 Drive Code Load Get Physical Store Condition Failed Event Code: %2
Description: %3
17013 Storage Cell: %1 Drive Code Load Get Volume Condition Failed Event Code: %2
Description: %3
17014 Storage Cell: %1 Drive Code Load Drive Spin Up Error Event Code: %2 Description:
%3
37015 88039097
37016 88039098
2
2
17015 Storage Cell: %1 Drive Code Load - Complete Event Code: %2 Description: %3
17016 Storage Cell: %1 Drive Code Load Disk Group Migration In Progress Event Code: %2
Description: %3
37017 88039099
2
17017 Storage Cell: %1 Drive Code Load Unable To Code Load Disks Part Of A Group Event
Code: %2 Description: %3
38001 88039471
38002 88039472
38003 88039473
38004 88039474
38005 88039475
38006 88039476
38007 88039477
38008 88039478
38009 88039479
38010 8803947a
2
2
2
2
2
2
2
2
2
2
18001 Storage Cell: %1 Api Created Element Success Event Code: %2 Description: %3
18002 Storage Cell: %1 Api Created Storage Success Event Code: %2 Description: %3
18003 Storage Cell: %1 Api Created Storage Client Success Event Code: %2 Description: %3
18004 Storage Cell: %1 Api Set Storage Success Event Code: %2 Description: %3
18005 Storage Cell: %1 Api Set Element Success Event Code: %2 Description: %3
18006 Storage Cell: %1 Api Deleted Element Success Event Code: %2 Description: %3
18007 Storage Cell: %1 Api Deleted Storage Success Event Code: %2 Description: %3
18008 Storage Cell: %1 Api Deleted Storage Client Success Event Code: %2 Description: %3
18009 Storage Cell: %1 Api Created Snapshot Success
18010 Storage Cell: %1 Api Created Clone Success Event Code: %2 Description: %3
Storage Management Appliance Software Event Code Definitions Application Notes
75
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
38018 88039482
38019 88039483
38022 88039486
38024 88039488
38025 88039489
38028 8803948c
38034 88039492
2
2
2
2
2
2
2
18018 Storage Cell: %1 Api Unable To Get The Lock Event Code: %2 Description: %3
18019 Storage Cell: %1 Api Created PresentedUnit Success Event Code: %2 Description: %3
18022 Storage Cell: %1 Api Create DiskGroup Success Event Code: %2 Description: %3
18024 Storage Cell: %1 Api Create Folder Success Event Code: %2 Description: %3
18025 Storage Cell: %1 Api Delete Folder Success Event Code: %2 Description: %3
18028 Storage Cell: %1 Api Set Folder Success Event Code: %2 Description: %3
18034 Storage Cell: %1 Api Invalid User Name Or Password Error Event Code: %2
Description: %3
38036 88039494
38038 88039496
2
2
18036 Storage Cell: %1 Api Delete Presented Unit Success Event Code: %2 Description: %3
18038 Storage Cell: %1 Api Set Diskgroup Success
Description: %3
Event Code: %2
38039 88039497
38040 88039498
38041 88039499
38042 8803949a
2
2
2
2
18039 Storage Cell: %1 Api Set Disk Success Event Code: %2 Description: %3
18040 Storage Cell: %1 Api Delete Storage Family Success Event Code: %2 Description: %3
18041 Storage Cell: %1 Api Set Storage Family Success Event Code: %2 Description: %3
18042 Storage Cell: %1 Api Control Memory Allocation Failure Event Code: %2 Description:
%3
38045 8803949d
38047 8803949f
38048 880394a0
38049 880394a1
38050 880394a2
38051 880394a3
38052 880394a4
38059 880394ab
38060 880394ac
38063 880394af
2
2
2
2
2
2
2
2
2
2
18045 Storage Cell: %1 Api Element Codeload Success
Event Code: %2 Description: %3
18047 Storage Cell: %1 Api Disk Codeload Success Event Code: %2 Description: %3
18048 Storage Cell: %1 Api Monitor Codeload Success Event Code: %2 Description: %3
18049 Storage Cell: %1 Api Added Port WwID Success Event Code: %2 Description: %3
18050 Storage Cell: %1 Api Set Storage Client Success Event Code: %2 Description: %3
18051 Storage Cell: %1 Api Invalid Operation Event Code: %2 Description: %3
18052 Storage Cell: %1 Api Deleted Port WwID Success Event Code: %2 Description: %3
18059 Storage Cell: %1 Api Set Power Success Event Code: %2 Description: %3
18060 Storage Cell: %1 Api Element Is Not Initialized Event Code: %2 Description: %3
18063 Storage Cell: %1 Api Error trying to delete a disk group Event Code: %2 Description:
%3
38065 880394b1
38066 880394b2
38067 880394b3
38068 880394b4
2
2
2
2
2
2
2
2
18065 Storage Cell: %1 Api A storage (virtual disk) operation is in progress. Try again later.
Event Code: %2 Description: %3
18066 Storage Cell: %1 Api The storage (virtual disk) condition is invalid. The storage may be
in error. Try again later. Event Code: %2 Description: %3
18067 Storage Cell: %1 Api Error calling get virtual disk condition. Virtual disk may be deleted.
Try again later. Event Code: %2 Description: %3
18068 Storage Cell: %1 Api Invalid initialization of the API. Cannot start monitoring process
which limits storage cell actions. Event Code: %2 Description: %3
38070
880394b6
18070 Storage Cell: %1 Api A command is currently under execution from another API call. Try
again later. Event Code: %2 Description: %3
38071 880394b7
18071 Storage Cell: %1 Api The server has not completed initialization, cannot process the
request. Event Code: %2 Description: %3
38073
38074
880394b9
880394ba
18073 Storage Cell: %1 Api Removing of disk from disk group successfull Event Code: %2
Description: %3
18074 Storage Cell: %1 Api Adding of disk(s) to disk group successfull Event Code: %2
Description: %3
76
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
38075
880394bb
2
2
2
18075 Storage Cell: %1 Api Modify monitor properties successfull Event Code: %2
Description: %3
38076
880394bc
18076 Storage Cell: %1 Api Element name too long. Maximum is 20 characters. Event Code:
%2 Description: %3
38079 880394bf
38080 880394c0
38081 880394c1
38082 880394c2
18079 Storage Cell: %1 Api The basic license cannot be validated. Either the license key has
not been entered, or there is a system communication failure. Event Code: %2
Description: %3
2
2
2
18080 Storage Cell: %1 Api The snapshot/Snapclone license cannot be validated. Either the
license key has not been entered, or there is a system communication failure. Event
Code: %2 Description: %3
18081 Storage Cell: %1 Api The folder operation is not valid for the specified folder. Either the
folder is a root folder and cannot be modified, or it is a disk group folder for which you
should use ‘set group’ command. Event Code: %2 Description: %3
18082 Storage Cell: %1 Api Cannot create the clone copy because the target storage is not
presented. Event Code: %2 Description: %3
39001 88039859
39002 8803985a
39003 8803985b
3
2
2
19001 Storage Cell: %1 Storage Cell Lock Error Event Code: %2 Description: %3
19002 Storage Cell: %1 Storage Cell Deleted Event Code: %2 Description: %3
19003 Storage Cell: %1 An outstanding command is in-progress for the selected storage
system. Please try again later. Event Code: %2 Description: %3
39004 8803985c
39005 8803985d
39006 8803985e
39007 8803985f
39008 88039860
39009 88039861
39010 88039862
2
2
2
2
3
3
6
19004 Storage Cell: %1 Lock Wait Time too large Event Code: %2 Description: %3
19005 Storage Cell: %1 Place Request In Q Failed Event Code: %2 Description: %3
19006 Storage Cell: %1 No Match for Q Found Event Code: %2 Description: %3
19007 Storage Cell: %1 Agent Wait Timeout Event Code: %2 Description: %3
19008 Storage Cell: %1 Free Lock Unsuccessful Event Code: %2 Description: %3
19009 Storage Cell: %1 Lock Manager Mutex Timeout Error Event Code: %2 Description: %3
19010 Storage Cell: %1 Lock Queue Memory Allocation Failure Event Code: %2 Description:
%3
40001 88039c41
40002 88039c42
40003 88039c43
40004 88039c44
40005 88039c45
40011 88039c4b
40012 88039c4c
6
2
6
2
3
3
3
20001 Storage Cell: %1 LicMngr Memory Allocation Failure Event Code: %2 Description: %3
20002 Storage Cell: %1 LicMngr Startup Complete Event Code: %2 Description: %3
20003 Storage Cell: %1 LicMngr Startup Failed Event Code: %2 Description: %3
20004 Storage Cell: %1 License successfully checked out Event Code: %2 Description: %3
20005 Storage Cell: %1 License checkout failed Event Code: %2 Description: %3
20011 Storage Cell: %1 License Line has an incorrect format Event Code: %2 Description: %3
20012 Storage Cell: %1 License file with this Node WWID is missing Event Code: %2
Description: %3
40013 88039c4d
40014 88039c4e
40015 88039c4f
6
6
3
20013 Storage Cell: %1 License Library runtime error Event Code: %2 Description: %3
20014 Storage Cell: %1 New License Job invocation failed Event Code: %2 Description: %3
20015 Storage Cell: %1 Failed to retrieve Node WWN from storage system Event Code: %2
Description: %3
40016 88039c50
3
20016 Storage Cell: %1 Failed to retrieve license list from MLD Event Code: %2 Description:
%3
40017 88039c51
40018 88039c52
3
3
20017 Storage Cell: %1 Failed to write license list to MLD Event Code: %2 Description: %3
20018 Storage Cell: %1 This license line appears to be invalid Event Code: %2 Description:
%3
Storage Management Appliance Software Event Code Definitions Application Notes
77
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
40019 88039c53
40020 88039c54
40021 88039c55
40022 88039c56
40023 88039c57
41001 8803a029
41002 8803a02a
41003 8803a02b
41004 8803a02c
41005 8803a02d
41006 8803a02e
41007 8803a02f
41008 8803a030
41009 8803a031
41010 8803a032
41011 8803a033
41012 8803a034
41013 8803a035
41014 8803a036
41015 8803a037
41016 8803a038
41017 8803a039
42001 8803a411
3
6
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
2
3
20019 Storage Cell: %1 MLD Manager Handle is NULL - unable to update MLD License List
Event Code: %2 Description: %3
20020 Storage Cell: %1 LicMngr: StorageCell Handle is NULL Event Code: %2 Description:
%3
20021 Storage Cell: %1 The license you entered is a valid license but not for the Node WWN
on this controller pair Event Code: %2 Description: %3
20022 Storage Cell: %1 Function name string is null or in an incorrect format Event Code: %2
Description: %3
20023 Storage Cell: %1 Version string is null or in an incorrect format Event Code: %2
Description: %3
21001 Storage Cell: %1 HSV Upgrade Manager Image File Open Error Event Code: %2
Description: %3
21002 Storage Cell: %1 HSV Upgrade Manager Image File Buffer Allocation Error Event
Code: %2 Description: %3
21003 Storage Cell: %1 HSV Upgrade Manager Image File Read Error Event Code: %2
Description: %3
21004 Storage Cell: %1 HSV Upgrade Manager Event File Write Error Event Code: %2
Description: %3
21005 Storage Cell: %1 HSV Upgrade Manager Drive Firmware Update Failed Event Code:
%2 Description: %3
21006 Storage Cell: %1 HSV Upgrade Manager Global Header Edc Compute Error Event
Code: %2 Description: %3
21007 Storage Cell: %1 HSV Upgrade Manager Image Header Edc Compute Error Event
Code: %2 Description: %3
21008 Storage Cell: %1 HSV Upgrade Manager Image Type Exceeds Max Image Count Event
Code: %2 Description: %3
21009 Storage Cell: %1 HSV Upgrade Manager Image Type Not Controller Image Event
Code: %2 Description: %3
21010 Storage Cell: %1 HSV Upgrade Manager Image Size Exceeded Event Code: %2
Description: %3
21011 Storage Cell: %1 HSV Upgrade Manager Event File Open Error Event Code: %2
Description: %3
21012 Storage Cell: %1 HSV Upgrade Manager Image Edc Compute Error Event Code: %2
Description: %3
21013 Storage Cell: %1 HSV Upgrade Manager Begin Text Not Found Event Code: %2
Description: %3
21014 Storage Cell: %1 HSV Upgrade Manager After Text Not Found Event Code: %2
Description: %3
21015 Storage Cell: %1 HSV Upgrade Manager File Format Version Mismatch Event Code:
%2 Description: %3
21016 Storage Cell: %1 HSV Upgrade Manager Global Header Format Version Mismatch
Event Code: %2 Description: %3
21017 Storage Cell: %1 HSV Upgrade Manager Product Information Was Not Found Event
Code: %2 Description: %3
22001 Storage Cell: %1 Trace: Unable to write managment agent trace file Event Code: %2
Description: %3
78
Storage Management Appliance Software Event Code Definitions Application Notes
HSV Element Manager Event Codes
Table 9: HSV Element Manager Event Codes: Management Agent Events (Continued)
Event
ID
Event
Code
Sev-
erity
Evt.
No.
Description
42002 8803a412
43002 8803a7fa
43003 8803a7fb
2
3
6
22002 Storage Cell: %1 Trace: file write succeeded Event Code: %2 Description: %3
23002 Storage Cell: %1 Diagnostic The view list has errors Event Code: %2 Description: %3
23003 Storage Cell: %1 Diagnostic Memory allocation failure Event Code: %2 Description:
%3
Storage Management Appliance Software Event Code Definitions Application Notes
79
HSV Element Manager Event Codes
80
Storage Management Appliance Software Event Code Definitions Application Notes
|